    Journal of cardiac surgery 15 (2000), S. 0 
    ISSN: 1540-8191
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract Objectives: The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Material and Methods: Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. Results: The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as “solo surgery.” Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 Å 34 and 50 Å 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Conclusion: Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiac surgery 17 (2001), S. 0 
    ISSN: 1540-8191
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract  Objectives Redo mitral valve surgery via sternotomy is associated with a substantial morbidity and mortality. This study evaluated a minimally invasive technique for mitral valve redo procedures. Material and Methods: Out of a series of 394 patients undergoing mitral valve repair or replacement via a right minithoracotomy, 39 patients underwent redo mitral valve surgery (59 ± 13 years, 23 female). Previous cardiac surgeries included 17 patients with mitral valve repair, 6 patients with mitral valve replacement, 3 patients with aortic valve replacement, 2 patients with atrial septal defect closure, and 11 patients with coronary artery bypass grafting (CABG). In all cases, femoro-femoral cannulation was performed. The port access technique was applied in patients undergoing redo valve surgery. In patients with prior CABG, the operation was performed using deep hypothermia and ventricular fibrillation. Results: In all cases, sternotomy was avoided. The mitral valve was replaced in 20 patients and repaired in 19. Time of surgery and cross-clamp time were comparable with the overall series (168 ± 73 [redo] vs 168 ± 58 min and 52 ± 21 [redo] vs 58 ± 25 min). Mortality was 5.1%. One patient had transient hemiplegia due to the migration of the endoclamp. All other patients had uneventful outcomes and normal mitral valve function at 3-month's follow-up. Conclusion: Redo mitral valve surgery can be performed safely using a minimally invasive approach in patients with a previous sternotomy. The right lateral minithoracotomy offers excellent exposure. It minimizes the need for cardiac dissection, and thus, the risk for injury. Avoiding a resternotomy increases patient comfort of redo mitral valve surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...