    s.l. : American Chemical Society
    Analytical chemistry 65 (1993), S. 3378-3381 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 6 (1995), S. 249-258 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ions released from implant surfaces are suspected of playing some role in osteolysis surrounding metal prostheses. To understand how ions may affect osteogenesis, previous work exposed osteogenic cells to metal ions to study acute cytotoxic responses. The purpose of this study was to assess the long-term effects of sublethal ion concentrations on osteogenic cell proliferation and function. Bone marrow stromal cells were harvested from juvenile rats and exposed to solutions of ions associated with Co-Cr-Mo and Ti-6Al-4V implants. Cells were cultured for up to 4 weeks and assayed for total protein, alkaline phosphatase, osteocalcin, and calcium. Other than V+5, none of the ions affected cell proliferation, indicating that the chosen concentrations were sublethal as desired. V+5 elicited delayed gross toxicity not previously observed during acute experiments. At the chosen concentrations, Co+2, Cr+6, Mo+6, and Co-Cr-Mo alloy elicited little effect on cell proliferation and moderate effects on matrix mineralization. Cultures exposed to Ti+4, Al+3, and Ti-6Al-4V alloy also showed no decrease in cell number, but did show near total suppression of osteocalcin secretion and matrix mineralization. These results suggest that ions released from Ti alloy implants may interfere with osteoblastic cell differentiation, contributing to periprosthetic osteolysis by impairing normal osteogenesis. © 1995 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 6 (1995), S. 109-116 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effects of metal ions released from orthopedic implants on nearby bone cells remain largely unknown. The purpose of this study was to examine the acute toxicity of metal ions on osteogenic cells derived from bone marrow. Bone marrow stromalcells were cultured with metal ions found in commonly used orthopedic implants, that is, Ti-6Al-4V, Co-Cr-Mo, and 316L stainless steel. Solutions of individual ions and combinations representing the alloy composition were prepared from atomic absorption standards and added to the cultures to give concentrations ranging from 50 ppb to 5o ppm. After a 48-h period of exposure to ions, the bone marrow cultures were examined for effects of cytotoxicity by measuring total cell number, total cell protein, and mitochondrial activity. Cr6+ was grossly cytotoxic; Co2+, Mo6+, Fe3+, and Ni2+ were moderately cytotoxic; and Ti4+, Al3+, V5+, and Mn2+ were minimally toxic, as determined by the assays used. Ion solutions representing Co-Cr-Mo and 316L stainless steel were moderately toxic; solutions representing Ti-6Al-4V were toxic at only the highest concentrations used. The observed cytotoxicity was time-dependent, with irreversible toxic effects being initiated following as short as a 3- to 6-hour exposure. These results show that metal ions associated with Co-Cr-Mo and 316L stainless steel are toxic to osteogenic cells at concentrations approximating those measured in the fibrous membrane encapsulating orthopedic implants. © 1995 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 711-723 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Responses of neonatal rat calvarial osteoblasts to a variety of orthopedic implant materials were examined in vitro. Attachment, proliferation, and collagen synthesis of a well-characterized line of osteoblasts with 316L stainless steel, Ti-6Al-4V, CoCR-Mo, PMMA, hydroxyapatite, borosilicate glass, and tissue culture polystyrene were studied. Cell adhesion and growth were similar on nonapatitic materials. In contrast, attachment and growth of osteoblasts were significantly lower and slower, respectively, on hydroxyapatite. Collagen synthesis per cell and relative collagen synthesis, however, were comparable on all the materials tested.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...