Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 96 (1992), S. 10316-10322 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-2932
    Keywords: acid rain ; acid deposition ; acid fraction ; precipitation pH and conductivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract A microprocessor-based acid rain monitor was used to make real-time measurements of conductivity and pH of rainwater within individual storms. The automated measurements were compared with laboratory analyses of a subset of the samples taken. The laboratory measurements tended to overestimate the pH because of temperature induced changes in dissociation and Henry's Law constants affecting ionic compounds in the rainwater. The measurement artefact due to these effects may result in average hydrogen ion concentrations being underestimated by approximately 10 to 15% at UK sites. The greatest systematic discrepancies would be anticipated at highly polluted sites and during low temperature acidic episodes. The concept of a rainwater acid fraction was investigated and found to be useful for quality control and interpretative purposes. The field measurement of conductivity of low ionic strength samples was slightly lower than the corresponding laboratory measurement, possibly caused by limited resolution of the conductivity probe or dissolution of fine particulate material.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-2932
    Keywords: acid rain ; acid deposition ; acid fraction ; precipitation pH and conductivity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract A microprocessor-based acid rain monitor was used to make real-time measurements of conductivity and pH of rainwater within individual storms. The automated measurements were compared with laboratory analyses of a subset of the samples taken. The laboratory measurements tended to overestimate the pH because of temperature induced changes in dissociation and Henry's Law constants affecting ionic compounds in the rainwater. The measurement artefact due to these effects may result in average hydrogen ion concentrations being underestimated by approximately 10 to 15% at UK sites. The greatest systematic discrepancies would be anticipated at highly polluted sites and during low temperature acidic episodes. The concept of a rainwater acid fraction was investigated and found to be useful fro quality control and interpretative purposes. The field measurement of conductivity of low ionic strength samples was slightly lower than the corresponding laboratory measurement, possibly caused by limited resolutio nof the conductivity probe or dissolution of fine particulate material.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Environmental monitoring and assessment 62 (2000), S. 39-54 
    ISSN: 1573-2959
    Keywords: air monitoring ; chemical model ; nitrogen oxides ; passive sampler
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Measurement of nitrogen dioxide using passivediffusion tube over 22 months in Cambridge, U.K. areanalysed as a function of sampler exposure time, andcompared with NO2 concentrations obtained from aco-located chemiluminescence analyser. The averageratios of passive sampler to analyser NO2 at acity centre site (mean NO2 concentration 22 ppb)are 1.27 (n = 22), 1.16 (n = 34) and 1.11 (n = 7) forexposures of 1, 2 and 4-weeks, respectively. Modellingthe generation of extra NO2 arising from chemicalreaction between co-diffusing NO and O3 in thetube gave a ratio (modelled/measured) of 1.31 for1-week exposures. Such overestimation is greatest whenNO2 constitutes, on average, about half of totalNOx (= NO + NO2) at the monitoring locality.Although 4-week exposures gave concentrations whichwere not significantly different from analyserNO2, there was no correlation between thedatasets. At both the city-centre site and anothersemi-rural site (mean NO2 concentration 11 ppb)the average of the aggregate of four consecutive1-week sampler exposures or of two consecutive 2-weeksampler exposures was systematically greater than fora single 4-week exposure.The results indicate two independent and opposingsystematic biases in measurement of NO2 bypassive diffusion sampler: an exposure-timeindependent chemical overestimation with magnitudedetermined by local relative concentrations of NO andO3 to NO2, and an exposure-time dependentreduction in sampling efficiency. The impact of theseand other potential sources of systematic bias on theapplication of passive diffusion tubes for assessingambient concentrations of NO2 in short (1-week)or long (4-week) exposures are discussed in detail.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...