  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 673-675 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The crossover electron beam ion source (XEBIST) without confining magnetic field has made an important step towards higher electron beam energies. By proper matching using a magnetic lens system, a high compression of the electron beam has been achieved. The importance of reducing the lens aberrations by partial neutralization of the beam space charge in the lens section has been demonstrated. The effective current density in the trap region has been further increased by self-pinching in connection with space-charge neutralization. In our first experiments at an electron energy of 22 keV, the average current density in the trap increased from 10 to 150 A/cm2 at 40 ms neutralization time. Highly charged ions like Ar17+ were produced in this way. The combined Penning ion trap and electron beam source (PITEBIS) was operated successfully by radio-frequency modulating the current of the electron beam. This new kind of modulation could be used not only for cleaning EBIS sources from unwanted ion species but also to enhance the yield of highly charged ions by ion cooling. The effect of selective rf heating is demonstrated. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The Frankfurt superconducting electron beam ion source (EBIS) is under reconstruction for higher ion yield by employing an immersed gun with a 2-mm-diam cathode for a 3 A electron beam. The trap electrode construction is as simple as possible to avoid any rf production. The ion extraction will be similar to the one applied in our MEDEBIS, using tapered electrodes to create a high axial extraction gradient. Research was continued on the use of oscillating electrons to reduce the power requirements of the beam, investigating the formation of a virtual cathode by decelerating the beam at full magnetic field strength while operating the gun under immersed flow conditions with adjustable compression. The MEDEBIS has proven its quality and reliability for the application as an injector for a medically dedicated synchrotron. To improve its yield of bare nuclei, better vacuum conditions are provided by drilling out the inner windings of the warm solenoid to allow for the installation of higher vacuum conductance. After the successful presentation of our XEBIST principle that delivers highly charged ions as Ar18+ and Ba46+ we have now shown its application for the production of singly charged ions as an injector of metallic ions. Finally, an EBIS/T with an internal Penning trap has been constructed to prepare selected ion species and charge states inside the ionization region. This new device will allow the study of electron–ion interactions in well-defined initial and final charge states, i.e., to be able to distinguish between single and multiple step ionization. If the homogeneity of the magnetic field in the trap region will reach 10−9, the determination of binding energies of highly charged ions may be better than a 1 eV accuracy. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: With electron beam ion sources/traps (EBIS/T) ions with highest charge states can be produced. EBIT represents a successful device for atomic physics studies, while EBIS is also an injector to accelerate highly charged ions of every species. High performance EBIS/T usually uses a high magnetic field generated by superconducting coils to compress the electron beam, in order to obtain high electron beam current densities in the range of 102–103 A/cm2 along the ionization region. Studies on a crossover (X-) EBIS without magnetic field but using an electrostatically generated electron beam crossover have shown the production of highly charged ions like Ar18+ and Ba46+. A project was started to yield high current densities from the self pinching of a relativistic electron beam in a partially space charged compensated region. A 65 keV electron beam is produced by a high emissive cathode with the lowest possible beam emittance and is focused by magnetic lenses into the trap region, where the electronic space charge will be compensated by trapped ions. The current density produced by the crossover will be enhanced by the self pinching of the relativistic electron beam. Axial ion extraction optics and radial diagnostics in the ReXEBIST (relativistic XEBIS/T) allow both, EBIS and EBIT operation. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Clinical & experimental allergy 32 (2002), S. 0 
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background Single exposures to 〉 200 p.p.b. of ozone are capable of enhancing the early-phase lung function response to allergen.Objective The aim of the present study was to compare the effect of single vs. repeated exposures to ozone on early and late-phase allergen responses.Methods Eleven subjects with allergic asthma and 22 subjects with allergic rhinitis underwent single exposures to filtered air, 125 p.p.b. and 250 p.p.b. ozone, as well as repeated exposures to 125 p.p.b. ozone on four consecutive days. Twenty hours after the (final) exposure, subjects inhaled a single dose of allergen and a sputum induction was performed 6–7 h later.Results In the subjects with rhinitis, the mean early-phase response of FEV1 and the number of ≥ 20% reductions were significantly greater after exposure to 250 or 4 × 125 p.p.b. ozone compared with filtered air. In addition, most of the ≥ 15% late-phase responses in FEV1 occurred after exposure to 4 × 125 p.p.b., as well as the strongest effects on sputum parameters. The rise in the number of eosinophils was statistically significant in both groups. Regarding the number of lymphocytes and the concentrations of mast cell tryptase, histamine or LDH, significance was, however, only reached in the asthma group.Conclusion Our data suggest that repeated exposure to ozone, at a peak ambient air level, can enhance both functional and inflammatory responses to inhaled allergen in subjects with pre-existing allergic airway diseases, and that these effects might reach a clinically relevant magnitude.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science, Ltd
    Clinical & experimental allergy 31 (2001), S. 0 
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background Among the reasons that restrict the application of sputum induction in outpatient settings is the need for processing of samples within 2 h after induction.Objective The aim of our study was to assess whether freezing is suitable for intermediate storage of sputum samples before processing.Methods We compared differential cell counts between two sputum aliquots derived from the same sample. One aliquot was processed within 2 h after production and one, after it had been frozen under addition of dimethyl-sulfoxid (DMSO) and stored up to 10 days at −20 °C. Thirty-five samples were frozen immediately prior to preparation of cytospins, and 10 samples were frozen at an even earlier stage, directly after homogenization.Results In both sets of experiments we observed a significant relationship between frozen and native samples regarding macrophages, neutrophils and eosinophils, as indicated by respective intraclass correlation coefficients of 0.96, 0.96, and 0.93 in the first, and of 0.92, 0.96 and 0.77 in the second experiments.Conclusion Our results indicate that the freezing of sputum samples at different stages of processing does not alter sputum morphology to an extent that affects the results of differential cell counts.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie in unserer Zeit 8 (1974), S. 184-190 
    ISSN: 0009-2851
    Keywords: Chemistry ; Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability