Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of interventional cardiology 14 (2001), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Although optimized antiplatelet medication has improved the clinical outcome after coronary stenting, vessel occlusion and restenosis still remain a relevant clinical problem. Platelets play a key role in this process. Therefore, the authors compared the platelet adhesion on different stent surface modifications (electropolished without coating or coated with carbon, carbon and additional heparin, silicon carbide, or heparin alone) to investigate their role in reducing platelet adhesion. All stem and additional stainless steel plates were incubated in heparinized whole blood with radiolabeled platelets. Afrer washing the stents and plates four times, radioactivity caused by the adhesion of radiolabeled platelets was measured. The adhesion of radiolabeled platelets, compared to uncoated, electropolished stents, was reduced through silicon carbide coating to 58.6%, by carbon coating with additional heparin to 32.9%, and heparin coating alone to 7.7%. Stent coating with heparin is the most effective among the examined coatings in reducing platelet adhesion in vitro.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 238 (2000), S. 861-867 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Background: The use of a viscoelastic substance facilitates cataract surgery. Healon 5 is a new viscoelastic product with special rheological properties. We evaluated the postoperative effect of Viscoat and Healon5 on intraocular pressure (IOP), central corneal thickness (CCT), endothelial cell counts and laser flare. Methods: Forty-eight eyes of 48 patients undergoing routine phacoemulsification followed by foldable IOL implantation were enrolled. Either Healon5 or Viscoat was used according to a block- randomization scheme. The aspiration technique was standardized. IOP, CCT, endothelial cell counts and laser flare were compared pre- and postoperatively. Statistical analysis was performed using the two-sample Wilcoxon test. Data description was based on median and quartiles, while graphic description was performed by non-parametric box plots. Results: Viscoat demonstrated a statistically significant higher IOP than Healon5 at 4 and 8 h postoperatively (P〈0.01 and 〈0.05, respectively). Further, the laser flare values were statistically significantly higher for the Viscoat than for the Healon5 group 8 h postoperatively (P〈0.05). Endothelial cell loss did not differ significantly between the two groups (relative change in endothelial cell density after 3 months: –4.3% for the Healon5 group and –6.2% for Viscoat group). Conclusion: There was neither a statistically nor a clinically significant difference in endothelial cell loss after the use of Healon5 or Viscoat in routine cataract surgery. However, the IOP in the early postoperative period was higher in the Viscoat group than in the Healon5 group.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...