Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Allergy 58 (2003), S. 0 
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background:  Several studies have attempted to assess nasal nitric oxide (NO) levels in allergic rhinitis (AR). However, there seem to be differences in the results obtained. We therefore wanted to investigate this further by studying airway NO in AR and controls at several modalities, and also the effect of intranasal administration of the nitric oxide synthase (NOS) inhibitorNG-nitro-l-arginine-methyl ester·HCl (l-NAME).Methods:  Airway NO was determined through repeated measurements at three flow rates of air (0.5, 3, and 9 l/min), using a single-breath method and a method of nasal aspiration, in 18 patients with birch pollen AR during season and in 18 controls.Results:  Patients with AR were characterized by no difference in nasal but higher orally exhaled NO and a larger interindividual spread in nasal and orally exhaled NO compared to controls. We also found a greater reduction in nasal NO after l-NAME in patients compared to controls.Discussion:  These results indicate that several factors determine the levels of nasal NO in rhinitis. NO production in the nasal mucosa of patients with AR may be upregulated. On the other hand, this increase could be counteracted by swelling of the mucosa and secretions resulting in impaired NO diffusion from, for example, the paranasal sinuses, where particularly high levels of NO have been found. Also, the high background levels of NO from constitutive sources in the nose may blunt smaller increases in mucosal NO output.Conclusion:  It seems that the methods for measurement of nasal NO need to be improved and standardized before we can consider to use this test in monitoring inflammation in AR.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Flow, turbulence and combustion 3 (1954), S. 409-416 
    ISSN: 1573-1987
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Summary Two manometers for dynamical measurements (up to frequencies of the order of 50 Hz) are described which were developed for measuring blood pressure in cardiac catheterization studies and for measurements in pneumatic controllers respectively. The principle of a differential transformer was used in which the core was entirely borne by a phosphorbronze membrane. The diameter of the blood pressure manometer is 2 mm (fitting to no. 6 catheter), its length 10 mm. The most important properties of the manometers are to be found in § 4.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...