Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1600-0714
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Fifty-two cases of non-Hodgkin's lymphoma (ahl) In The oral and maxillofacial region, comprising 31 submucosal (extra-nodal) and 21 cervical node Nhls, Were investigated. The patients' ages ranged from 5 to 86 years, with a bimodal age distribution among young people below 12 years of age (average 8 years) and in those aged 30 years or older (average 60.3 years). The male-to-female gender difference ratio was 1.3:1. Patients presented with swelling as the major symptom. Histologically. diffuse, large cell malignant lymphoma was the most frequent type and 67.9″.!’of lymphomas were of intermediate malignancy as defined by the Working Formulation for Clinical Usage. All submucosal lymphomas showed diffuse proliferation patterns, although follicular proliferation was identified in 5 of the 21 nodal lymphomas. Immunohislochemistry showed that the B-cell type was predominant, especially in nodal lymphomas.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 29 (2002), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The design of removable partial dentures (RPDs) is an important factor for good prognostications. The purpose of this study was to clarify the effectiveness of denture designs and to clarify the component that had high rates of failure and complications. A total of 91 RPDs, worn by 65 patients for 2–10 years, were assessed. Removable partial dentures were classified into four groups: telescopic dentures (TDs), ordinary clasp dentures (ODs), modified clasp dentures (MDs) and combination dentures (CDs). The failure rates of abutment teeth were the highest and those of retainers were the second highest. The failure rates of connectors were generally low, but they increased suddenly after 6 years. Complication and failure rates of denture bases and artificial teeth were generally low. Complication and failure rates of TDs were high at abutment teeth and low level at retainers. Complication and failure rates of ODs were high at retainers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Purpose: For a complete denture to function effectively, the denture must be stabilized during mastication. The alveolar ridge has various forms, and we must choose the artificial tooth arrangement that is most suitable to the form of the alveolar ridge. The purpose of this study was twofold: (i) to examine the relationship between the alveolar ridge form and the stress distribution on the mucosa, and (ii) to model the contact condition between the denture base surface and mucosa. Materials and methods: In this study, the three-dimensional finite element method was used for the analysis. Four types of alveolar ridge were prepared. As a loading condition, three load places were prepared: the mesial position, the central position and the distal position. We utilized the ‘contact option (MARC)’ to simulate the true behaviour of the denture. Results: We were able to model the contact condition by using the ‘contact option’. Maximum stresses were distributed on the alveolar ridge in which the absorption is severe. And, the distal load produced large compressive stresses on the inclined plane of posterior alveolar ridge in which alveolar form.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 30 (2003), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  Five types of removable partial dentures (two attachment dentures, two telescopic dentures and one clasp denture) were designed. The two attachment dentures were retained by the rigid-precision attachments with or without a stabilizing arm, and the two telescope dentures were retained with cone telescope crowns with or without cross-arch stabilization. The stresses acting on abutment teeth and denture bases and the movements of denture bases were investigated, and the influences of denture design were clarified. The stress acting on a terminal abutment tooth retained by a rigid-precision attachment or cone telescopic crown was larger than that acting on a terminal abutment tooth retained by a clasp. The attachment dentures tended to concentrate more stress at the terminal abutment tooth than did the telescopic dentures. The stress of denture base of an attachment denture and a telescopic denture was less than that of a clasp denture. There was no difference between the stresses of attachment and telescopic dentures. The displacement of the denture base tended to be less when the denture was designed with a rigid connection for the retainer and with cross-arch stabilization.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...