Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: By application of pressure-tight vessels, the thermal effects of the evaporation of volatile components may be eliminated during differential thermal analysis. Such vessels, developed for the „Differential Scanning Calorimeter“, are described, and some characteristic measurements with a thermosetting phenolic compound are reported.
    Notes: Durch Verwendung druckdichter Behälter lassen sich bei der Differential-Thermoanalyse die von der Verdampfung flüchtiger Bestandteile herrührenden endothermen Effekte ausschalten. Derartige Behälter für das sogenannte „Differential Scanning Calorimeter“ werden beschrieben und einige charakteristische Messungen an einer Phenoplastmasse mitgeteilt.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Angewandte Makromolekulare Chemie 7 (1969), S. 181-193 
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: The thermal conductivity of the following homopolymers was measured or extrapolated from measurements on copolymers in the temperature range from - 180 to + 150°C: Polymethylmethacrylate, polyethylmethacrylate, poly-n-butyl-methacrylate, polymethylacrylate, polyethylacrylate, poly-n-butylacrylate, polystyrene, polyacrylonitrile.In all cases a flat maximum at the glass transition temperature was found, if the thermal conductivity was plotted over the temperature. The thermal conductivity of polyacrylonitrile, extrapolated from measurements on copolymers of methylmethacrylate and acrylonitrile, is greater than those of the other polymers as a consequence of hydrogene bonds.If the thermal conductivity of polymethacrylates and polyacrylates is plotted over the temperature difference T  -  TE, a decrease of the thermal conductivity with increasing length of the side chain will be found. Also increasing substitution of H-atoms in the polyethylene chain by Cl-atoms leads to a decrease in thermal conductivity at room temperature.By measurements on copolymers of methylmethacrylate and styrene, methylmethacrylate and methylacrylate, methylmethacrylate and acrylonitrile the thermal conductivity, plotted over the molar concentration, changes monotoneously between the values of the homopolymers of the two components. Only with copolymers of methylmethacrylate and styrene this change is linear.It may be generally concluded, that the thermal conductivity of a linear polymer, plotted over T  -  TE, will decrease, if units of the chain will be substituted by units of a greater mass (e. g. with longer side-chains etc.) without change of the intermolecular forces.
    Notes: Im Temperaturbereich von - 180 bis + 150°C wurde die Wärmeleitfähigkeit folgender Homopolymerer gemessen oder durch Extrapolation aus Messungen an Copolymeren ermittelt: Polymethylmethacrylat, Polyäthylmethacrylat, Poly-n-butylmethacrylat, Polymethylacrylat, Polyäthylacrylat, Poly-n-butylacrylat, Polystyrol, Polyacrylnitril.In allen Fällen findet man bei der Einfriertemperatur TE ein flaches Maximum der über der Temperatur T aufgetragenen Wärmeleitfähigkeit. Die durch Extrapolation aus der Wärmeleitfähigkeit von Methylmethacrylat-Acrylnitril-Copolymerren ermittelte Wärmeleitfähigkeit des Polyacrylnitrils liegt als Folge von Wasserstoffbrücken wesentlich höher als die der übrigen Polymeren.Trägt man die Wärmeleitfähigkeit der Polymethacrylate und Polyacrylate über der Temperaturdifferenz T  -  TE auf, so findet man durchweg einen Abfall der Wärmeleitfähigkeit mit zunehmender Seitenkettenlänge. Auch der zunehmende Einbau von Chloratomen an Stelle von Wasserstoff in der Polyäthylenkette führt zu einem Absinken der bei Zimmertemperatur gemessenen Wärmeleitfähigkeit.Bei Messungen an Methylmethacrylat-Styrol-, Methylmethacrylat-Methylacrylat und Methylmethacrylat-Acrylnitril-Copolymeren wurde gefunden, daß die über den molaren Anteilen der beiden Komponenten aufgetragene Wärmeleitfähigkeit monoton zwischen den Wärmeleitfähigkeiten der beiden Homopolymeren verläft. Nur bei Methylmethacrylat-Styrol-Copolymeren ist dieser Verlauf linear.Man kann allgemein folgern, daß die über T  -  TE aufgetragene Wärmeleitfähigkeit eines Linearpolymeren sinkt, wenn man Kettenbausteine durch solche mit größere Masse (z. B. mit längeren Seitengruppen o. ä.) ersetzt, ohne dabei die zwischenmolekularen Kräfte wesentlich zu verändern.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...