Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 60 (1938), S. 136-137 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 33 (2000), S. 243-251 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A charge-coupled device (CCD)-based detector designed for macromolecular crystallography is described. The detector has an area of 200 × 200 mm, a readout time of 1.6 s, and total noise equivalent to approximately three 12 keV X-ray photons per pixel. The detector is constructed from a 2 × 2 array of four identical units, each unit consisting of a 4.1:1 demagnifying fiber-optic taper bonded to a 1 k × 1 k, 24 µm pixel, CCD sensor. Each CCD is read out in parallel though four channels and digitized to 16 bits. A Gd2O2S phosphor X-ray-to-light converter bonded to an aluminized-plastic film is held in contact with the input surfaces of the fiber-optic tapers with an air pillow. The full width at half-maximum (FWHM) of the point response function is 120 µm, the response is linear to better than 1% over the entire range of intensity from background to nearly full well, the gain is 3.4 e per 8 keV incident X-ray photon, the noise is 12.6 e per pixel for a 10 s integration time, the modulation transfer function (MTF) is 0.35 at 5 line pairs (lp) mm−1 (the Nyquest frequency), and the measured detective quantum efficiency (DQE) is 0.74 for relatively strong Bragg peaks. Data collected from crystallographic studies with synchrotron radiation are presented. In an anomalous difference Patterson map for a data set collected in 40 min on a monoclinic myoglobin crystal, the magnitude of the Fe–Fe peaks is 18 times the standard uncertainty of the map.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...