Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract An internal monostandard method for PGAA is proposed for completely non-destructive analysis of elements in bulky samples by the use of a neutron beam guided out from the reactor. The method is essentially the same as the k 0 method except that it corrects for the change of relative γ-ray counting efficiencies caused by the absorption and scattering of neutrons and absorption of γ-rays within the sample. Some examples of applications to archaeological samples of earthen wares, bronze mirrors, and to voluminous meteorite samples are demonstrated, and its future application to the in-situ studies of distribution and metabolism of a certain elements in animals is also explained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Neutron-induced prompt gamma-ray analysis (PGA) was applied to seven meteorite samples (Allende, Zagami, Acfer 209, ALH77005, ALH84001, EET79001 and Neagari). Samples were irradiated in both the thermal neutron and the cold neutron guided beams of JRR-3M at JAERI. Multiple samples of an Allende standard powder were analyzed for Si using two different methods: (1) the comparison method, using a Si standard, and (2) the mono-standard method, using Fe as an internal reference element. The Si concentrations determined by these two methods are in good agreement with literature values. The analytical sensitivity for Si using the cold neutron guided beam is∼14.3× higher than that for the thermal neutron guided beam. Other elements determined (B, Ca, Ti and S) also showed higher sensitivities using the cold neutron beam. The other meteorites studied showed some anomalous B and S values likely due to the effects of terrestrial weathering/contamination.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...