    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 20 (1997), S. 119-121 
    ISSN: 0935-6304
    Keywords: Concentrators ; Fast accumulation ; Sulfur compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effects of the sample flow-rate and bulk and bulk sample composition on the breakthrough behaviour of H2 in small sorption traps were studied. The information is required for the bulk thermal properties of the sample affect the temperature inside the cooled traps and therefore also the breakthrough volume. It was also found that the brakthrough volume, measured downstream of a packed trap, can qctually increase with volume flow rate.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 217-223 
    ISSN: 0935-6304
    Keywords: High speed chromatography ; Sulfur compounds ; Photoionization detection ; Trace analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: There is a need for rapid, on-line, gas chromatographic analysis of trace levels of hydrogen sulfide and carbon oxysulfide in the oil-from-coal industry. In order to improve an existing method based on a polymer bed concentrator, a porous layer open tubular column, and a flame photometric detector, time-optimization of the various steps involved was attempted. Use of a redesigned concentrator, changed column operating conditions, and a photoionization detector reduced analysis times from 6.5 to 3 min and cycle times from 8 to 3 min. This could be achieved without compromising the 10 ppb detection limit required.
    Additional Material: 11 Ill.