Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Berkeley, Calif. : Berkeley Electronic Press (now: De Gruyter)
    International journal of emerging electric power systems 5.2006, 1, art5 
    ISSN: 1553-779X
    Source: Berkeley Electronic Press Academic Journals
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: This paper introduces some field analyses of the wooden pole fire reports and online condition monitoring recorded data for line insulators of 33kV and 132kV overhead power lines of Petroleum Development Oman (PDO). From the statistical analysis of PDO pole fire reports, it was found that PDO southern directorates had higher number of pole fires during May-September 2004. Pole fires mostly occur for single poles of 33kV distribution lines close to graded roads, where the most common burning locations are at crossarm fixation and at ground foundation. Pollution monitoring systems provide very useful information which can be used to predict the pole fire events.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Berkeley, Calif. : Berkeley Electronic Press (now: De Gruyter)
    International journal of emerging electric power systems 7.2006, 3, art3 
    ISSN: 1553-779X
    Source: Berkeley Electronic Press Academic Journals
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Electrostatic and electrodynamic field analyses of 33kV line insulators were introduced to compare the electric-field and the current density profiles of commonly used line insulators in Oman; namely, silicone rubber (SiR) and porcelain line post insulators, and porcelain cap and pin insulator string. SLIM software package was used for such simulation, which is a fully integrated collection of software modules that provides facilities for the generation and solution of electromagnetic finite element models. The simulation results reveal that for the electrostatic simulation under pollution conditions, SiR and porcelain line-post insulators give maximum values of the electric field of 360kV/m and 1700kV/m, respectively. The latter value exceeds the recommended electric field level of 500kV/m. For the electrodynamic simulation under pollution conditions, the electric field and the current density are much higher for porcelain insulator compared to those of SiR insulator. The simulation of four cap-pin standard insulator string reveals that there is high electric field (1250kV/m) at the cap-insulator gap which can cause high current density for polluted case. Finally, the trend of the simulation results has been verified by experimental tests, which has been conducted on different 33kV line insulators having different designs and materials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