Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 32 (2005), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary Currently CAD-CAM systems are rapidly gaining importance in dental practice as some of their products aim to combine aesthetics with strength and are free of metals. This study reports on the crown adaptation, marginal fit and clinical behaviour of 300 all-ceramic full coverage restorations (Procera®, Gothenburg, Sweden) placed in one clinical centre and followed up to 5 years. The marginal fit and coping adaptation before and after luting was determined by direct measurement as well as after sectioning in a laboratory study. Three hundred all-ceram restorations were installed in 165 patients between 1994 and 1998. Before the end of 2000, patients were recalled to assess their restorations, using the California Dental Association quality evaluation index, their own appreciation, as well as the reaction towards the periodontium. The in vitro data revealed a mean marginal adaptation of 30 μm, before and after luting of the Al203-coping onto the tooth. However, at the deepest part of the chamfer, the distance increased to 135 μm. In the clinical study only one restoration fractured, while in 6% small porcelain infractions occurred. After polishing the latter, no persistent patient complaints remained. At the last recall visit 1·8% of the margins were rated unacceptable. Dentists rated 72 and 78% of the restorations excellent for surface, colour and anatomic form respectively. Eighty-seven per cent of the patients rated their restorations more than 7/10 on an ordered analogue scale for aesthetics as well as for function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 31 (2004), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  Some previous studies suggest an association between tooth loss and hearing loss. The aim of this study is to assess the relation between oral status and hearing acuity. Forty-eight patients (mean age: 64·7 years) were allocated to four groups: one was wearing complete dentures in both jaws, another had shortened dental arches, a third had full dental arches in both jaws and the last lacked any occlusal stops (i.e. no occlusal vertical dimension, because of the absence of teeth or occlusal pairs). Audiological testing was performed in a noise-free chamber. Air and bone conduction were checked at different frequencies and the air-bone gap was determined. After correction for age and gender, a difference in air and bone conduction because of the oral status was found for low and for high frequencies while no significant differences were (P 〈 0·05) found for the air-bone gap. The number of teeth, number of occluding tooth pairs and presence or lack of occlusal vertical dimension, was significantly related to the gradient of hearing loss (P 〈 0·05). The discrepancy in hearing loss between complete denture wearers and patients without any occlusal vertical dimension, strengthens the hypothesis that it is the lack of the latter that is associated with hearing loss. At what level hearing loss occurs, needs further investigation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Prosthetic outcome and patient satisfaction were evaluated in order to investigate whether there is a need or advantage to splint two implants in the mandible retaining a hinging overdenture. This study included 36 fully edentulous patients randomly divided into three groups according to the attachment system they received: magnets, ball attachments or straight bars (reference group). None of the implants failed during the whole observation period in any of the groups. After 5 years of observation, the Bar group presented the highest retention capacity and the least prosthetic complications but revealed more mucositis and gingival hyperplasia. Patient satisfaction rated similar for all groups although the Magnet group showed lower retention forces. All patients would repeat the same treatment even though the majority of the Magnet group would prefer a more retentive solution because of limited denture stability.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The fit of implant supported fixed prostheses is said to be of clinical concern because of the rigid fixation of an oral implant in its surrounding bone. The influence of the torque sequence of the set screws during fixation of implant supported fixed full prostheses on the final pre-load was investigated in vitro. No significant effect of the torque sequence of the set screws on the final pre-load was observed. The main objective of this study was to quantify and qualify the pre-load in vivo on implants supporting a fixed full prosthesis. This was performed when the prostheses were supported by all five or six implants and was repeated when the prostheses were supported by only four and three implants. A total of 13 patients with a fixed full implant supported prosthesis were selected. The existing abutments were changed for strain gauged abutments. After tightening the set screws with a torque of 10 N cm, the pre-load conditions were registered. The average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 323 N (43 N), 346 N (59 N), 307 N (60 N) 21 N cm (3 N cm) and 21 N cm (2 N cm), 23 N cm (5 N cm), respectively. In addition, the pre-load was registered after fixation of a machined gold cylinder, as delivered by the manufacturer, on each of the supporting implants, representing the ‘optimal fit’ situation. The corresponding average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 426 N (36 N), 405 N (40 N), 413 N (46 N) and 8 N cm (1 N cm), 8 N cm (1 N cm), 8 N cm (1 N cm), respectively. The induced axial forces after tightening the prostheses were significantly lower then after tightening the gold cylinder in case of five or six supporting implants (P 〈 0·02). The induced bending moments after tightening the prostheses were statistically significantly higher (P 〈 0·0001) then after tightening the gold cylinder in all test conditions (five or six, four or three supporting implants). This study underlines the static load present after screw tightening implant supported fixed full prostheses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This paper describes a methodology that allows in vitro and in vivo quantification and qualification of forces on oral implants. Strain gauges are adapted to the outer surface of 5·5 and 7 mm standard abutments (Brånemark System®, Nobel Biocare, Sweden). The readings of the strain gauges are transformed into a numerical representation of the normal force and the bending moment around the X- and Y-axis. The hardware and the software of the 3D measuring device based on the strain gauge technology is explained and its accuracy and reliability tested. The accuracy level for axial forces and bending moments is 9.72 N and 2.5 N·cm, respectively, based on the current techniques for strain gauged abutments. As an example, an in vivo force analysis was performed in a patient with a full fixed prosthesis in the mandible. Since axial loads of 450 N and bending moments of 70 N·cm were recorded, it was concluded that the accuracy of the device falls well within the scope of our needs. Nevertheless, more in vivo research is needed before well defined conclusions can be drawn and strategies developed to improve the biomechanics of oral implants.