ISSN:
0935-6304
Keywords:
PAN
;
peroxyacetyl nitrate
;
alkyl nitrate
;
chlorinated hydrocarbons
;
halocarbons
;
capillary GC-ECD
;
Chemistry
;
Analytical Chemistry and Spectroscopy
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
Notes:
---A cryogenic preconcentration/high-resolution gas chromatographic technique has been developed for the rapid, simultaneous quantitation of C1-C4 organic nitrates and halocarbons in ambient air. Whole-air samples are collected in TedlarTM bags by an evacuated-chamber method. Samples were stable in 0.010-cm-thick bags for 24 h if they were immediately stored in a freezer at -25°C. Analytes in a 50-cm3 air sample were efficiently preconcentrated on fused-silica beads at -180°C and thermally desorbed at 30°C. High-resolution gas chromatography with a cross-linked polydimethylsiloxane fused-silica capillary column and an electron-capture detector were used for separation and quantitation of the analytes. An analysis time of about 12 min was facilitated by sample cryofocusing at -180°C and oven temperature programming. Recoveries of the analytes by the evacuated-chamber method were better than 95%. The sensitivity of the technique for sample volumes of 50 cm3 is in the sub-parts-per-trillion by volume (ppt[v]) range for many of the analytes, with an average precision of about ±5% for analytes at levels of about 10 ppt(v).
Additional Material:
4 Ill.