    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background and Aim: There is an increasing use of active-fixation leads for cardiac pacing, yet concerns remain regarding initial high stimulation thresholds. The aim was to perform a detailed analysis of pacing parameters at the time of implantation to determine when lead repositioning should be considered. Methods: We performed a prospective observational study of consecutive new pacemaker implants. Detailed analysis of pacing parameters was collected at 2-minute intervals for 10 minutes, and at day 1 and week 8 following implant. Results: Ninety-four patients underwent implantation of 79 dual-chamber and 15 single-chamber pacemakers using active-fixation leads in both chambers. An initial threshold of 〉1 V was demonstrated in 45/94 (48%) ventricular leads (mean threshold 1.5 ± 0.3 V). This declined rapidly to 0.9 ± 0.3 V at 4 minutes (P 〈 0.01), 0.7 ± 0.3 V at 10 minutes (P 〈 0.01), and 0.6 ± 0.3 V at day 1 (P 〈 0.01). At day 1, 43/45 leads were 〈1 V. There were 79 atrial leads. An initial threshold of 〉1 V (mean 1.7 ± 0.6 V) was demonstrated in 41/79 (52%) leads falling significantly to 1.1 ± 0.5 V at 4 minutes (P 〈 0.01), 0.9 ± 0.4 V at 10 minutes (P 〈 0.01), and 0.6 ± 0.2 V at day 1 (P 〈 0.01). At 10 minutes, 32 of 41 leads demonstrated a threshold of 〈1 V with all leads 〈1 V at day 1. Thresholds were maintained medium term. Conclusions: Active-fixation leads are commonly associated with initially high thresholds that fall rapidly. An initial threshold of 2 V should be provisionally accepted and retested at 4 minutes. The majority will have a threshold of 〈1 V the following day. A failure of a high threshold to decline at 4 minutes requires lead repositioning.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The use of dual chamber pacing in patients with atrioventricular block and paroxysmal Supraventricular tachyarrhythmias may present a clinical dilemma because of the rapid and erratic triggering of ventricular pacing. To avoid this, a variety of pacing methods have now been described, including the use of retriggerable atrial refractory periods or dual demand pacing. This review details the use, advantages, and limitations of this poorly understood algorithm referred to as “pseudo-mode switching.”
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Several large prospective randomized trials have demonstrated that anticoagulation with warfarin reduces the risk of thromboembolic stroke in high risk patients with chronic AF by approximately 70%. Large numbers of patients with permanent pacemakers have AF, and anticoagulation rates in this population have not been described. In a prospective analysis of 110 consecutive patients attending the pacemaker clinic of a large university hospital, we assessed the number of patients with AF and the proportion of these patients who were receiving anticoagulation to prevent thromboembolic stroke. Where necessary, temporary pacemaker reprogramming to low ventricular rates was utilized to facilitate the diagnosis of AF. Fifty-three of the 110 patients (48%) were diagnosed with AF, all of whom (100%) had accepted high risk factors for thromboembolic stroke. Only eight of the 53 (15%) had been anticoagulated with warfarin. Thirty-six of the 53 patients (68%) diagnosed with AF had no prior documented diagnosis of chronic AF, and the majority had no symptoms suggesting AF. A single lead II ECG was insufficient in 67 of the 110 patients (61%) to diagnose the underlying atrial rhythm; the remainder required 12-lead ECGs or temporary pacemaker reprogramming to low ventricular rates to diagnose the underlying atrial rhythm. AF is common in patients with permanent pacemakers. It is commonly asymptomatic, and anticoagulation is markedly underutilized in reducing stroke risk in these patients. Attention to the possibility of AF in paced patients should allow prompt diagnosis and allow both the initiation of anticoagulation in order to reduce thromboembolic stroke risk and consideration for cardioversion of AF to sinus rhythm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 27 (2004), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The autointrinsic conduction search (AICS) option, featured on some DDD pacemakers, performs periodic assessments of atrioventricular (AV) conduction capability during a single beat AV delay extension. Demonstration of ventricular conduction during the prolonged AV delay, permits ongoing AV delay extension if the patient's intrinsic conduction is preferred to ventricular pacing. A case is presented where the wide separation of atrial and ventricular pacing during the