ISSN:
0006-3592
Keywords:
microtechnique
;
microprobe
;
biofilm
;
dissolved oxygen concentration
;
Chemistry
;
Biochemistry and Biotechnology
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Biology
,
Process Engineering, Biotechnology, Nutrition Technology
Notes:
A novel in situ microtechnique allows evaluating parameters of diffusion-controlled reactions in biofilms. A microprobe, 15 μm in diameter, was used to simultaneously measure the dissolved oxygen concentration and the optical density at different depths in a submerged biofilm. Based on the results, the biofilm diffusion coefficient for dissolved oxygen, Df the dissolved oxygen flux through the biofilm surface, J02, and the half velocity coefficient, Ks, have been calculated.
Additional Material:
7 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/bit.260380809