Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0584
    Keywords: Erythrocyte deformability ; Hemorrheology ; Clinical
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Hemorrheology, the science of the flow behavior of blood, has become increasingly important in clinical situations. The rheology of blood is dependent on its viscosity, which in turn is influenced by plasma viscosity, hematocrit, erythrocyte aggregation, and erythrocyte deformability. In recent years it has become apparent that the shape and elasticity of erythrocytes may be important in explaining the etiology of certain pathological situations. Thus, clinicians have become increasingly interested in hemorrheology in general and erythrocyte deformability in particular. In the course of time, many clinical studies have been performed, but no concise review has thus far been published. This article encompasses a review of the clinically based literature on this subject.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-5233
    Keywords: Diabetes mellitus ; Erythrocyte deformability ; Hyperosmolarity ; microalbuminuria ; Nephropathy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A lower erythrocyte deformability, which causes impairment of the microcirculation, is postulated to contribute to diabetic organ complications. Erythrocyte deformability was measured in four groups of type 1 (insulin-dependent) diabetic subjects and 30 controls by filtration and ektacytometry. Twenty-five patients without overt nephropathy and 12 with leg ulceration were studied. No decreased erythrocyte deformability was found in any of the diabetic groups with either technique, and neither did the total group of 71 diabetic subjects have a lower erythrocyte deformability when compared with the controls. In order to imitate local conditions in the kidney, erythrocyte deformability was also measured in hyperosmolar solutions. Again no differences were found between the diabetic groups separately or as a whole and the controls. Furthermore no correlation was found between erythrocyte deformability and the plasma glucose or glycosylated haemoglobin level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 7 (1982), S. 528-529 
    ISSN: 1619-7089
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1573-9686
    Keywords: Conductivity ; Erythrocytes ; Ultrasound ; Shear stress
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract A modified conductance method to determine the cross-sectional areas (CSAs) of arteries in piglets was evaluated in vivo. The method utilized a conductance catheter having four electrodes. Between the outer electrodes an alternating current was applied and between the inner electrodes the induced voltage difference was measured and converted into a conductance. CSA was determined from measured conductance minus parallel conductance, which is the conductance of the tissues surrounding the vessel times the length between the measuring electrodes of the conductance catheter divided by the conductivity of blood. The parallel conductance was determined by injecting hypertonic saline to change blood conductivity. The conductivity of blood was calculated from temperature and hematocrit and corrected for maximal deformation and changes in orientation of the erythrocytes under shear stress conditions. The equations to calculate the conductivity of blood were obtained from in vitro experiments. In vivo average aortic CSAs, determined with the conductance method CSA (G) in five piglets, were compared to those determined with the intravascular ultrasound method CSA(IVUS). The regression equation between both values was CSA (G) =−0.09+1.00·CSA(IVUS) r=0.97, n=53. The mean difference between the values was −0.29% · 5.57% (2 standard deviations). We conclude that the modified conductance method is a reliable technique to estimate the average cross-sectional areas of the aorta in piglets. © 1999 Biomedical Engineering Society. PAC99: 8780-y, 8437+q, 8719Nn
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...