Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0935-6304
    Keywords: Large-volume on-column injection ; gas chromatography ; infrared spectrometry ; microcontaminants ; solid-phase extraction ; open-split interface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A large-volume on-column GC-cryotrapping-IR system was developed for injections of up to 100 μl of organic extracts. Considerable reduction of the solvent-and-water background and enhanced analyte detectability was achieved by using an open-split interface between the GC column and the IR detector and improving the leak-tightness of the system. The system was combined with solid-phase extraction to yield on-line SPE-GC-IR. With this set-up, sample volumes of only 20 ml sufficed to detect, and identify, microcontaminants in tap and surface water at the 0.1-1 μg/L level. Detection limits were on the order of 15 ng/L for tap water when using appropriate functional-group chromatograms. Or, in other words, SPE-GC-IR is a suitable technique for the screening of environmental water samples for functional groups, i.e. classes of compounds, of interest.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 7 (1995), S. 383-394 
    ISSN: 1040-7685
    Keywords: large-volume injection ; gas chromatography ; on-column injector ; environmental analysis ; organophosphorus pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Large-volume injection is an attractive means to improve detection limits when analyzing dilute sample extracts. There is now no need to achieve enrichment by means of solvent evaporation, which makes the total analytical procedure less reliable and less robust due to loss of volatile compounds. In this study on-column injection was applied for large-volume injection using an on-column injector in combination with a deactivated uncoated fused silica capillary (retention gap) and an early solvent vapor exit. Two strategies are described. The first one relies on the programmable speed of an infusion pump, which is adapted such that it lies just above the evaporation rate of the extraction solvent used. With the second procedure, which can be used for a commercially available autosampler, the evaporation speed is adjusted to the fixed speed of injection by varying the temperature during injection. During optimization the additional solvent evaporation time was determined. The optimum conditions for an injection volume of 100 μL of either n-hexane or ethyl acetate are reported. Large-volume injection was used for simplified and miniaturized solid-phase extraction procedures. The procedures were used to determine various organic micropollutants, such as organophosphorus pesticides and triazine herbicides, in tap and surface water extracts, using a flame photometric, and a mass spectrometric detector. For both methods good recovery for most of the analytes (70-87%), linear calibration curves (0.01-5 μg/L range), and relative standard deviations of less than 10% were obtained. Detection limits typically were in the range of 1-10 ng/L for GC-FPD and 10-150 ng/L for GC-MS. When working in the time-scheduled multiple ion detection mode detection limits in GC-MS were one order of magnitude lower. © 1995 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 450-456 
    ISSN: 0935-6304
    Keywords: Drying cartridge ; gas chromatography ; solid-phase extraction ; microcontaminants ; water samples ; on-line SPE-GC ; mass spectrometric detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---A drying cartridge was used and optimized for the in-line elimination of water from the desorption eluent in on-line solid phase extraction-gas chromatography (SPE-GC). The cartridge is essentially a small stainless-steel precolumn packed with a drying agent which can be regenerated by simultaneous heating and purging with a moisture-free gas. The drying cartridge was mounted on an additional valve instead of between the SPE-GC transfer valve and the on-column injector to enable regeneration of the cartridge during the GC run and, thus, to increase sample throughput. Three drying agents were tested, viz. sodium sulfate, silica, and molecular sieves. Although molecular sieves have the highest capacity, silica was preferred because of practical considerations. Large-volume injections were performed through the in-line drying cartridge using a mixture of 23 microcontaminants ranging widely in polarity and volatility. Four solvents were tested. With pentane and hexane, the more polar analytes were retained by the drying cartridge. Ethyl acetate and methyl acetate gave much better (and closely similar) recoveries for all analytes. Because water elimination on the silica cartridge proved to be less critical than with ethyl acetate, this solvent was finally selected. The entire SPE-drying cartridge-GC set-up was combined with mass spectrometric (MS) detection for the determination of a mixture of micropollutants in real-life water samples. With 10-ml tap water samples spiked at the 0.5 μg/l level, for the majority of the test compounds the analyte recoveries generally were 60-106%, and (full-scan) detection limits typically were 0.01-0.03 μg/l. Some very polar analytes such as, e.g. dimethoate, were (partially) sorbed onto the silica packing of the drying cartridge.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...