Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of agricultural and food chemistry 30 (1982), S. 435-439 
    ISSN: 1520-5118
    Source: ACS Legacy Archives
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method for the determination of low molecular weight aliphatic primary amines in urine is described. These amines were converted into their benzenesulphonyl derivatives by a modified Hinsberg procedure, and measured by gas chromatography with flame photometric detection (FPD-GC) using a DB-1 capillary column. The derivatives were very stable and provided excellent FPD responses. By FPD-GC, linear calibration curves were obtained in the range 10-200 ng of methylamine, ethylamine, n-propylamine, isobutylamine and n-butylamine using tert-butylamine as an internal standard, and the detection limits of these amines were ca. 6-25 pg as the injection amount. Benzenesulphonamide derived from ammonia was converted into its N-dimethylaminomethylene derivative which has a longer retention time, and separated from benzenesulphonyl derivatives of low molecular weight primary amines on the chromatogram. The recoveries of aliphatic primary amines added to urine samples were 91-107% and the relative standard deviations were 0.2-4.5%. Analytical results of aliphatic primary amine contents in urine samples of normal subjects are presented.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 9 (1995), S. 85-89 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method for the determination of glutathione (GSH) and related aminothiols such as cysteine (Cys), cysteinylglycine (CysGly) and γ-glutamylcysteine (γ-GluCys) by gas chromatography (GC) has been developed. GSH and related aminothiols were converted into their N, S-isopropoxycarbonyl methyl ester derivatives and measured by GC with flame photometric detection using a short capillary column (5 m × 0.53 mm i.d.) of cross-linked DB-1. The calibration curves were linear in the range 1-25 nmol for GSH and in the range 0.2-5 nmol for other aminothiols, and the detection limits of GSH, Cys, CysGly and γ-GluCys were approximately 5, 0.2, 0.3 and 0.5 pmol per injection respectively. This method was successfully applied to blood samples without prior clean-up, and GSH and related aminothiols in these samples could be analysed without any influence from coexisting substances. Overall recoveries of GSH and other aminothiols added to blood samples were 88-107%. The analytical results of free and total blood GSH and related aminothiols in normal subjects are presented.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method has been developed for the determination of secondary amines by gas chromatography (GC). After removal of primary amines by the reaction with o-phthaldialdehyde, secondary amines were converted into their N-diethylthiophosphoryl derivatives and then measured by GC with flame photometric detection using a DB-1701 capillary column. The derivatives were sufficiently volatile and stable to give single symmetrical peaks. The detection limits of secondary amines were ca. 0.05-0.2 pmol per injection. N-Methylcyclohexylamine was used as an internal standard. The calibration curves for secondary amines in the range 1-20 nmol were linear and sufficiently reproducible for quantitative determination. This method was successfully applied to small urine samples without prior clean-up. Overall recoveries of secondary amines added to urine samples were 91-105%. By using this method, secondary amines in urine samples could be analysed without any influence from primary amines and other coexisting substances. The analytical results of secondary amine content in urine samples of normal subjects are presented.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method for the determination of free and total proline (Pro) and 4-hydroxyproline (Hyp) by gas chromatography (GC) was developed. For free Pro and Hyp analysis, plasma and tissue homogenate were extracted with methanol. For total Pro and Hyp analysis, these samples were hydrolysed in 6 M HCI. After removal of primary amino compounds by the reaction with o-phthaldialdehyde, Pro and Hyp in methanol extract and acid hydrolysate were converted into their N-dimethylthiophosphoryl methyl ester derivatives and then determined by GC with flame photometric detection using a DB-5 capillary column. This method was successfully applied to small samples without prior clean-up, and Pro and Hyp in these samples could be analysed without any influence from coexisting substances. Overall recoveries of Pro and Hyp added to plasma and tissue samples were 92-106%. The analytical results of free and total Pro and Hyp in human plasma and mouse tissue samples are presented.