    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Fatigue & fracture of engineering materials & structures 20 (1997), S. 0 
    ISSN: 1460-2695
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract— Continuous low cycle fatigue (LCF) tests with-and without-hold time in push-pull and torsion loading modes and sequential LCF tests in push-pull mode were carried out at 650°C in air on thin tubular specimens of 316 stainless steel; the sequential tests involving pure fatigue (PF) and creep-fatigue (CF) loadings. The growth of short fatigue cracks was studied by taking several replicas from the specimen surface which were subsequently observed under a scanning electron microscope. An analysis was done with respect to both crack density and the orientation of microcracks and macrocrack(s) which led to failure.Crack density was higher on the surface of a CF tested specimen than that of a PF tested specimen. Mainly short cracks oriented at 45° to the specimen axis were observed on a torsion fatigue tested specimen surface. For push-pull specimens the microcracks propagated perpendicular to the specimen axis to form macrocracks that propagated in the same direction. On the other hand, for torsion specimens the microcracks which initially propagated at 45° to the specimen axis linked to form macrocracks oriented parallel and perpendicular to the specimen axis. However, the macrocrack responsible for the final fracture was always oriented parallel to the specimen axis.Cumulative damage was dependent on the type of loading (PF or CF) in the first part of sequential tests. In particular microcracks initiated during an initial damage phase observed under sequential LCF tests in PF were found to be healed by oxide formation during the hold times applied in the subsequent CF loading and this produced a total damage summation significantly larger than one.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...