Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of noninvasive electrocardiology 6 (2001), S. 0 
    ISSN: 1542-474X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: In most centers, exercise testing (ET) is performed by one or two trained technologists during the weekdays (0800 hours-1600 hours), leaving a void during evenings and weekends. This leads to unnecessary increased costs due to delays in management of patients. Electrocardiography technologists (ECGT) are often available for extended hours. This project was undertaken to improve the efficiency of the ET laboratory by using ECGT to perform ET during these extended hours.Methods: Clinical utility and cost saving of a 7 day per week ET for management of patients with suspected and/or known coronary artery disease utilizing ECGT was assessed after adequate training. Of 4099 patients undergoing ET between January 1995 and December 1997, 810 tests performed by ECGT were reviewed retrospectively.Results: Of the 810 patients (age mean 58.4 ± 0.44 yrs; range 16–88; males: 508, females: 302), 806 (99.5%) underwent the Bruce protocol. The indications were: diagnostic, 61.3%, predischarge acute myocardial infarction (AMI), 17.7%, evaluation of angina, 19.6%, other, 1.4%. Only 8 (0.1%) patients had complications (prolonged chest pain, 6; nonsustained ventricular tachycardia, 2) with no AMIs or deaths. This strategy resulted in a savings of 158 bed days (Can$189,600) on inpatients and 15 bed days (Can$18,000) on those presenting to the emergency department.Conclusions: This study demonstrates the feasibility and safety of utilizing ECGT for ET thus extending the hours of service. This resulted in efficient patient management, with a considerable cost-saving to the hospital. A.N.E. 2001;6(1):32–37
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Water, air & soil pollution 73 (1994), S. 1-9 
    ISSN: 1573-2932
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The intended rehabilitation of the site of a former coal gasification plant in Belfast provided an opportunity to analyse soil samples for a number of contaminants. Widely varying concentrations of cadmium, chromium, copper, lead, nickel and zinc as well as sulphate and cyanide anions were detected. A major contribution to soil contamination was the presence of complex mixtures of Polycyclic Aromatic Hydrocarbons also in highly variable concentrations. The random distribution of toxic contaminants both in area and depth indicates that a costly decontaminantion process will be required to make the site completely safe for reutilisation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...