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 7 (1993), S. 184-188 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method has been developed for the analysis of free and bound forms of O-phosphoamino acids, such as O-phosphoserine, O-phosphothreonine and O-phosphotyrosine, in urine samples by gas chromatography (GC). For free O-phosphoamino acid analysis, the urine sample was extracted with trichloroacetic acid and run through an ion exchange column. For total (free plus bound) O-phosphoamino acid analysis, the urine sample was hydrolysed in acid and base in order to release the O-phosphoamino acid from peptides or proteins. O-Phosphoamino acids in these prepared samples were converted into their N-isobutoxycarbonyl trimethyl ester derivatives and then measured by GC with flame photometric detection (FPD-GC). The calibration curve was linear in the range of 10-500 ng for each O-phosphoamino acid, and the detection limits were 30-80 pg as injection amounts. O-Phosphoamino acids in the urine samples could be selectively determined by the FPD-GC method without any influence from coexisting substances. The recoveries of O-phosphoamino acids added to urines and urine hydrolysates were 90-98% and relative standard deviations were 1.5-8.0%. By using this method, we investigated an age dependence of O-phosphoamino acid excretion in normal subjects.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 8 (1994), S. 119-124 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A selective and sensitive method has been developed for the determination of sulphur amino acids by gas chromatography (GC). Sulphur amino acids were converted into their N(S)-isopropoxycarbonyl methyl ester derivatives and measured by GC with flame photometric detection using a DB-17 capillary column. The derivatives were sufficiently volatile and stable to give single symmetrical peaks. The detection limits of sulphur amino acids were ca. 0.5-1 pmol per injection, and the calibration curves were linear in the range 0.5-1 nmol for each sulphur amino acid. This method was successfully applied to small urine samples without prior cleanup, and sulphur amino acids in these samples could be analysed without any influence from coexisting substances. Overall recoveries of sulphur amino acids added to urine samples were 85-113%. The analytical results of free sulphur amino acid contents in urine samples of normal subjects are presented.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 9 (1995), S. 243-245 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A rapid, selective and sensitive method for the determination of pamidronate in human plasma and urine samples by gas chromatography (GC) has been developed. After deproteinization of the sample with trichloroacetic acid, pamidronate was converted into its N-isobutoxycarbonyl methyl ester derivative and measured by GC with flame photometric detection (FPD), using a HP-1 capillary column. The derivative preparation and GC analysis were accomplished within 30 min. The derivative was sufficiently volatile and stable, giving a single and symmetrical peak, and provided an excellent FPD response. The detection limit of pamidronate, at a signal-to-noise ratio of 3, was ca. 100 pg injected, and the calibration curve for this compound in the range 20-1000 ng was linear and sufficiently reproducible for quantitative determination. This method could be successfully applied to plasma and urine samples without a preliminary clean-up except for deproteinization with trichloroacetic acid, and pamidronate could be measured without any influence from coexisting substances. Overall recoveries of pamidronate added to plasma and urine samples were 93-97%. The coefficients of variation for intra-assay and inter-assay of pamidronate in these samples were 1.0-7.9% (n = 3) and 4.1-8.3% (n = 6), respectively.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 9 (1995), S. 205-210 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A simple and rapid method for the determination of the 22 protein amino acids by capillary gas chromatography is described. The amino acids were converted into their N(O,S)-isobutoxycarbonyl (isoBOC) methyl ester derivatives and measured by GC with flame ionization detection using a DB-17 capillary column. Arginine was converted into ornithine by arginase treatment prior to the isoBOC reaction. The N(O,S)-isobutoxycarbonylation of amino acids with isobutyl chloroformate was completed within 15 s by sonication in aqueous alkaline media. All of the derivatives were quantitatively resolved as single symmetrical peaks within 9 min by GC on a single column. The detection limits of amino acids were 0.2-4.0 ng per injection, and the calibration curves were linear in the range 0.2-50 μg for each amino acid. This method was successfully applied to protein hydrolysate samples. The analytical results of amino acid compositions of several proteins are presented.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...