Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 116 (1994), S. 9407-9408 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 24 (2001), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: GRIMM, W., et al.: Reversal of Tachycardia Induced Cardiomyopathy Following Ablation of Repetitive Monomorphic Right Ventricular Outflow Tract Tachycardia. Radiofrequency catheter ablation was performed in four adults with myocardial dysfunction related to repetitive monomorphic ventricular tachycardia (RMVT) originating in the right ventricular outflow tract. Serial echocardiographic assessment of left ventricular function before and after radiofrequency catheter ablation of RMVT showed complete reversal of left ventricular dysfunction without arrhythmia recurrence during 31 ± 28 months follow-up.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The Marburg Cardiomyopathy Study (MACAS) is a prospective, observational study designed to determine the value of the following potential noninvasive arrhythmia risk predictors in at least 200 patients with idiopathic dilated Cardiomyopathy (IDC) over a 5-year follow-up period: NYHA-class, left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter, left bundle branch block and atrial fibrillation on ECG, QT/JT dispersion on 12-lead ECG, signal-averaged ECG, ventricular arrhythmias and heart rate variability (HRV) on 24-hour Hotter ECG, baroreflex sensitivity, and microvolt T wave alternans during exercise. This article describes the findings among the first 159 patients with IDCs enrolled in MACAS until May 1998 (40 women, 119 men;age:49 ± 12 years; LVEF: 32 ± 10%). Twenty-nine patients (18%) had atrial fibrillation and 130 patients (82%) were in sinus rhythm. Patients with sinus rhythm were further stratified according to LVEF 〈 30% (n = 54) versus LVEF ≥ 50% (n = 76). Compared to patients with LVEF ≥ 30%, patients with LVEF 〈 30% more often had left bundle branch block (43% vs 25%, P 〈 0.05), nonsustained VT (44% vs 22%, P 〈 0.05), decreased HRV (SDNN: 95 ± 39 vs 128 ± 42 ms, P 〈 0.01), decreased baroreflex sensitivity (5.6 ± 4 vs 8.3 ± 6 ms/mmHg, P 〈 0.01), and T wave alternans (59% vs 37%, P 〈 0.05). The prognostic significance of these findings will be determined by multivariate Cox analysis at the end of a 5-year follow-up. Primary endpoints in MACAS are overall mortality and arrhythmic events (i.e., sustained VT or VF, or sudden cardiac death).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 22 (1999), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: To determine the incidence of complications of third-generation implantable cardioverter defibrillator (ICD) therapy, 144 patients were prospectively studied who underwent first implant of third-generation devices (i.e., ICD systems with biphasic shocks, ECC storage capability, and nonthoracotomy lead systems). During 21 ± 15 months of follow-up, 41 (28%) patients had one or more complications. No patient died perioperatively (30 days) and no ICD infection was observed during follow-up. Complications included bleeding or pocket hematoma (hemoglobin drop 〉 2 g/dL) in 5 (3%) patients, prolonged reversible ischemic neurological deficit in 1 (1%) patient, postoperative deep venous thrombosis of leg in 1 (1%) patient, pneumothorax in 2 (1%) patients, difficulty to defibrillate ventricular fibrillation intraoperatively in 2 (1%) patients, generator malfunction in 1 (1%) patient, arthritis of the shoulder in 3 (2%) patients, and allergic reaction to prophylactic antibiotics in 2 (1%) patients. A total of seven lead related complications were observed in six (4%) patients including endocardial lead migration in four (3%) patients. Twenty-three (16%) patients received inappropriate shocks for supraventricular tachyarrhythmias (n = 13), non-sustained ventricular tachycardia (VT) (n = 7), or myopotential oversensing (n = 3). We conclude that serious complications such as perioperative death or ICD infection are rare in patients with third-generation ICDs. Lead-related problems and inappropriate shocks during follow-up are the most frequent complications of third-generation ICD therapy. Recognition of these complications should promote advances in ICD technology and management strategies to avoid their recurrence.