Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Biotechnology progress 7 (1991), S. 173-177 
    ISSN: 1520-6033
    Source: ACS Legacy Archives
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 729-739 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The state of fibrinogen adsorbed on untreated and glow-discharge-treated surfaces was examined by measuring platelet adhesion, monoclonal antibody (mAb) binding, the amount of fibrinogen adsorbed, and the amount of adsorbed fibrinogen which could be eluted with sodium dodecyl sulfate (SDS). Tetrafluoroethylene (TFE) glow-discharge-treated polymers have a lower surface free energy (in air) and retain a larger fraction of adsorbed fibrinogen than untreated surfaces after SDS elution. Platelet adhesion was lowest on the TFE-treated surfaces which retain the highest amounts of fibrinogen after SDS elution. Fibrinogen may undergo unfolding or spreading on the TFE-treated surfaces to minimize interfacial free energy (in water) and maximize protein-;surface interactions. When it is adsorbed on the TFE-treated surfaces, fibrinogen evidently assumes a state which somehow prevents its recognition and binding by platelet receptors. Monoclonal antibodies that bind to the three regions in fibrinogen thought to be involved in platelet adhesion were therefore used to detect changes in adsorbed fibrinogen. These regions and the antibodies which bind to them are: the COOH-terminal of the γ-chain, mAb M1; the RGD peptide sequence at Aα 95-98, mAb R1; the RDG sequence at Aα 572-575, mAb R2. For fibrinogen adsorbed on the untreated or TFE-treated surfaces, M1 and R2 binding was relatively high compared to background, while R1 binding was low. However, the amount of binding of each mAb to fibrinogen adsorbed on the TFE-treated surfaces was equal to or greater than fibrinogen adsorbed to the untreated surfaces. Therefore, antibody-detectable changes in the platelet binding regions of adsorbed fibrinogen that might have been caused by conformational or orientational rearrangements were not observed for the TFE-treated surfaces. The data suggest that the tight binding of fibrinogen on a surface may directly affect the ability of the fibrinogen to interact with the platelet receptors - i.e., that fibrinogen must be loosely held to facilitate maximal interaction with platelet receptors. © 1995 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 357-372 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Clinical applications of small-diameter synthetic vascular grafts are hindered by their highly thrombogenic surfaces. To develop vascular grafts that resist thrombotic occlusion, a radio frequency glow discharge (RFGD) process was employed to modify the surface of existing graft materials. Ultrathin coatings of RFGD polymers of ethylene (E), tetrafluoroethylene (TFE), and hexamethyldisiloxane (HMDS) were deposited on the lumen of Dacron grafts. Surfaces were characterized by electron spectroscopy for chemical analysis (ESCA). The effect of glow discharge treatments on plateletgraft interactions was evaluated in an ex vivo baboon shunt model. Following placement of an untreated or RFGD- treated graft in the shunt, deposition of 111Indium-labeled platelets was monitored for 60 min by γ camera imaging. Untreated Dacron rapidly accumulated large numbers of platelets, reaching a plateau i n 60 min. HMDS- and TFE-treated Dacron had significantly lower levels of platelet deposition compared to the untreated control. In contrast, the ethylene treatment of Dacron augmented platelet deposition, making it the most platelet- adherent surface studied. In vitro studies were also performed using untreated and RFGD-treated poly (ethylene terephthalate) (PET) coverslips. ESCA verified that the surface composition of the untreated and RFGD-treated coverslips were virtually identical to their untreated and treated Dacron graft counterparts. Samples were incubated in washed baboon platelet suspensions for 2 h at 37°C. Platelet adhesion on the untreated PET was relatively high, and many of the platelets had a completely spread morphology. The HMDS and TFE treatment of PET reduced the number of adherent platelets and prevented platelet spreading on the surface. Platelet adhesion and spreading on the ethylene-treated surface was the highest among the four studied. There is a remarkable linear correlation of the ex vivo and in vitro platelet adhesion data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...