  • 1
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: ICDs are the therapy of choice in patients with life-threatening ventricular arrhythmias. Mortality, morbidity, and complication rates including appropriate and inappropriate therapies are unknown when ICDs are used in routine medical care and not in well-defined patients included in multicenter trials. Therefore, the data of 3,344 patients ( 61.1 ± 12.1  years ; 80.2% men; CAD 64.6%, dilated cardiomyopathy 18.9%; NYHA Class I–III: 19.1%, 54.3%, 20.1%, respectively; LVEF 〉 0.50 : 0.234, LVEF 0.30–0.50: 0.472, LVEF 〈 0.30 : 0.293, respectively) implanted in 62 German hospitals between January 1998 and October 2000 were prospectively collected and analyzed as a part of the European Registry of Implantable Defibrillators (EURID Germany). The 1-year survival rate was 93.5%. Patients in NYHA Class III and a LVEF 〈 0.30 had a lower survival rate than patients in NYHA Class I and a preserved LVEF (0.852 vs 0.975, P = 0.0001 ). Including the 1-year follow-up, 49.5% of patients had an intervention by the ICD, 39.8% had appropriate ICD therapies, 16.2% had inappropriate therapies. Overall, 1,691 hospital readmissions were recorded. The main causes for hospital readmissions were ventricular arrhythmias (61.3%) and congestive heart failure symptoms (12.9%). Thus, demographic data and mortality of patients treated with an ICD in conditions of standard medical care seems to be comparable and based on, or congruent with, the large secondary preventions trials. When ICDs are used in standard medical care, the 1-year survival rate is high, especially in patients with NYHA Class I and preserved LVEF. However, nearly half of all patients suffer from ICD intervention. (PACE 2003; 26[Pt. I]:1511–1518)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: New developments in dual chamber implantable cardioverter defibrillators (ICD) have increased the specificity of therapy delivery. This study was performed to examine the performance of an algorithm, focusing on its ability to distinguish slow ventricular tachycardia (VT) from sinus rhythm or supraventricular tachyarrhythmias. The patient population included 77 men and 13 women, 63 ± 11 years old, treated with ICDs after episodes of spontaneous or inducible ventricular tachyarrhythmias. They were randomized to programming of the ICD to a lower limit of VT detection at 128 beats/min (group I, n = 44), versus 153 beats/min II (group II, n = 46). The primary endpoint of the study consisted of comparing the specificity and sensitivity of the algorithm between the two groups of patients. Over a 10.1 ± 3.5 months follow-up, 325 episodes were detected in the Tachy zone in group I, versus 106 in group II. The sensitivity and specificity of the algorithm in group I were 98.8% and 94.4%, respectively, versus 100% and 89% in group II (NS). A single episode of VT at a rate of 132 beats/min was diagnosed as SVT in group I. The sensitivity and specificity of the algorithm for tachycardias 〈153 beats/min were 97.4% and 94.5%, respectively. Overall VT therapy efficacy was 100% in both groups. The performance of this algorithm in the slow VT zone supports the programming of a long Tachy detection interval to document slow events, and allows to treat slow VT, if necessary, without significant risk of inappropriate interventions for sinus tachycardia. (PACE 2003; 26:2275–2282)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 27 (2004), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Inappropriate therapy remains an important limitation of implantable cardioverter defibrillators (ICD). PARAD+ was developed to increase the specificity conferred by the original PARAD detection algorithm in the detection of atrial fibrillation (AF). To compare the performances of the two different algorithms, we retrospectively analyzed all spontaneous and sustained episodes of AF and ventricular tachycardia (VT) documented by state-of-the-art ICDs programmed with PARAD or PARAD+ at the physicians' discretion. The results were stratified according to tachycardia rates 〈150 versus ≥150 beats/min. The study included 329 men and 48 women (64 ± 10 years of age). PARAD was programmed in 263, and PARAD+ in 84 devices. During a mean follow-up of 11 ± 3 months, 1,019 VT and 315 AF episodes were documented among 338 devices. For tachycardias with ventricular rates 〈150 beats/min, the sensitivity of PARAD versus PARAD+ was 96% versus 99% (NS), specificity 80% versus 93% (P 〈 0.002), positive predictive value (PPV) 94% versus 91% (NS), and negative predictive value (NPV) 86% versus 99% (P 〈 0.0001). In contrast, in the fast VT zone, the specificity and PPV of PARAD (95% versus 84% and 100% versus 96%) were higher than those of PARAD+ (NS, P 〈 0.001). Among 23 AF episodes treated in 16 patients, 3 episodes triggered an inappropriate shock in 3 patients, all in the PARAD population. PARAD+ significantly increased the ICD algorithm diagnostic specificity and NPV for AF in the slow VT zone without compromising patient safety.