Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 144 (1990), S. 79-87 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Rat luteinizing hormone /LH/ was labelled with125I by the Chloramine T method.125I-LH, used as tracer in radioimmunoassay, was separated from the labelling reaction mixture by gel filtration. By using the proper protein/radioiodine ratio in the labelling reaction mixture the specific activity of125I-LH was adjusted to 2.5–20.5 MBq μg−1. The influence of the specific activity on the assay parameters as well as on the tracer stability was investigated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 181 (1994), S. 263-279 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract A method has been developed enabling the direct coupling of first or second antibody to finely dispersed magnetite (Fe3O4). The immunosorbent thus produced was applied in various radioimmunoassay systems (T3, T4, TSH, Cortisol) for the separation of bound and free antigens. The elimination of the need for “precoating” the magnetic particles with a polymer has several advantages. One of them lies in the ease of one-step production of the immunosorbent and other is the high antibody/magnetite ratio. The influence of the concentration of the immunosorbent and detergent (TWEEN 20 or TRITON X-100) on the assay parameters (Bo, NSB, etc.) has been systematically investigated and the optimum concentration of the magnetizable particles and detergent has been determined. The reliability of magnetic separation has been validated by comparing it with the conventional PEG separation method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...