Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0090-6980
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 21 (1995), S. 76-78 
    ISSN: 1432-1238
    Keywords: Brain death ; Brain stem death ; VEP ; BAEP ; Cortical activity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A 46-year-old man was diagnosed clinically brain dead after sustaining head trauma. The patient was in deep coma, brain nerves were unresponsive and spontaneous breathing was absent. However, EEG showed well preserved activity, but no reactivity to external stimuli. EEG activity disappeared within 40 h. BAEP were highly abnormal, flash-VEP as recorded 3 h after the diagnosis of brain stem death was of high amplitude but of simplified form. The neurophysiological findings revealed that the main reason for deep coma was brain stem damage while cortical activity was still present. This condition raises ethical questions when brain death is diagnosed clinically prior to removal of organs for transplantation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Key words Whole-body impedance cardiography ; Thermodilution ; Direct oxygen Fick ; Cardiac output ; Haemodynamics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: To determine the reliability of whole-body impedance cardiography (ICGWB), with electrodes attached to wrists and ankles, in the measurement of cardiac output (CO) on the basis of simultaneous comparison with thermodilution (TD) and direct oxygen Fick (Fick) methods. Design: Prospective clinical study. Setting: A surgical intensive care unit at a university hospital. Patients: Thirty consecutive subjects undergoing a coronary artery bypass surgery were investigated preoperatively. Measurements: ICGWB derived CO was measured simultaneously with the TD and Fick methods to establish the biases and limits of agreement (LA) between the methods. Results: The results obtained by ICGWB and the invasive methods showed good agreement. The bias and LA between COTD and COICG were 0.00 l/min; –1.37 and 1.37 l/min, respectively, and were close to those obtained between COTD and COFICK, 0.32 l/min; 1.74 and –1.10 l/min. The bias and LA between the COFICK and COICG were –0.32 l/min; –2.24 and 1.60 l/min respectively. The repeatability value of consecutive single measurements for ICGWB (RVICG = 0.57 l/min) was much better than for the TD method (RVTD = 1.10 l/min). Conclusion: There was close agreement between the results of the three methods in the measurement of CO. In sedated preoperative patients the accuracy of ICGWB is within clinically acceptable limits and its repeatability is excellent. ICGWB provides a useful alternative to the TD and Fick methods in cases where the pressures supplied by the pulmonary artery catheter are not essential.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...