Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 3 (1992), S. 313-313 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 59 (1996), S. 91-98 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The structural characterization for five currently used prosthetic-orthotic polymers, determined by proton (1H) nuclear magnetic resonance spectroscopy, showed residual unsaturation, C=C groups, in all materials, ranging from 1.7 to 15%. The determination of residual unsaturation by 1H-NMR spectroscopy in polymers contributes information that may be useful for: (1) quality control of batches of materials. and (2) the development of standards, test methods necessary to evaluate the effects of environmental influences associated with long-term clinical service. Materials selected for current usage were: Durr-Plex (polyethylene terephthalate), polypropylene, Subortholen (polyethylene), Surlyn (ethylene methacrylate ionomer), and Uvex (cellulose acetate butyrate). © 1996 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 60 (1996), S. 2025-2032 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The suitability of a combination of an infrared spectral search program and three commercially available infrared spectral data bases to structurally identify prosthetics/orthotics polymers was assessed. Five currently used prosthetics/orthotics polymers subjected to a simulated clinical fabrication heat treatment were examined using diffuse reflectance. The polymers selected were Durr-Plex (polyethylene terephthalate), polypropylene, Subortholen (polyethylene), Surlyn (ethylene methacrylate ionomer), and Uvex (cellulose acetate butyrate). The combination of a spectral search program and three commercially available data bases was inadequate for structural identification of these prosthetics/orthotics poly in their simulated clinical fabrication heat-treated condition and may be misleading. Benefits of creating effective combinations of spectral search software and appropriate and more comprehensive data bases with specific entries for prosthetics/orthotics polymers would be for: (1) quality control of batches of polymers, and (2) the development of standards, test methods necessary to evaluate the effects of environmental influences associated with long-term clinical service. © 1996 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The effects of simulated clinical fabrication heat treatment and artificial weathering on the degree of crystallinity for three prosthetics/orthotics polymers were monitored by wide-angle x-ray diffraction. The polymers selected, polypropylene(PP), Subortholen (polyethylene, SB), and Surlyn (polyethylene methacrylate copolymer, SR), represent commonly used semicrystalline materials. Analysis of the as-received polypropylene showed no preferred orientation of the crystallites. The materials were examined in the as-received and simulated clinical fabrication heat-treated conditions. The simulated clinical fabrication heat-treated specimens were subsequently treated to 2 weeks, 4 weeks, and 8 weeks of artificial weathering conditions. The artificial weathering consisted of exposure to cycles of ultraviolet light and heated condensation. The degree of crystallinity was calculated and correlated with the materials structure, and ranged from 13.7 to 64.5% with an order from low to high of SR 〈 SB 〈 PP. The x-ray diffraction technique was demonstrated to be a useful tool for detecting environmental influences on prosthetics/orthotics polymers. © 1996 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The tensile behavior was compared for five prosthetics/orthotics polymers: Durr-Plex (co-polyester), Polypropylene (polypropylene), Subortholen (polyethylene), Surlyn (ionomer), and Uvex (and cellulose acetate butyrate). Tensile properties, yield strength, and modulus of elasticity are related to a number of factors including composition and condition of polymers. The polymers were examined in the as-received and simulated clinical fabrication heat-treated conditions. The simulated clinical fabrication heat-treated specimens were subsequently treated to 2 weeks, 4 weeks, and 8 weeks of artificial weathering conditions, consisting of exposure to cycles of ultraviolet light and heated condensation. Tensile testing was performed on an Instron mechanical testing system, until fracture occurred. The ranges and respective rankings of yield strength and modulus of elasticity in tension were determined. Analysis of Variance (ANOVA) and post hoc Scheffé statistical analyses were performed for different polymers of the same treatment condition, and different treatment conditions of the same polymer. The analysis of variance (ANOVA) showed significant yield strength and modulus differences for the five polymers. The choice of material significantly influences the tensile properties for prosthetics/orthotics polymers. The Uvex polymer had the highest yield strength and elastic modulus, and the Surlyn polymer had the lowest yield strength and elastic modulus. The ranking trend was Uvex 〉 Durr-Plex 〉 polypropylene 〉 Subortholen 〉 Surlyn. © 1996 John Wiley & Sons, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The hardness behavior was compared for five prosthetics/orthotics polymers: Durr-Plex (copolyester), Polypropylene (polypropylene), Subortholen (polythylene), Surlyn (ionomer), and Uvex (and cellulose acetate butyrate). The hardness is related to a number of factors including the composition and condition of the polymers. The polymers were examined in the as-received and simulated clinical fabrication heat-treated conditions. The simulated clinical fabrication heat-treated specimens were subsequently treated to 2 weeks, 4 weeks, and 8 weeks of artificial weathering conditions, consisting of exposure to cycles of ultraviolet light and heated condensation. Five measurements were taken for each treatment condition using a Durometer hardness tester. The hardness ranges and the respective ranking for the polymers were determined. Analysis of variance (ANOVA) and post hoc Scheffé statistical analyses were performed for different polymers of the same treatment condition, and different treatment conditions of the same polymer. The analysis of variance (ANOVA) showed significant hardness differnces for the five polymers. The choice of material significantly influences the mechanical property of hardness for prosthetics/orthotics polymers. The Durr-Plex polymer had the highest hardness and the Surlyn polymer had the lowest hardness. The ranking trend was Durr-Plex〉Uvex〉polypropylene〉Subortholen〉Surlyn. © 1996 John Wiley & Sons, Inc.