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 21 (1998), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The relation between heart rate variability (HRV) and outcome of head-up tilt testing (HUT) in patients with neurally mediated syncope (NMS) was studied in 30 patients with presumed NMS (33 ± 13 years) and in 11 age-matched controls. After 15 minutes of baseline supine observation, patients were tilted to 60± for 45 minutes or until syncope occurred. HRV parameters included RR intervals, standard deviation of normal-to-normal RR intervals (SDNN), and root mean square successive differences (RMSSD). HRV analysis was performed during 5-minute intervals in the supine position immediately after onset of HUT and before syncope or after 30–35 minutes of tilt in patients without syncope. Syncope occurred after a mean tilt duration of 32 minutes in 14 (47%) of 30 patients with presumed NMS, whereas all controls had an uneventful HUT. In the supine position, RR intervals and RMSSD were comparable among HUT-positive patients, HUT-negative patients, and controls (RR intervals: 799 ± 92, 854 ± 137, and 818 ± 128 ms, P = NS; RMSSD: 43 ± 40, 36 ± 34, and 53 ± 42 ms, P = NS). Baseline SDNN was also comparable in HUT-positive patients versus HUT-negative patients with presumed NMS (50 ± 26 vs 52 ± 20 ms, P = NS). Within 5 minutes preceding syncope or after 30–35 minutes of tilt, RR intervals and RMSSD were shorter in HUT-positive patients compared to HUT-negative patients, or to controls (RR intervals: 606 ± 86 vs 710 ± 117 and 739 ± 123 ms, P 〈 0.05; RMSSD: 12 ± 5 vs 23 ± 19 and 40 ± 32 ms, P 〈 0.05). Thus, HRV analysis in the baseline supine position was not a predictor of HUT outcome in patients with suspected NMS. Syncope during HUT seemed to be preceded by increased sympathetic activity manifested by an increase in heart rate and by a decreased parasympathetic tone manifested by a decrease in RMSSD measured for 5 minutes before the event, in comparison with HUT-negative patients and with controls.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Unnecessary shocks by ICDs for rhythms other than sustained VT or VF have been described as the most frequent adverse event in ICD patients. To avoid unnecessary shocks for self-terminating arrhythmias, the third-generation Jewel PCD defibrillators 7202, 7219, and 7220 Plus use a specially designed VF confirmation algorithm after charge end. The purpose of this study was to determine the ability of this VF confirmation algorithm to recognize nonsustained VT, and to analyze the reasons for failure of the PCD device to abort shock therapy for nonsustained VT despite use of this VF confirmation algorithm. Analysis of stored electrograms of electrical events triggering high voltage capacitor charging in the programmed VF zone of the device showed 36 spontaneous episodes of nonsustained VT (227 ± 21 beats/mm) during 18 ± 7 months follow-up in 15 patients who had a Jewel PCD implanted at our hospital. Intracardiac electrogram recordings and simultaneously retrieved marker channels demonstrated that the ICD shock was appropriately aborted according to the VF confirmation algorithm in 24 (67%) of 36 episodes of nonsustained VT. Twelve episodes (33%) of nonsustained VT, however, were followed by a spontaneous ICD shock in 6 (40%) of the 15 study patients. The only reason for all 12 shocks for nonsustained VT was the inability of the device to recognize the absence of VT after charge end due to shortcomings of the VF confirmation algorithm: 11 of the 12 shocks for nonsustained VT were triggered by the occurrence of paced beats during the VF confirmation period and 1 shock for nonsustained VT was triggered by the occurrence of 2 premature beats after charge end. Thus, better VF confirmation algorithms need to be incorporated in future PCD devices to avoid unnecessary shocks for nonsustained VT.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Early or localized forms of arrhythmogenic right ventricular dysplasia (ARVD) have been proposed as the arrhythmogenic substrate of repetitive monomorphic ventricular tachycardia (RMVT) originating in the right ventricular outflow tract in patients without any underlying cardiac abnormality on clinical examination and echocardiography. To further examine this hypothesis, magnetic resonance imaging (MRI) and signal-averaged electrocardiography (SAECG) were performed on 23 patients with RMVT and normal 12-lead standard ECG of conducted sinus beats. MRI was performed using ECG-gated turbo spin-echo images of the heart in order to detect signs of early or localized forms of ARVD, such as localized wall thickness reductions, signal intensity increase indicating adipose tissue infiltrates, and regional bulgings or aneurysms. MRI was normal in 22 (96%) of 23 study patients. In the remaining patient (4%), MRI demonstrated signal intensity increase in the intraventricular septum but not in the right ventricular outflow tract. Time-domain analysis of the SAECG was