Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1432-2218
    Schlagwort(e): Key words: Gasless endoscopic vascular prosthesis implantation — transperitoneal versus extraperitoneal approach — in vitro fluid tightness evaluation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: The goal of this acute experimental study was to demonstrate the practicability and reproducibility of aortobifemoral bifurcational prosthesis implantations via either a transperitoneal or extraperitoneal approach using gasless videoendoscopic instrumentation. The endoscopically sutured end-to-side aortic anastomoses were also examined for fluid tightness. Methods: Eighteen of the 20 domestic pigs in this experimental study received aortobifemoral vascular prostheses in a gasless videoendoscopic procedure. Bursting pressures and leakage (ml/min) were compared for the endoscopically sutured aortic end-to-side anastomoses versus those sutured in conventional techniques using 6-h-old porcine aortas and 6-mm prostheses. Results: The surgical procedures averaged 4 h for the transperitoneal approach (n= 9) and 4.5 h for the extraperitoneal approach (n= 9). However, these times were significantly reduced with increasing routine. Average aortic occlusion times were 1 h for the transperitoneal approach and 1 h 15 min for the extraperitoneal approach; the average iliacofemoral occlusion time ranged from 1 h 45 min with the transperitoneal approach to 1 h 15 min with the extraperitoneal approach, depending on which side was involved. There were no significant differences in in vitro bursting pressure or leakage amounts between endoscopic and conventionally sutured aortic end-to-side anastomoses. Conclusions: Gasless videoendoscopic implantation of aortobifemoral vascular prostheses in animal subjects is both practicable and reproducible using either a transperitoneal or extraperitoneal approach. The extraperitoneal approach has proven advantages over the transperitoneal approach. The in vitro fluid tightness achieved with endoscopically sutured aortic end-to-side anastomoses is comparable to conventionally sutured anastomoses.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1435-2451
    Schlagwort(e): Key words Gasless videoendoscopic vascular surgery ; Aortobifemoral prosthesis ; Extraperitoneal approach ; Schlüsselwörter Gaslose videoendoskopische Gefäßchirurgie ; Aortobifemorale Gefäßprothese ; Extraperitonealer Zugang
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung An der Chirurgischen Universitätsklinik Köln wurde die gaslose videoendoskopische Implantation aortobifemoraler 6×6 mm2 im Durchmesser betragender beschichteter Gelsoft-Bifurkationsprothesen über einen extraperitonealen Zugang im Akutversuch an 10 Hausschweinen erprobt. Das gaslose videoendoskopische Operieren wurde durch ein Laparolift-Laparofan-System ermöglicht. Bei insgesamt 9 von 10 Tieren konnte erfolgreich eine aortbifemorale beschichtete Gelsoftgefäßprothese implantiert werden. Ein Tier verstarb noch vor Beginn der Operation während der Einleitung an einem massiven Herzinfarkt. Die durchschnittliche Gesamtoperationszeit betrug 270 min. Die Präparationszeit der infrarenalen Aorta bis zum Ausklemmen betrug im Mittel 45 min. Die durchschnittliche Abklemmzeit der Aorta betrug 75 min. Die mittlere iliakofemorale Abklemmzeit lag bei extraperitonealem Zugang für die linke Seite bei 45 min, für die rechte Seite bei 75 min. Nach erfolgreicher endoskopischer Bifurkationsprothesenimplantation erfolgte die Laparotomie und Resektion des aortobifemoralen Prothesensegments mit Originalstrombahn. Zur Überprüfung der Dichtigkeit wurden in vitro unter künstlicher Zirkulation eines Ringer-Laktat-Glyzerin-Gemisches die Leckage/min sowie der Berstungsdruck der endoskopisch genähten aortalen End-zu-Seit-Anastomosen untersucht und mit konventionell genähten End-zu-Seit-Anastomosen zwischen 6 h alten Schweineaorten und einer 6 mm im Durchmesser betragenden beschichteten Gelsoftprothese verglichen. Der maximale Berstungsdruck aller endoskopisch genähten Anastomosen lag bei 480 mmHg systemischem Mitteldruck, der niedrigste Berstungsdruck lag bei einem systemischen Mitteldruck von 140 mmHg. Minimal lag die Leckage/min bei systolischen Druckwerten von 120 – 350 mmHg 〈10 ml/min. Sämtliche endoskopisch genähten aortalen End-zu-Seit-Anastomosen waren in der In-vitro-Dichtigkeitsprüfung hinsichtlich Berstung und Leckage/min durchaus mit den konventionell genähten Anastomosen vergleichbar.
