Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 66 (1962), S. 1513-1516 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 2073-2079 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design, construction, and evaluation of a combination spectrometer for measuring electronic absorption (EA), natural circular dichroism (CD), and magnetic circular dichroism (MCD) are described. Around the optical components of a JASCO ORD/UV-5 spectropolarimeter, a new EA/CD/MCD instrument was built with the realized intentions of increasing sensitivity and upgrading the analog tube type circuitry to a solid-state digitally, computer-controlled spectrophotometer. It is a flexible, dynamic, and user-controllable system, interfaced to an Apple II Plus computer, for studying instrument and signal parameters. The monochromator (M), photoelastic modulator (PEM), photomultiplier tube applied voltage (PMHV), and photomultiplier tube dc output current (PMdc) are under complete and independent software control. Our system has two unique aspects for obtaining the circular dichroism. First, the ac signal is measured with a voltage-to-frequency (V/f) converter; and, second, both the ac and the dc are independently recorded and their ratio is digitally calculated. This design has several advantages which include the elimination of voltage divider integrated circuits or division electronics, a wide dynamic range, a greater precision of ac values at low percentages of full scale, and the capability of continuous integration over long time periods. Also, both types of spectra, EA and CD or MCD, are obtained from the current output of the PM. This paper not only describes the design of the instrument for obtaining the two types of spectra but also compares four methods of obtaining the circular dichroism. Sensitivities of ∼1×10−7ΔA units are achievable as determined by measuring CD spectra of the well-known enantiomer (+)−[Co(en)3]3+.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 2785-2791 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A modular polarization spectrometry system for the measurement of the degree of polarization (linear or circular) of luminescence intensity is described. It is based on polarization modulation with a photoelastic modulator and two lock-in amplifiers for signal recovery. Interfaced to the spectrometer is a microcomputer configured with CRT monitor, disk drive, and digital printer to provide system control and to permit digital data storage and data manipulations such as multiple scan averaging and averaged background subtraction. The system described is capable of measuring linearly polarized emission, linearly polarized excitation luminescence, and circularly polarized emission spectra. The modular design also allows the spectrometer to be rapidly and easily modified for the measurement of circular dichroism, magnetic circular dichroism, or magnetic circularly polarized emission. The system performance is demonstrated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 3827-3828 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A stable high-current transistor-based regulator has been designed to stabilize 450-W dc xenon arc lamps. The circuit employs commercially available components. The regulator provides stabilization beyond that found in commercial optical instruments. The improvements using this circuit are a 0.20% ac-to-dc regulation representing a 44% decrease in the peak-to-peak ac ripple, achievement of nondrifting dc level, and being able to use the spectrometer immediately following lamp ignition.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of agricultural and food chemistry 37 (1989), S. 18-22 
    ISSN: 1520-5118
    Source: ACS Legacy Archives
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food science 53 (1988), S. 0 
    ISSN: 1750-3841
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A myosin/actomyosin mixture (MAM), actomyosin and myosin were isolated from post-rigor turkey. Rheological properties of MAM gels were determined by uniaxial compression. Breast MAM formed gels which were stable at lower protein concentrations (10 and 15 mg/mL) than thigh MAM (20 and 25 mg/mL). Differential scanning calorimetry (DSC) and a fluorescent hydrophobic probe, 8-anilino-l-napthalene sulfonate (ANS), were used to study thermal transitions. One DSC peak was observed in breast and thigh MAM. ANS thermograms showed that thigh actomyosin had a greater transition temperature (Tr) (51.8°C) than breast actomyosin (49.7°C). The ANS Tr was 48°C for both myosins. The difference in gelation appeared to be associated with protein-protein interactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Cellular Physiology 107 (1981), S. 329-334 
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: The objectives of this investigation were to produce a reliable, senstive probe to measure intracellular PO2 with a high degree of resolution and to apply this technique to biological systems. A fluorescent molecule, pyrene dissolved in paraffin oil, was encapsulated in polyacrylamide to form a probe of nanometer dimensions. The quantitative and microscopic oxygen values were determined by analyzing the quenching of the fluorescence of the probe by oxygen, as displayed on a television monitor by a silicon-intensified-target camera. The nanocapsules had a sensitivity of approximately 1 mm PO2, a spatial resolution of 0.5 μm, and a temporal resolution of milliseconds. Calibrated nanocapsules within nonrespiring Amoeba proteus responded to ambient partial pressures of oxygen. At two different ambient partial pressures, nanocapsules engulfed by respiring amoebas indicated an intracellular PO2 28 mm Hg less than extracellular PO2. The capsules retained their sensitivity to oxygen for at least 8 months.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...