Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 7 (2000), S. 189-195 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The wavelength of the 14.4 keV Mössbauer photon has been determined by using undulator radiation and diffraction of FZ silicon crystals. For the wavelength determination a goniometer equipped with a laser rotary encoder and a sine-bar angle optical interferometer was developed; a temperature-monitoring system and X-ray optics related to the experiment were also developed. The mean wavelength was 0.08602557 nm with an uncertainty of 0.6 p.p.m., derived from 16 measurements of three pieces of FZ Si(840) crystals.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 6 (1992), S. 222-223 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A new method for the quantification of famotidine consists of a simple extraction procedure and paired-ion high performance liquid chromatography with ultraviolet detection. The method has good accuracy and precision and should be suitable for the routine measurement of plasma and urine samples for clinical studies.
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 29 (1987), S. 982-993 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A simple and convenient method for measuring KLa in large-scale fermentors was proposed. This method was based on the measurement of the dissolved oxygen concentration under steady state conditions established by an equivalency of the sulfite ion feed and chemical oxidation rates. This method had the following advantages: It was a steady state method, and so it was not necessary to consider the response lag of a dissolved oxygen probe and the response lag due to gas phase mixing in fermentors. The oxygen content of the effluent gas in this measuring system was nearly the same as that of the sparged air. Therefore, it was possible to use the oxygen partial pressure of the sparged air for the calculation of the driving force of oxygen transfer. The detailed information on the kinetics of sulfite oxidation was not necessary, because the dissolved oxygen concentration in steady state was not influenced by sulfite oxidation rates. The KLa measurement was finished in as short a period as 150 s, even in a fermentor with a volume of 10 m3. Since the amount of Na2SO4 accumulation in the test fermentors was very small because of the quick measurement, the KLa values obtained by this method were applicable to the electrolyte-free system. Furthermore, we could discharge the used liquid from the fermentors into a drain without any pretreatment due to the low salt concentration.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...