Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of interventional cardiology 14 (2001), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Before intervention, a detailed echocardiographic examination is mandatory for the decision whether this procedure will be necessary, possible, and safe. During intervention, transesophageal echocardiography (TEE) is needed for the continuous monitoring of the procedure, immediate assessment of results, and complications. TEE results in a significant reduction of fluoroscopy time. After intervention, echocardiography provides information on long-term results and newly developed complications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5020 , USA , and P.O. Box 1354, Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of interventional cardiology 18 (2005), S. 0 
    ISSN: 1540-8183
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Nonsurgical closure of congenital and acquired ventricular septal defects (VSD) has become increasingly acceptable with the availability of various occlusion systems that allow percutaneous treatment of muscular and membranous defects. This study describes a series of 12 patients (0.2–74-years-old) who underwent defect closure with six different occlusion systems. Device selection according to anatomy and outcome is highlighted. Seven VSDs were located in the membranous part of the septum, five in the mid-muscular septum. Complex heart lesions were present in five postmyocardial infarction VSD in one and residual postsurgical defects in three patients. The size of the VSD ranged from 2.6 to 10 mm. The applied devices were: Amplatzer muscular VSD occluder (n = 4), Amplatzer septal occluder (n = 2), Amplatzer duct occluder (n = 1), Amplatzer membranous VSD occluder (n = 2), Nit-Occlud coil (n = 2), and Cook PDA coil (n = 1). The devices were implanted successfully in nine patients. There was complete VSD closure in eight patients within the first 24 hours. In one patient, a trivial residual shunt disappeared at 6 months follow-up. Because of device instability, two occluders were removed during catheterization. In two other cases, tricuspid valve tissue was entrapped in the occluder and had to be removed surgically, one of them during the consecutive Rastelli operation. Neither significant arrhythmia, nor thromboembolism or hemolysis occurred in out patients during follow-up. Transcatheter closure of VSD is an attractive alternative to surgery. In complex congenital heart disease, surgical-interventional hybrid therapy may improve morbidity and total outcome. The recently developed Amplatzer VSD devices allow closure of muscular and membranous VSDs. Implantation and short-term follow-up are superior to the formerly used devices. Long-term effects have to be evaluated in further studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-086X
    Keywords: Key words: PDA〈+〉—〈+〉Catheter occlusion〈+〉—〈+〉Memory-shaped coils〈+〉—〈+〉Newborn piglets〈+〉—〈+〉Stents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Purpose: To examine the feasibility of transvenous placement of a new memory-shaped, small, retrievable coil that has a smaller-caliber delivery system than currently available devices, for closure of the patent ductus arteriosus (PDA). Methods: Through 4 or 5 Fr vascular sheaths and 4 or 5 Fr end-hold catheters, the coils were delivered and placed in piglets (n= 10) with PDA. The coils were made from 0.018″ (0.46 mm) or 0.028″ (0.71 mm) stainless steel guidewire. Mounted for delivery, the new device has the appearance of a conventional guidewire. This neonatal PDA model was created without major surgery or drugs by stenting the ductus arteriosus. Results: The memory-shaped coils were easily delivered. Coils not optimally placed were retrieved and repositioned. Occlusion of the ductus arteriosus as early as a half-hour after delivery was shown angiographically and confirmed by histopathology. Conclusion: This new, small-caliber, simple device was found to be effective for closure of the PDA in this animal model. Longer-term observations are needed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...