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 6 (1995), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The Periotest® device was used to evaluate the damping characteristics of different bone-to-implant interfaces of Brånemark implants. Implant and abutment lengths were found to have a significant influence on Periotest value (PTV). There was no statistical difference between PTVs of implants located in the anterior and posterior areas of the same jaw at abutment connection. No differences were found between PTVs of standard and self-tapping implants. PTVs at abutment connection were highly influenced by the bone quality. The contact with two corticals, one at each extremity of the implant, was of a greater influence in the maxillary than in the mandibular jaw, indicating a firmer anchorage between the bicortical implants and the surrounding bone. A proaressive decrease of PTVs over time was observed, significant up to 5 years of loading.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 3 (1992), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: For several years, osseointegrated implant-supported overdentures have been used in the rehabilitation of full edentulism with excellent results, at least in the lower jaw. This study involved 3 groups of patients with different prosthetic reconstructions:(1) mandibular overdentures supported by 2 implants connected by a bar (30 patients), (2) mandibular fixed prostheses supported by 4–6 implants (25 patients) and (3) mandibular complete dentures without implant support as controls (85 patients). The primary aim of this study was to examine on orthopantomograms (by means of the area index to minimize distortion and magnification errors), posterior mandibular ridge resorption in the 3 treatment groups. The present data demonstrated a minimal posterior mandibular ridge resorption in patients with fixed implant-supported prostheses. A more considerableposterior ridge resorption was observed in the complete denture group and especially in the overdenture wearers. For the latter, the annual posterior jaw bone resorption after the post-extraction remodeling period of 6 months, was 2- to 3-fold that of full denture wearers. When patients were edentulous for more than 10 years, the difference between the 2 latter groups disappeared. It is suggested that although the overdenture design on 2 implants offers advantages from a financial and failure rate point of view, its indications in younger patients should cautiously be evaluated in a long-term perspective concerning posterior mandibular bone resorption.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 3 (1992), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: It has been documented that the long-term clinical outcome of the Brånemark® system is very favourable. However, failures do occur before and after loading. This study examined the differences in marginal bone loss between standard and self-tapping fixtures and attempted to explain excessive marginal bone loss or loss of osseointegration during the first 3 years of loading. Marginal bone loss (scored on long cone radiographs) and fixture failure rate were compared for different fixture designs. For standard fixtures, in comparison with self-tapping fixtures, the failure rate was clearly higher before as well as after loading. However, for successful fixtures no difference in marginal bone loss was observed. For the conical fixtures an increased marginal bone loss around the smooth part was observed. The effect of fixture overload, marginal bone height and loss of osseointegration was examined in 69 patients with 1 and 15 patients with 2 fixed full prostheses, and in 9 patients with an overdenture in the upper jaw. Excessive marginal bone loss (more than 1 mm) after the first year of loading and/or fixture loss correlated well with the presence of overload due to a lack of anterior contact. the presence of parafunctional activity and osseointegrated full fixed prostheses in both jaws.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 12 (2001), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: In the present study, speech function was assessed in edentulous patients wearing fixed or removable dental prostheses supported or not by oral implants. A total of 138 patients participated in the present research. The experimental group (n=113) was divided in 4 subgroups. Subgroup FD/FFPi comprised 22 patients with a maxillary full denture (=FD) and a mandibular fixed full prosthesis on implants (=FFPi). Subgroup FFPi/ND consisted of 27 patients with a maxillary fixed full prosthesis on implants and a natural dentition (=ND) in the mandible. Subgroup FD/ODi included 49 patients wearing a maxillary full denture and a mandibular overdenture on 2 implants (=ODi). Subgroup FFPi/FFPi comprised 15 patients having a fixed full prosthesis on implants in both jaws. The outcome of the logopedic screening of the experimental group was compared with that of a control group of subjects having a natural dentition (ND/ND; n=25). A standard clinical procedure for evaluation of speech was carried out by a speech pathologist. Besides, specific oral and prosthetic parameters were scored in all patients. It was established that one or more pronunciation difficulties occurred in 84% of the patients of the experimental group. This was significantly more than in the control group, where half the number of subjects had some speech deficiencies. No clear influence of specific oral and prosthetic parameters could be identified. From the present results, it could be concluded that in patients rehabilitated with oral implant-supported prostheses speech disorder is more frequently observed than in subjects with a natural dentition.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of clinical periodontology 18 (1991), S. 0 
    ISSN: 1600-051X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract. So far, preprosthetic surgery for oral defects improved prosthetic retention problems for only a limited amount of time and led to many side-effects. The alternative offered by the osseointegration technique developed by P.–I. Brånemark changed the concept of preprosthetic surgery dramatically. By means of a few permucosal titanium screws, bridges or overdentures can be retained even in cases of advanced jaw bone resorption. When the latter is extreme, an autologous free bone graft fixed by means of self-tapping titanium implants can offer the necessary support for sometimes elaborate prosthetic reconstructions. The marginal bone loss around Brånemark implants is very limited after a 1st year of bone remodelling, even when an autologous transplant has been used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...