Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1745-6584
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Geosciences
    Notes: Hydrographs of stream discharge were analyzed to determine ground-water recharge for two small basins draining into Mirror Lake, New Hampshire. Two methods of hydrograph analysis developed for determining ground-water recharge were evaluated, the instantaneous recharge method and the constant recharge method. For the instantaneous recharge method, recharge is assumed to be instantaneous and uniform over the basin. For the constant recharge method, recharge is assumed to be constant and uniform over the basin for a period of weeks to months. Both methods require that a ground-water recession slope be determined. The recession slope is used directly in the calculation for the instantaneous recharge method, and it is used as a base of reference for fitting a type curve in the constant recharge method. Results of the study indicated that the estimates of ground-water recharge for both methods agree to within about 10 percent. Two approaches to the instantaneous recharge method, manual and automated, were also evaluated, and the results were statistically similar.The baseflow component of streamflow commonly is assumed to be equivalent to ground-water recharge; therefore, two methods developed for determining the baseflow component of streamflow, graphical partitioning and digital filtering, were evaluated also. Baseflow values determined by graphical partitioning of hydrographs were about 25 percent less than the ground-water recharge values. Baseflow values determined by two different approaches to the mathematical digital filtering method were generally less than baseflow determined by graphical partitioning. However, one of the approaches to digital filtering agreed reasonably well with graphical partitioning if an appropriate filter constant was used. The other approach to digital filtering resulted in baseflow values that were much less than the other baseflow values and was therefore deemed inappropriate for use on these small mountain watersheds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...