Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 97 (1993), S. 4320-4325 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-1561
    Keywords: Furanocoumarins ; coumarins ; mass spectrometry ; leaf surface
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract Surface extracts of the leaves of five species in the Umbelliferae,Citrus limon (Rutaceae), andPsoralea bituminosa (Leguminosae) were examined for the presence of coumarins, after a previous study had shown the presence of three psoralens. In the current investigation eight more coumarins were identified by mass spectrometric techniques: the simple coumarins scopoletin, scoparone, and osthol, the linear furanocoumarins imperatorin and phellopterin, the angular furanocoumarins angelicin and pimpinellin, and the pyranocoumarin seselin. Five of these occur inApium graveolens, and scopoletin, scoparone, and imperatorin were each found in three of the species examined. The co-occurrence of all these coumarins on the surface may be significant in communication between the plant and its environment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Hyperfine interactions 81 (1993), S. 179-187 
    ISSN: 1572-9540
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract It has been demonstrated that the mass resolution of the quadrupole ion trap, or Paul trap, when operated as a mass spectrometer, may be varied over a wide range by reducing the mass scanning rate. Mass resolutions of 3.1×107 and 1.2×107 have been observed for ions ofm/z 414 andm/z 614, respectively, obtained from perfluorotributylamine, well in excess of the normal value of 3m, wherem is the ion mass. At the highest mass resolution observed, peak widths at half maximum are but 13.4×10−6 u.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simulation study is described of the behaviour of ions confined in a quadrupole ion trap during each of two separate operations of a tandem mass spectrometric experiment. The two operations are those of mass-selective ion isolation and mass-selective resonance excitation to the point of ion ejection from the ion trap. The method of mass-selective ion isolation simulated is that of consecutive ion isolation. Simulation data indicate that the collisional history of the ions prior to the isolation process can greatly influence the degree to which ions survive this process. Simulation data for mass-selective resonance ejection are compared with experimental data obtained with a Finnigan-MAT ion trap mass spectrometer. In each operation, the facility with which ions absorb energy from the field within the ion trap, whether this field is derived from the R.F. drive potential or a supplementary potential, can determine the extent to which ions are retained within the ion trap during the two mass-selective operations described.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 373-375 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A new geometric model has been developed and applied to the deconvolution of ion kinetic-energy release signals observed from fragmentation of metastable ions in the second field-free region of a reversed geometry mass spectrometer. The model takes account of: (i), fragmentations occurring throughout the entire length of the field-free region; (ii), the difference in ion beam intensity before and after the intermediate slit; (iii), the slight difference in angular acceptance between backward- and forward-scattered product ions; (iv), fragmentations of singly and multiply charged ions; and (v), ion kinetic-energy releases of any magnitude. Several examples of metastable peaks are given together with the associated kinetic-energy release distribution and the theoretical metastable peak generated from the kinetic-energy release distribution.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Commercial gas chromatography quadrupole ion-trap mass spectrometer (GC/ITMS) instruments have been used in a novel way for the study of negative ions formed from perfluorotributyl-amine and polychlorinated biphenyl compounds. Negative ions, formed during a normal electron impact ionization period in which 70 eV electrons were used, were isolated in an ion trap by the application of a negative DC voltage to the ring electrode that caused all positive ions to be ejected from the ion trap; in the subsequent analytical scan, negatives ions were detected with an electron multiplier biased normally so as to detect positive ions. The major negative-ion species detected from FC-43 were m/z 252 to m/z 633; 34 other negative-ion species were detected also, though in low abundance. The observed negative-ion mass range extended from m/z 252 to m/z 633. The signal-to-noise ratio of negative-ion mass spectra was enhanced by operation of the GC/MS instrument in GC mode and averaging the mass spectra acquired. In an examination of 3 hexachlorobiphenyl compounds, the molecular anion cluster around m/z 360 for the non-ortho-substituted congener 169 was observed with a signal-to-noise ratio of ca. 20 for 90 pg injected on column: the response for congener 169 was greater than that for congener 156 (mono-ortho-substituted) which, in turn, was greater than that for congener 153 (di-ortho-substituted).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 1 (1987), S. 132-135 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 929-934 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: When the working point of a precursor ion confined within a quadrupole ion trap is moved to the vicinity of a boundary of the stability diagram, fragmentation of the precursor ion can be induced by virtue of energy gained from the radio-frequency trapping field. This behaviour is known as the ‘border effect’. When the isolated precursor ion is subjected to a cooling period of variable duration, in the presence of helium buffer gas and prior to experiencing the ‘border effect’, a high degree of control of the fragmentation pattern is achieved. The cooling period causes decreases in both ion kinetic energy and ion axial excursions. From this preliminary study, it is suggested that the deposition of internal energy during the ‘border effect’ can be varied by changing the duration of the cooling period. In addition to a degree of control of internal energy deposition, the amount of energy which can be deposited in this manner, though unknown, appears to exceed those energy levels achievable with resonance excitation and the ‘border effect’ without collisional cooling, in that an additional fragmentation channel is accessed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 43-45 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The versatility of the quadrupole ion trap as a mass spectrometer in which the mass resolution may be varied over a wide range has been demonstrated. Mass resolution of 0.8 × 107 and 1.2 × 107 have been obtained for ions of m/z 414 and m/z 614, respectively, well in excess of the normal value of 3m, where m is the mass of ion. At the highest mass resolution, peak-widths at half-maximum are but 52 × 10-6 u. While it has been shown previously that enhanced mass reslution in the quadrupole ion trap can be achieved by reduction of the mass scanning rate, the range of mass resolutions reported here were achieved by reducing the mass scanning rate, in stages, by an overall factor of ca 5.5 × 104.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1076-5174
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A simple, inexpensive inlet system was developed for the introduction of liquid and solid samples, to be employed in commercial gas chromatographic/mass spectrometric instruments, and not requiring sample injection through the chromatographic column. The system does not need any modifications of the ion source housing and pumping system and is based on admitting the sample vapour as an underflow to the normal helium flow through the chromatographic column at a location near the transfer line.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...