  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 244 (2000), S. 501-506 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The boundary conditions in which Poisson statistics can be applied in nuclear spectrometry are investigated. Improved formulas for the uncertainty of nuclear counting with deadtime and pulse pileup are presented. A comparison is made between the expected statistical uncertainty for loss-free counting, fixed live-time and fixed real-time measurements.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 245 (2000), S. 199-203 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The k 0 and Q 0 values for 94Zr(n,γ)95Zr(E γ = 724.2+756.7 keV) and 96Zr(n,γ)97Zr(β−) 97mNb (E γ = 743.4 keV) were re-investigated. The aim was to further improve the reliability of the neutron spectrum characterization (f and α monitoring) in k 0-NAA, based on "bare monitor" methods with the use of these Zr radionuclides. So as to achieve this goal, experimental determinations were performed in three reactor centers: KFKI AEKI, Budapest (WWR-M reactor); INW, Gent (THETIS reactor); SCK·CEN, Mol (BR1 reactor). The results were: Q 0(94Zr) = 5.306; Q 0(96Zr) = 251.6; k 0(95Zr, 724.2+756.7 keV) = 2.000E-4; k 0(97Zr/97mNb, 743.4 keV) = 1.237E-5. This means that the newly evaluated k 0-values are about 4.7% lower than the formerly reported ones. It is also emphasized that the 97Zr half-life is 16.74 hours, contrary to the ∼1% higher values usually reported.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 245 (2000), S. 195-197 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The concepts of the Guide to the expression of Uncertainties in Measurements for chemical measurements (GUM) and the recommendations of the Eurachem document "Quantifying Uncertainty in Analytical Methods" are applied to set up the uncertainty budget for k 0-NAA. The "universally applicable spreadsheet technique", described by Kragten, is applied to the k 0-NAA basic equations for the computation of uncertainties. The variance components — individual standard uncertainties — highlight the contribution and the importance of the different parameters to be taken into account.
    Type of Medium: Electronic Resource