Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Steroid Biochemistry 20 (1984), S. 1492 
    ISSN: 0022-4731
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Clinica Chimica Acta 64 (1975), S. 1-9 
    ISSN: 0009-8981
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Bioluminescence and Chemiluminescence 4 (1989), S. 185-190 
    ISSN: 0884-3996
    Keywords: Luminescence immunoassay ; thyrotropin ; coated tube ; monoclonal antibody ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A recently available chemiluminescence immunoassay (LIA-MAT) for TSH, set up by Byk-Sangtec Diagnostica, has been evaluated and compared with IRMA methods. The system LIA-MAT uses two monoclonal antibodies: one coated on tubes and the other labelled with isoluminol. To compute the within-assay precision profile, we estimated the response error relationship from all the duplicates (420) of eleven experiments. The CV of the response was 4-5% from the maximal response until 10,000 RLU (corresponding to about 1 μlU/ml); in the lower response range the CV worsened up to 8%. The sensitivity, derived from the precision profile, was 0.052 μlU/ml similar to that found in IRMA-MAT (0.044 μlU/ml); the working range extended from 0.33 to 100 μlU/ml. Results from LIA-MAT in the concentration range 1-30 μlU/ml were compared with the consensus mean produced by users of IRMA methods (IRMA-MAT, IRMA-Behring, Maiaclone Serono) participating in an inter-laboratory survey; a good correlation with IRMA techniques was found. The distribution of TSH determinations produced by LIA-MAT on 62 low concentration sample (〈0.3 μlU/ml) from patients unresponsive to TRH test, was found similar to that observed for the kit IRMA Boots-Celltech assumed as reference.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Bioluminescence and Chemiluminescence 4 (1989), S. 620-626 
    ISSN: 0884-3996
    Keywords: Immunochemiluminometric assay ; thyrotropin ; monoclonal antibody ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: A recently available immunochemiluminometric assay (ICMA) for TSH developed by Ciba Corning Corp. has been evaluated. This system (Magic Lite) uses an acridinium-ester-labelled antibody and magnetizable particle for bound-free separation. In each assay only two calibrators are carried out and used to re-scale a manufacturer-generated curve stored in the memory of the luminometer. The precision of the response (RLU) estimated by all duplicates of 14 runs was about 4% for responses 〉12,000 RLU (corresponding to a concentration interval 0.7-113 μlU/ml) and worsened in the lower range (up to 10% CV); the sensitivity, computed from the mean within-assay precision profile, was 0.028 μlU/ml; the between-assay precision ranged from 4.6 to 13.1 CV%. Regression analysis of ICMA results (y) against consensus values of Behring IRMA (x) on 15 QC sera assayed in an inter-laboratory survey (concentration range 1-30 μlU/ml) gave y = -0.003 + 0.98x indicating a good agreement of the two techniques. Similar conclusions have been derived from the comparison of the ICMA results (y) in the low TSH concentration range (〈 1 μlU/ml) against the IRMA Boots Celltech (x) on 80 patient samples (y = 0.04 + 1.04x).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...