normal in 21 (91 %) of 23 patients and revealed ventricular late potentials in 2 study patients (9%). Frequency-domain analysis of the SAECG was normal in 22 (96%) of 23 patients and revealed ventricular late potentials in one study patient (4 %). We conclude that normal MRI findings of the heart and absence of ventricular late potentials in the SAECC in most patients with RMVT and otherwise normal ECG do not support the hypothesis that early or localized forms of ARVD create the arrhythmogenic substrate in the majority of these patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The influence of the clinical presentation on the long-term outcome in 213 consecutive patients with ICDs, ECG storage capability, and nonthoracotomy leads, was analyzed. Sixty-six patients presented with cardiac arrest (CA), 81 patients with hemodynamically stable VT, and 66 patients with syncope (SY). Patient characteristics were: mean age CA 62, VT 61, SY 61 years; mean ejection fraction CA 31%, VT 29%, SY 30%; coronary artery disease CA 71%, VT 71%, SY 64% (all P 〉 0.05 Fisher's exact test); female gender CA 40%, VT 14%, SY 19% (CA vs VT and SY, P 〈 0.005); inducibility by programmed stimulation CA 50%, VT 84%, SY61 % (VT vs CA and SY, P 〈 0.001, CA vs SY, P 〉 0.05). During a mean follow-up of 14.5 months, 29 patients died; CA 12%, VT 14%, SY 9% (P 〉 0.05). Comparing Kaplan-Meier curves, no difference in the time course of overall mortality was found (log-rank P 〉 0.05). In the CA, VT, and SY groups, 543, 1,630, and 189 ICD therapies (including antitachycardia pacing, low energy cardioversion, and defibrillation) were observed, respectively. Actuarial analysis showed a shorter interval between implantation and first ICD therapy for VT versus CA and SY (log-rank P 〈 0.005). Patients presenting with VT experienced earlier and more frequent ICD therapies than patients with CA or SY independent of age, ejection fraction, and heart disease. No difference in overall mortality and time course of fatal events was observed among the three groups.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Dental traumatology 21 (2005), S. 0 
    ISSN: 1600-0595
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract –  The hazards of damage to teeth and their periodontal attachment during tracheal intubation are well known. Dental trauma represents the commonest single reason for complaints against anesthesiologists. In order to predict the possible risk of perianesthetic iatrogenic tooth luxation we evaluated the use of a measuring method (Periotest® technique), being well established for the diagnosis of periodontal disease. In 120 patients undergoing elective surgery, we compared the amount of tooth mobility before and after general anesthesia to different scores assessing the difficulty of tracheal intubation. Furthermore, the level of work experience of the intubating anesthetist was compared with the degree of postoperative tooth mobility. Changes of periodontal attachment could not be detected by the Periotest® technique. The Periotest® technique does not seem to have the ability to detect early periodontal changes associated with endotracheal intubation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 10 (1999), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Torsades de Pointes after PJRT Ablation. Introduction: Catheter ablation with radiofrequency energy is a curative therapy in patients with permanent junctional reciprocating tachycardia (PJRT). Methods and Results: For the first time, we report a case of transient QT prolongation with torsades de pointes tachycardia 18 hours after successful radiofrequency energy ablation of PJRT in a 25-year-old woman with tachycardia-induced cardiomyopathy. Of note, the torsades de pointes occurred in the absence of bradycardia, electrolyte disturbances, or QT-prolonging drugs. This patient initially was thought to have a hereditary long QT syndrome that was unmasked by PJRT ablation. Therefore, the patient received an implantable defibrillator in addition to beta-blocker therapy, which was discontinued 6 months later. Surprisingly, the QT interval completely normalized within 1 week after PJRT ablation, and the patient remained free of arrhythmias during a follow-up period of 4.5 years. Conclusion: Patients with incessant tachyarrhythmias should undergo ECG monitoring for at least 24 hours following successful radiofrequency catheter ablation because transient QT prolongation with torsades de pointes may occur even in the absence of bradycardia, QT-prolonging drugs, or electrolyte disturbances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...