Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 46 (1991), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A fatal case of theophylline poisoning is described. The patient developed rhabdomyolysis, renal failure and compartment syndrome, as well as the more usual features of severe theophylline poisoning. Dantrolene appeared to be useful in controlling the hypermetabolic state associated with the overdose and may have a role in future treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford : Blackwell Science Ltd
    Anaesthesia 53 (1998), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A multicentre trial of the use of the intubating laryngeal mask was carried out at seven centres in the United Kingdom using the same agreed protocol. Lung ventilation followed by blind tracheal intubation through the intubating laryngeal mask was attempted on 500 ASA grade 1 and 2 patients. It was possible to insert the intubating laryngeal mask in all 500 cases. Ventilation via the intubating laryngeal mask was described as satisfactory in 475 (95%) cases, difficult in 20 (4%) cases and unsatisfactory in 5 (1%) cases. Blind tracheal intubation through the intubating laryngeal mask was possible in 481 (96.2%) cases within three attempts. Intubation was successful at the first attempt in 399 (79.8%) cases, at the second attempt in 62 (12.4%) cases and at the third attempt in 20 (4%) cases. The tracheas of 19 (3.8%) patients were not successfully intubated within the three attempts. Ventilation via the intubating laryngeal mask was described as unsatisfactory during two of these cases but oxygenation remained satisfactory in spite of this. Seventeen of the 19 failures occurred during the individual operator's first 20 attempts. The intubating laryngeal mask provides a successful method for blind tracheal intubation in a large proportion of cases and appears to be superior to the standard laryngeal mask airway for this purpose. The intubating laryngeal mask may be of use when tracheal intubation has failed using conventional methods.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford : Blackwell Science Ltd
    Anaesthesia 54 (1999), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The incidence and origin of contamination of the vocal cords in 53 trauma patients was studied when tracheal intubation was performed before hospital admission. Eighteen patients (34%) had gross contamination which was blood in 15 patients and gastric contents in three patients. This has implications for prehospital airway management and particularly for use of the laryngeal mask airway.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford : Blackwell Science Ltd, UK
    Anaesthesia 53 (1998), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The use of the intubating laryngeal mask in three patients is described. In two patients for whom tracheal intubation using traditional techniques had failed, the intubating laryngeal mask was used to achieve successful tracheal intubation. The trachea of one of these patients was subsequently re-intubated for a second procedure using the same technique. A third patient with a cervical spine fracture whose trachea was electively intubated using the intubating laryngeal mask is also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 49 (1994), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A retrospective study of admissions to a Level 1 Trauma Centre, revealed 393 patients with traumatic cervical spine injuries. All 36 patients intubated urgently and 37 and 68 patients intubated between 30min and 24 h of admission, were intubated orally, following a rapid sequence induction with the application of cricoid pressure and manual in-line stabilisation of the head and neck. There were no neurological sequelae in these 73 patients (95% confidence interval 0–4%). This technique for airway management is described in detail. It is a safe, familiar, and effective method for securing the airway in patients with cervical spine injury.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 47 (1992), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A randomised, single-blinded study was conducted to compare patient-controlled epidural analgesia with continuous infusion epidural analgesia for the treatment of pain following post-traumatic pelvic reconstruction. The patient-controlled group (n = 11) received a background infusion of 4 ml.h−1 of bupivacaine 0.125% with fentanyl 1 μg.ml−1, and 3–6 ml bolus doses, self administered, as required (with a 15 min lockout interval). The continuous infusion group (n = 12) received a continuous infusion of the same solution through an identical apparatus, but with the demand button deactivated. This was started at 10 ml.h−1 and adjusted by the anaesthetist, as required, up to a maximum of 25 ml.h−1. Pain scores, side effects, and the volumes of drug infused were recorded over the first 3 postoperative days. One patient from each group was withdrawn because of catheter-related problems. Pain scores were similar and the incidence of nausea and pruritus was low in both groups. There was no recorded instance of respiratory depression or hypotension and there was no significant difference between the groups in the volumes of drug solution received. Patient satisfaction was equally very good in both groups. Patient-controlled epidural analgesia is an effective means of providing pain relief after post-traumatic pelvic reconstruction, but did not significantly reduce analgesic requirements in comparison with continuous infusion epidural analgesia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 198 (1963), S. 104-105 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] On removal of the median ventral portion of the pectoral girdle it was immediately obvious that the specimen possessed a single anterior vena cava ; the blood from the anterior left side drained into the right vena cava via a large transverse vein anterior to the heart and the right external ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Cellular and molecular life sciences 34 (1978), S. 1152-1154 
    ISSN: 1420-9071
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Differences in the sounds of 4 species of tsetse flies have been demonstrated. It has also been shown that tsetse flies perceive and react to sounds made by other members of the species.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 221 (1969), S. 491-492 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Twenty Patella vulgata L., distributed throughout the tidal range, were selected for the experiment, which was carried out on Black Rock on Dale beach. Ballantine2 rated the shore as "very sheltered". The experiment began on July 3, 1968, and continued until July 8. The limpets' shells and the ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 16 (1990), S. 394-398 
    ISSN: 1432-1238
    Keywords: Theophylline ; Poisoning ; Treatment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Sixty-four cases of theophylline poisoning were reviewed. All but two cases represented intentional self poisoning. The majority of patients were young females who presented acutely after ingestion of sustained release preparations prescribed for asthma. Serum theophylline levels (mean 365 μmol/l, SD 177) indicated a high risk of toxicity. Electrolyte and metabolic abnormalities (hypokalaemia, hypomagnesaemia, hypophosphataemia, hyperglycaemia, acid-base disturbances and leucocytosis) were common. Serum potassium, serum glucose, leucocyte count and length of stay in the intensive care unit all correlated strongly with maximum serum theophylline level (p〈0.001). The low incidence of life-threatening manifestations of severe toxicity (hypotension, serious arrhythmias or seizures) and excellent outcome, contrasts with many previous reports. The results support the use of a management regimen which emphasizes intensive supportive therapy and restricts the use of charcoal haemoperfusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...