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Interfaces were formed between acrylic bone cement and three commonly used surgical alloys (316L SS, Co—Cr—Mo, and Ti—6A1—4V), in an attempt to further define cementation parameters of acrylic bone cement for use in orthopaedic surgery. Metal/cement interfaces were made at three distinct times during the setting cycle of the cement and were cured for 1 hr, 1 day, and 1 week. The metals were prepared with roughly polished or finely polished prepassivated surfaces. Tensile bond strengths and residual cement on metal coverage data indicated that, for each metal system, interfaces created prior to and at the onset of the dough stage formed superior interfaces for implanation compared to those formed late in the dough stage. Furthermore, electropolishing plus prepassivation offered a more efficient bonding surface than mechanical polishing.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 1131-1139 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The corrosion resistance of 316L cold worked stainless steel depends upon its thin protective oxide layer; and if this is partially broken down, corrosion resistance depends upon its tendency for repassivation. Since the intended function of stainless-steel implants is to sustain musculoskeletal forces, research toward the stability of the oxide film during dynamic loading in simulated bodylike fluids is warranted. A pilot corrosion fatigue study was, therefore, performed on uniaxial tension fatigue specimens cycled to various maximum stress levels near their yield point while immersed in 37°C isotonic saline solution, and combined with the electrochemical insult of (a) imparting an 800 mV vs. SCE anodic potential for 20 s to stimulate local film breakdown, and then (b) returning to a constant 200 mV vs. SCE anodic potential and maintaining that potential during cyclic loading until the specimens broke in two. During the anodic polarization by continuously monitoring the current it was possible to (a) observe the repassivation and corrosion behavior following stimulation, and (b) detect crack initiation, crack propagation and failure onset. The combined effects of accelerated corrosion and mechanical fatiguing disturbed the repassivation tendency and reduced the crack initiation times and the fatigue lives as compared to air and saline controls. As the maximum cyclic load levels were increased, the fatigue lives were further foreshortened.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 27 (1993), S. 1357-1366 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The Scanning Electrochemical Microscope (SECM) is a nonoptical scanning microscopic instrument capable of imaging highly localized electrical currents associated with charge transfer reactions on metallic biomaterials surfaces. The SECM operates as an aqueous electrochemical cell under bipotentiostatic control with a microelectrode and sample independently biased as working electrodes. Microelectrode current and position is recorded as it is scanned very near a metallurgically polished planar sample surface. To date, the SECM has imaged metallic biomaterials surfaces in oxygen reaction rate imaging (ORRI) and ion release and deposition imaging (IRDI) modes. In ORRI, sample and microelectrode are biased at sufficiently negative potentials to reduce absorbed oxygen. As the microelectrode scans areas of active oxygen reduction, localized diffusion fields with decreased oxygen solution concentrations are encountered and resultant decrements in microelectrode current are observed. In IRDI mode the sample is positively biased and the microelectrode is negatively biased. The microelectrode detects anodic dissolution products with highest currents being observed over the most active areas. Performance of the SECM has been evaluated on Ni minigrids, γ-1 Hg-Ag dental amalgam crystals, and sintered beads of Co-Cr-Mo alloy which represent significantly different geometries and corrosion processes to help demonstrate the potential of this instrument. The SECM is a valuable tool for imaging microelectrochemical processes on the surfaces of metallurgically polished metallic biomaterials samples and a wide variety of other surfaces of biological interest where charge transfer reactions occur. The SECM allows selective biasing of metallic biomaterials surfaces and Faradaic reactions can be selectively imaged while the surface is in the active, passive, or transpassive state. © 1993 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 441-453 
    ISSN: 0021-9304
    Keywords: composite ; bone cement ; flexure ; fracture toughness ; gamma irradiation ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Loosening remains an impediment to the long-term success of total hip replacements despite numerous improvements in the materials used. In cemented prostheses, fatigue and fracture of bone cement have been implicated in the failure of these devices. A new material, self-reinforced composite poly(methyl methacrylate) (SRC-PMMA), has been developed. SRC-PMMA is formed by a novel processing method that will be described. The composite consists of high strength, highly oriented PMMA fibers embedded in a matrix of PMMA. Using a woven form of SRC-PMMA, an in vitro physical and mechanical evaluation was performed to assess the feasibility of its use in an orthopedic prosthesis. Three different weaves of SRC-PMMA were evaluated in bending and fracture toughness in air, after immersion for 30 days in 37°C saline, and after gamma irradiation followed by immersion. Bending modulus and strength were decreased by gamma irradiation followed by saline immersion. The effect of saline immersion alone on bending strength and modulus was negligible. Saline immersion and gamma irradiation followed by saline immersion was shown to have little or no effect on the fracture toughness of woven SRC-PMMA. Differences in the fracture processes of the different weaves were found and can be related to the differing orientation of fibers to the fracture toughness pre-crack. Optimally incorporated SRC-PMMA absorbs the same amount of water as bone cement. Comparison to previous and current work with bone cement controls shows that SRC-PMMA is a material equal to or better than bone cement in all tests performed. It deserves further consideration as a candidate biomaterial. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 441-453, 1997.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...