Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 87 (2000), S. 6890-6892 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Annealing effects of CoCrTa and CoCrPt perpendicular magnetic recording media have been investigated. The coercivity and the squareness increase by postannealing when the annealing temperature is higher than 450 °C and CoCr35/TiCr10 dual underlayer is employed. The CoCr35 underlayer suppresses Ti diffusion to the magnetic layer and provides Cr up to the magnetic layer. The signal-to-noise ratio is improved and the magnetization irregularity diameter observed by magnetic force microscopy (MFM) decreases by the postannealing treatment. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 61 (1992), S. 2607-2609 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A magnetic force microscope (MFM) using a direct resonance frequency sensor which can be operated in the air has been developed. This instrument is simple and easy to handle because a vacuum system is not needed. The cantilever is used as a resonator in the oscillator, and its oscillating frequency is detected by a frequency modulation (FM) demodulator. A phase locked loop (PLL) FM demodulator is used which is less affected by noise. The cantilever is fabricated by Si microprocessing and its tip formed by precise focused ion beam (FIB) milling. MFM images demonstrate that this instrument has a performance almost the same as that which can be achieved in vacuum. It also has a scanning speed which is approximately 10 times as fast as that of an instrument using conventional slope detection techniques, and its signal-to-noise ratio is comparable to that of conventional systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...