Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 101 (1994), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Objective To examine the accuracy of sonographic determination of chorionicity in twin pregnancies at 10–14 weeks of gestation.Design Prospective study on the sonographic prediction of chorionicity at 10–14 weeks of gestation.Participants During a 30 month period, from October 1997 to May 2000, 165 women attending the departments of fetal medicine or ultrasound.Methods Sonographic criteria used in the diagnosis of chorionicity were the number of placental sites, the lambda (λ) and T signs and the thickness of the inter-twin membrane. The diagnosis of chorionicity was made at the time of the ultrasound examination using all these features and subsequently compared with the postnatal diagnosis, confirmed either by placental histology or discordancy in infant sex.Results In 150 cases with confirmation of chorionicity following delivery, 116 were postnatally classified as dichorionic and 34 monochorionic. Prenatal ultrasound examination correctly identified chorionicity in 149 (99.3%) cases. The most reliable indicator for dichorionicity was a combination using the λ sign or two separate placentae with a sensitivity and specificity of 97.4% and 100%, respectively. The most useful test in predicting monochorionicity was the T sign with a sensitivity of 100% and specificity of 98.2%. Measurement of the inter-twin membrane thickness was a less reliable indicator where the sensitivity for dichorionicity and specificity for monochorionicity was only 92.6%.Conclusions Ultrasound examination of twin pregnancies at 10–14 weeks of gestation predicts chorionicity with a high degree of accuracy using a combination of the number of placentae, λ and T signs and inter-twin membrane thickness. All hospitals should encourage departments providing ultrasound services to undertake chorionicity determination when examining women with twin pregnancies at this gestation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 103 (1996), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Objective To observe fetal arteriolar oxygen saturation during maternal epidural analgesia. Design An observation study of 27 epidural top-ups.Setting Labour ward, St James's University Hospital and Leeds General Infirmary, Leeds University, UK.Sample Seventeen fetuses in uncomplicated labour monitored with a N400 fetal pulse oximeter. Outcome measure A change in fetal pulse oximetry reading following epidural analgesia.Results There is no change in fetal oxygen saturation following an uncomplicated epidural top-up (F = 0.93; df 35 and 784).Conclusion An uneventful maternal epidural has no measurable effect on fetal oxygen saturation measured with a N400 pulse oximeter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...