Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0021-9614
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    The @Journal of Chemical Thermodynamics 10 (1978), S. 225-229 
    ISSN: 0021-9614
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    The @Journal of Chemical Thermodynamics 10 (1978), S. 213-223 
    ISSN: 0021-9614
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Acta Psychologica 75 (1990), S. 213-223 
    ISSN: 0001-6918
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Psychology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Chromatography B: Biomedical Sciences and Applications 230 (1982), S. 345-352 
    ISSN: 0378-4347
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Chromatography B: Biomedical Sciences and Applications 493 (1989), S. 305-312 
    ISSN: 0378-4347
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 13 (1999), S. 123-126 
    ISSN: 1432-2218
    Keywords: Key words: Video-assisted thoracoscopic surgery — Upper thoracic spine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: The standard open technique for exposure of the upper thoracic spine, T1–T4, usually requires a difficult thoracotomy. From November 1, 1995 to June 30, 1997, eight patients underwent video-assisted thoracoscopic spinal surgery in our institute to treat their upper thoracic spinal lesions endoscopically. Methods: A new approach, the so-called ``extended manipulating channel method,'' was used in this series that allows the combined use of video-assisted thoracoscopy and conventional spinal instruments to enter the chest cavity freely for the procedures. Patients' ages ranged from 44 to 89 years (average, 60 years). Definitive diagnoses included two pyogenic spondylitis and six spinal metastases. Five patients presented initially with myelopathy. Results: There were no deaths or neurologic injuries associated with this technique. The mean surgical time was 3.1 h. The mean duration of chest tube retention was 3.3 days. The mean total blood loss was 1,038 ml, and two patients had a blood loss of more than 2,000 ml owing to bleeding from epidural veins or raw osseous surfaces. Complications included one superficial wound infection and one subcutaneous emphysema that resolved spontaneously. In this series, there was no need of conversion to open thoracotomy for the patients. Conclusions: The thoracoscopy-assisted spinal technique using the extended manipulating channels, usually 2.5–3.5 cm, allows variable instrument angulations for manipulation. The mean surgical time (3.1 h) was considered no longer than for an open technique for the equivalent anterior procedure. Such an approach can achieve less procedure-related trauma and has proved to be a good alternative to other treatment modalities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 11 (1997), S. 1189-1193 
    ISSN: 1432-2218
    Keywords: Key words: Video-assisted thoracoscopic surgery — Thoracolumbar junction — Spinal lesions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: The endoscopic treatment of spinal lesions in the thoracolumbar junction (T11–L2) poses a great challenge to the surgeon. From November 1, 1995 to December 31, 1996, we successfully used a combination of video-assisted thoracoscopy and conventional spinal instruments to treat 38 patients with anterior spinal lesions. Twelve of them had lesions in the thoracolumbar junction. Methods: The so-called extended manipulating channel method was used to perform vertebral biopsy, discectomy, decompressive corpectomy, interbody fusions, and/or internal fixations in these patients. The size of the thoracoscopic portals was greater than usual in order to allow conventional spinal instruments and a thoracoscope to enter the chest cavity freely and be manipulated by techniques similar to those used in standard open surgical procedures. In this series, the procedures were performed by using either a three-portal approach (2.5–3.5 cm) or a modified two-portal technique involving a 5–6 cm larger incision and a small one for introducing the scope. Results: None of the operations resulted in injury to the great vessels, internal organs, or spinal cord. The total time for the operation ranged from 1.5 to 4.5 h (average, 3); and the total blood loss ranged from 50 to 3000 cc (average, 1050). One patient was converted to an open procedure due to severe pleural adhesion. Complications included two instances of transient intercostal neuralgia, one superfical wound infection, and one residual pneumothorax. Conclusions: The video-assisted technique with the extended manipulating channel method presented in this report simplifies thoracoscopic spinal surgery in the thoracolumbar junction and makes it easier. It avoids division of the diaphragm, removal of the rib, and wide spread of the intercostal space, and it allows greater control of intraoperative vessel bleeding. Using this technique, the number of portals required during the procedure can be reduced. In addition, the technique reduces the endoscopic materials required, thus lowering overall cost. It is an effective and promising approach.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 61 (1995), S. 511-514 
    ISSN: 1432-0649
    Keywords: 42.30 ; 42.40 ; 42.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We consider the possibility of restoration and/or enhancement of decaying holograms in photorefractive media by using a simple optical readout in conjunction with a phase conjugator. The results indicate that extremely weak holograms can be enhanced provided that the two-beam coupling is sufficiently strong. Steady-state photorefractive holograms can be maintained continuously without decay by using a self-enhanced readout scheme. The results also provide an explanation for the formation of mutually pumped phase conjugation in terms of the amplification of an initial noise grating. The results are presented and discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 117 (1998), S. 92-95 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Between November 1, 1995, and January 31, 1996, four separate thoracoscopic spinal fixation surgeries were performed via extended manipulating channels using the so-called three-portal technique. The diagnoses included three spinal metastases and one T11 burst fracture. All patients had myelopathy at presentation. Using the three-portal technique, the conventional spinal instruments and fixation devices could be passed freely through the extended manipulating channels (usually 3–4 cm) into the chest cavity and manipulated by techniques similar to those used in standard open procedures. A reduction-fixation spinal plate with variable screw and plate anchoring angles was successfully inserted in the procedures. The total length of the operation ranged from 3.5 to 5 h (average 4.3 h), and the total blood loss was 1000–2500 ml (average 1500 ml). There were no intraoperative deaths, and no patient showed neurological deterioration following the procedures. On the basis of these results, we believe that the combination of video-assisted thoracoscopy and conventional spinal instruments presented in this report would be an ideal method for performing these procedures. Throughout the operation, only one trocar was employed for introducing the thoracoscope. The thoracoports were used temporarily during tumor tissue retrievals. This technique makes thoracoscopy-assisted spinal fixation simple and easy. It allows greater control of intraoperative vessel bleeding and reduces the number of portals required during the procedure (on average to 3). In addition, the technique reduced the amount of endoscopic materials required for the procedure, thus reducing the cost of treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...