ISSN:
0006-3592
Keywords:
Chemistry
;
Biochemistry and Biotechnology
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Biology
,
Process Engineering, Biotechnology, Nutrition Technology
Notes:
Volumetric mass-transfer coefficients were measured in an 11-L external-loop airlift fermenter with deionized water, a fermentation medium, and during a fermentation. Both a Mackareth oxygen electrode and a novel rapid-response probe were used. When the conventional step-change dynamic method was used for water, the long, nonlinear response time of the Mackareth electrode made correction of its readings difficult; this problem did not occur when the rapid-response probe was used. A comparison was made with a method of mass-transfer coefficient determination which does not involve any assumptions about the gas residence time distribution. However, this method requires that the liquid phase is well-mixed and this requirement was not met in the airlift fermenter. Comparison of the present results with other KL a determinations for airlift fermenters showed that KL a in water depends on the active gas holdup, the value of KL a/∊ at 20°C being ca. 0.37 s-1. Although higher gas holdups were obtained with the fermentation medium than for water, the values of KL a/∊ were lower, ca. 0.22 s-1 at 20°C.
Additional Material:
6 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/bit.260300207
Permalink