Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-904X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-904X
    Keywords: bioequivalence ; truncated area ; clearance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Purpose. To compare the applicability and accuracy of truncated area (AUCt; where t represents truncated time) versus area to the last quantifiable time point [AUC(O-T)] for assessing bioequivalence. Drugs with either very low or very high intra-subject variability in clearance (CL) were selected for study. Clearance variability was defined by the number of subjects with a quantifiable plasma value (Cp) at each collection time from 24 hrs to last collection time (T). Methods. Data for amiodarone and danazol, drugs with different distributions of subject CL were examined. For amiodarone, the number of subject samples observed (test + reference) at the time of the last quantifiable concentrations was 60 at 240 hrs(T), 16 at 144 hrs and 4 at 96 hrs; while danazol had 4 at 96 hr(T), 3 at 72 hrs, 16 at 60 hrs, 7 at 48 hrs, 14 at 36 hrs, 11 at 24 hrs, 13 and 2 at 16 and 12 hrs, respectively. Simulations (Scenarios A and B) were performed to obtain populations (N = 24) with CL patterns similar to those of amiodarone and danazol. For scenario A (CL pattern similar to amiodarone), log-normally distributed CL values (28.8 L/HR) with intra-subject coefficient of variation (CV) of 25%, 40% and 60% gave the desired CL pattern. Scenario B (CL pattern similar to danazol) required that a subpopulation with an increase in CL of 40% from baseline (i.e., 40.32 L/HR) in 5%, 10% and 20% of the population represent the desired distribution. Power was evaluated by the percentage of times the simulated trials were declared bioequivalent (i.e., the number of times the test vs. reference 90% CI was within 80−125%), while accuracy was determined when the true difference in fraction absorbed (i.e., 1.25) was within the CI. Each simulation was repeated 300 times. Results. The simulation results for Scenario A indicated that the statistical results using truncated area (AUCt) had power and accuracy equivalent to that obtained using the AUC(O-T) metric. However, results for Scenario B indicated that AUCt had less power and accuracy than that obtained using AUC(O-T). The confidence interval (CI) for amiodarone was the same whether AUC (0-T) or AUCt was used as the metric for extent, while for danazol, the AUC(O-T) and AUCt differed in the lower limit by 7%. Conclusions. The truncated area, AUCt, has the greatest power and accuracy when the population clearance is such that most subjects have measurable plasma concentrations at last collection time(T), resulting in a proportional loss of data from each subject.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...