Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 3345-3346 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The Synchrotron Ultraviolet Radiation Facility (SURF II) at the National Institute of Standards and Technology, Gaithersburg, MD, USA, has served as a primary radiometric standard in the vacuum ultraviolet region since its conversion from a synchrotron to an electron storage ring in 1974. The magnet iron, however, dates back to an original betatron design of the late 1940s. The advent of both modern materials and methods of finite element analysis have made possible the design of magnets offering far greater dc performance than the existing SURF system. In this paper we discuss the general design and plans to convert SURF II to SURF III, which will offer reduced radiometric uncertainty, an increase in energy from 300 MeV to 385 MeV, a modernized control system, and two new beamlines, which are not presently possible. Anticipated new beamline activities include a substantial new effort devoted to radiometric improvements from IR to far UV and development of stations for microspectoscopy and electroreflectance. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 59 (1991), S. 2947-2949 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The density of ground-state mercury ions in the cathode region of a fluorescent-lamp-like discharge is measured using laser-induced fluorescence (LIF) at 194.2 nm. LIF is used to make relative density measurements with good spatial resolution and a wide dynamic range while a previously reported absorption technique is used to provide the absolute normalization for these maps.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...