    Notizen: Abstract The gasless videoendoscopic implantation of GELSOFT aortobifemoral vascular prostheses times 6×6 mm in diameter using an extraperitoneal approach was tested in ten porcine experimental models at the Surgical Department of the University of Cologne, Germany. Gasless videoendoscopic surgery is performed with a laparolift-laparofan system. Aortobifemoral GELSOFT prostheses were successfully implanted in nine of ten animals, whereby one animal died during preparations for surgery of massive coronary infarctions. Average surgical durations using the extraperitoneal approach were 270 min. Dissection of the infrarenal aorta until occlusion took 45 min, average aortic occlusion 75 min, and iliacofemoral occlusion 45 min for the left side and 75 min for the right side. After successful videoendoscopic implantation of aortobifemoral GELSOFT prostheses all nine animals underwent laparotomy and resection of the aortobifemoral prosthetic segment. The quality of the endoscopically sutured aortic end-to-side anastomoses was examined in vitro under artificial circulation of glycerol/Ringer's lactate solution for evaluation of possible leakage and bursting pressures and then compared to conventionally sutured end-to-side anastomoses of 6-h-old porcine abdominal aorta and GELSOFT prostheses 6 mm in diameter. The maximum bursting pressure of all endoscopically sutured anastomoses was 480 mmHg mean pressure; the minimum was 140 mmHg mean pressure. The minimum leakage per minute was less than 10 ml/min for systolic pressure values between 120 and 350 mmHg. All endoscopically sutured aortic end-to-side anastomoses were comparable to conventionally sutured anastomoses concerning in vitro evaluation of bursting pressure and leakage per minute.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1435-2451
    Schlagwort(e): Gasless videoendoscopic vascular surgery ; Aortobifemoral prosthesis ; Extraperitoneal approach ; Gaslose videoendoskopische Gefäßchirurgie ; Aortobifemorale Gefäßprothese ; Extraperitonealer Zugang
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung An der Chirurgischen Universitätsklinik Köln wurde die gaslose videoendoskopische Implantation aortobifemoraler 6×6 mm2 im Durchmesser betragender beschichteter Gelsoft-Bifurkationsprothesen über einen extraperitonealen Zugang im Akutversuch an 10 Hausschweinen erprobt. Das gaslose videoendoskopische Operieren wurde durch ein Laparolift-Laparofan-System ermöglicht. Bei insgesamt 9 von 10 Tieren konnte erfolgreich eine aortbifemorale beschichtete Gelsoftgefäßprothese implantiert werden. Ein Tier verstarb noch vor Beginn der Operation während der Einleitung an einem massiven Herzinfarkt. Die durchschnittliche Gesamtoperationszeit betrug 270 min. Die Präparationszeit der infrarenalen Aorta bis zum Ausklemmen betrug im Mittel 45 min. Die durchschnittliche Abklemmzeit der Aorta betrug 75 min. Die mittlere iliakofemorale Abklemmzeit lag bei extraperitonealem Zugang für die linke Seite bei 45 min, für die rechte Seite bei 75 min. Nach erfolgreicher endoskopischer Bifurkationsprothesenimplantation erfolgte die Laparotomie und Resektion des aortobifemoralen Prothesensegments mit Originalstrombahn. Zur Überprüfung der Dichtigkeit wurden in vitro unter künstlicher Zirkulation eines Ringer-Laktat-Glyzerin-Gemisches die Leckage/min sowie der Berstungsdruck der endoskopisch genähten aortalen End-zu-Seit-Anastomosen untersucht und mit konventionell genähten End-zu-Seit-Anastomosen zwischen 6 h alten Schweineaorten und einer 6 mm im Durchmesser betragenden beschichteten Gelsoftprothese verglichen. Der maximale Berstungsdruck aller endoskopisch genähten Anastomosen lag bei 480 mmHg systemischem Mitteldruck, der niedrigste Berstungsdruck lag bei einem systemischen Mitteldruck von 140 mmHg. Minimal lag die Leckage/min bei systolischen Druckwerten von 120 −350 mmHg〈10 ml/min. Sämtliche endoskopisch genähten aortalen End-zu-Seit-Anastomosen waren in der Invitro-Dichtigkeitsprüfung hinsichtlich Berstung und Leckage/min durchaus mit den konventionell genähten Anastomosen vergleichbar.
    Notizen: Abstract The gasless videoendoscopic implantation of GELSOFT aortobifemoral vascular prostheses times 6×6 mm in diameter using an extraperitoneal approach was tested in ten porcine experimental models at the Surgical Department of the University of Cologne, Germany. Gasless videoendoscopic surgery is performed with a laparolift-laparofan system. Aortobifemoral GELSOFT prostheses were successfully implanted in nine of ten animals, whereby one animal died during preparations for surgery of massive coronary infarctions. Average surgical durations using the extraperitoneal approach were 270 min. Dissection of the infrarenal aorta until occlusion took 45 min, average aortic occlusion 75 min, and iliacofemoral occlusion 45 min for the left side and 75 min for the right side. After successful videoendoscopic implantation of aortobifemoral GELSOFT prostheses all nine animals underwent laparotomy and resection of the aortobifemoral prosthetic segment. The quality of the endoscopically sutured aortic end-to-side anastomoses was examined in vitro under artificial circulation of glycerol/Ringer's lactate solution for evaluation of possible leakage and bursting pressures and then compared to conventionally sutured end-to-side anastomoses of 6-h-old porcine abdominal aorta and GELSOFT prostheses 6 mm in diameter. The maximum bursting pressure of all endoscopically sutured anastomoses was 480 mmHg mean pressure; the minimum was 140 mmHg mean pressure. The minimum leakage per minute was less than 10 ml/min for systolic pressure values between 120 and 350 mmHg. All endoscopically sutured aortic end-to-side anastomoses were comparable to conventionally sutured anastomoses concerning in vitro evaluation of bursting pressure and leakage per minute.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...