Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0584
    Keywords: Polycythemia vera ; Interferon ; Translocation, IgA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A patient with polycythemia vera associated with chromosomal translocation (6; 8) (q27; p11) and IgA monoclonal gammopathy was treated with interferon α-2b. Interferon α-2b induced good hematological control and reduced only IgA levels, but not IgG and IgM levels. In addition, cytogenetic improvement was obtained, the abnormal cells with chromosomal translocation declining from 100% to 50%. Interferon a may have selective effects on a malignant clone in polycythemia vera.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-2965
    Keywords: Key words:Bone density – Hip fracture – Osteoporosis – Quantitative ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract: The incidence of osteoporotic hip fracture increases in postmenopausal women with low hip bone mineral density (BMD). Dual X-ray absorptiometry (DXA) is the most commonly used technique for the assessment of bone status and provides good measurement precision. However, DXA affords little information about bone architecture. Quantitative ultrasound (QUS) systems have been developed to evaluate bone status for assessment of fracture risk. Our study was designed to assess a new QUS system from Hologic, the Sahara; to compare it with a previous model, the Walker-Sonix UBA 575+; and to investigate whether it is able to discriminate between women with and without fracture. Using both ultrasound devices, the measurements were performed at the heels of 33 postmenopausal women who had recently sustained hip fracture. A control group of 35 age-matched postmenopausal women was recruited for comparison. The total, neck and trochanter femoral BMD values were assessed using DXA for both groups. QUS and DXA measurements were significantly lower in fractured patients (p〈0.005) than in the control group. The short-term, mid-term and standardized short-term precisions were used to evaluate the reproducibility of the two QUS systems. The Sahara showed a better standardized coefficient of variation for broadband ultrasound attenuation (BUA) than did the UBA 575+ (p〈0.001). The correlation of BUA and speed of sound (SOS) between the two QUS devices was highly significant, with an r value of 0.92 for BUA and 0.91 for SOS. However, the correlation between DXA and ultrasound parameters ranged from 0.28 to 0.44. We found that ultrasound measurements at the heel were significant discriminators of hip fractures with odds ratios (OR) ranging from 2.7 to 3.2. Even after adjusting the logistic regressions for total, neck or trochanter femoral BMD, QUS variables were still significant independent discriminators of hip fracture. The areas under the ROC curves of each ultrasound parameter ranged from 0.75 to 0.78, and compared very well with femoral neck BMD (p〉0.05). In conclusion, our study indicated that the calcaneal QUS variables, as measured by the Sahara system can discriminate hip fracture patients equally as well as hip DXA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-2965
    Keywords: Key words:Hip fracture – Osteoporosis – Precision – Ultrasound attenuation – Ultrasound velocity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract: Quantitative ultrasound (QUS) is now accepted as a useful tool in the management of osteoporosis. There are a variety of QUS devices clinically available with a number of differences among them, including their coupling methods, parameter calculation algorithms and sites of measurement. This study evaluated the abilities of six calcaneal QUS devices to discriminate between normal and hip-fractured subjects compared with the established method of dual-energy X-ray absorptiometry (DXA). The short-term and mid-term precisions of these devices were also determined. Thirty-five women (mean age 74.5 ± 7.9 years) who had sustained a hip fracture within the past 3 years, and 35 age-matched controls (75.8 ± 5.6 years) were recruited. Ultrasound measurements were acquired using six ultrasound devices: three gel-coupled and three water-coupled devices. Bone mineral density was measured at the hip using DXA. Discrimination of fracture patients versus controls was assessed using logistic regression analysis (expressed as age- and BMI-adjusted odds ratios per standard deviation decrease with 95% confidence interval) and receiver operating characteristics (ROC) curve analysis. Measurement precision was standardized to the biological range (sCV). The sCV ranged from 3.14% to 5.5% for speed of sound (SOS) and from 2.45% to 6.01% for broadband ultrasound attenuation (BUA). The standardized medium-term precision ranged from 4.33% to 8.43% for SOS and from 2.77% to 6.91% for BUA. The pairwise Pearson correlation coefficients between different devices was highly significant (SOS, r= 0.79–0.93; BUA, r= 0.71–0.92). QUS variables correlated weakly, though significantly, with femoral BMD (SOS, r= 0.30–0.55; BUA, r= 0.35–0.61). The absolute BUA and SOS values varied among devices. The gel-coupled devices generally had a higher SOS than water-coupled devices. Bone mineral density (BMD) and BUA were weakly correlated with weight (r= 0.48–0.57 for BMD and r= 0.18–0.54 for BUA), whereas SOS was independent of weight. All the QUS devices gave similar, statistically significant hip fracture discrimination for both SOS and BUA measures. The odds ratios for SOS (2.1–2.8) and BUA (2.4–3.4) were comparable to those for femoral BMD (2.6–3.5), as were the area under the curve (SOS, 0.65–0.71; BUA, 0.62–0.71; BMD, 0.65–0.74) from ROC analysis. Within the limitation of the sample size all devices show similar diagnostic sensitivity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...