conduction search permitted retrograde ventriculoatrial conduction, precipitating pacemaker mediated tachycardia (PMT) on seven occasions in one patient. Two onset patterns are reported, both attributable to the AICS option. Recommendations for prevention strategies are made. (PACE 2004; 27[Pt. I]:824–826)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Tricuspid Annular Tachycardia. Introduction: Focal right atrial tachycardia (RAT) arising from the crista terminalis, para-Hisian, and coronary sinus os regions are well described. Less information exists regarding RAT arising from the nonseptal region of the tricuspid annulus (TA). Methods and Results: From a consecutive series of 64 patients who had undergone successful radiofrequency ablation (RFA) of 67 RATs, the characteristics of 9 (13%) patients (6 men; mean age 50 ± 20 years) with a TA focus were reviewed. The annular focus was localized to the inferoanterior TA in 7 and the superior TA in 2. Mean tachycardia cycle length was 371 ± 66 msec. Mean activation time at the site of successful RFA in 9 of 9 patients was −43 ± 11 msec. At 9.3 ± 5.6 months of follow-up, 1 of 9 patients had recurrent tachycardia successfully treated with repeat RFA. In 7 of 9 patients with RAT from the inferoanterior TA, the surface ECG P wave morphology was upright in aVL, inverted in III and V1, and either inverted or biphasic with an initial negative deflection from V2 to V6. Conclusion: The TA is an important site of origin of RAT. In the present study, the inferoanterior region of the TA was a preferential site of origin with resulting characteristic P wave morphology. Knowledge of this anatomic distribution and P wave morphology allows targeted mapping and may facilitate successful RFA.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 12 (2001), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Ablation of Focal Atrial Fibrillation. Introduction: Ablative therapy for atrial fibrillation (AF) by targeting initiating triggers, usually in or around the pulmonary veins, has been reported by several centers. Evidence for an overall improvement in quality of life (QOL) and amelioration of symptoms is lacking. Methods and Results: Seventy-one patients undergoing attempted ablation of focal AF were followed for 60 ± 33 weeks. QOL and symptom questionnaires were completed 1 month before and 6 months after electrophysiologic study. Twenty-three patients (32%) underwent electrophysiologic mapping but no ablation because of either insufficient or multifocal ectopy; the other 48 patients (68%) underwent attempted ablation. Sixteen of 48 patients (33%) undergoing ablation, or 16 (23%) of 71 on an intention to-treat basis, were found at last follow-up to have persistent sinus rhythm without antiarrhythmic drugs. Patients who underwent mapping without ablation reported no improvements in any QOL or symptom score, whereas patients who had long-term successful ablation had significant improvements in all six QOL measures. Interestingly, patients who developed AF recurrence after ablation still reported significant improvements in 4 of 6 QOL measures. Four of 48 patients (8.3%) undergoing ablation developed pulmonary vein stenosis. Conclusion: Paroxysmal AF can be treated successfully in some patients by ablating initiating triggers in the pulmonary veins; however, in our experience the recurrence rate (32/48 [68%]) and risk of pulmonary vein stenosis (8%) after ablation are high. Patients with recurrent AF after ablation of focal AF triggers have significant improvement in QOL and symptoms compared with before ablation. Patients and their physicians should carefully balance the risks and benefits before considering ablation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2XG , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 15 (2004), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 14 (2003), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We report the case of an accessory pathway in a left inferoposterior diverticulum. The pathway masqueraded as a true left lateral pathway due to the direction of activation over a coronary sinus to left atrium connection. The patient had undergone four prior failed ablation attempts at other institutions using both a transseptal and retrograde approach. (J Cardiovasc Electrophysiol, Vol. 14, pp. 403-406, April 2003)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 12 (2001), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 14 (2003), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: Cavotricuspid isthmus (CTI) topography includes ridges, pouches, recesses, and trabeculations. These features may limit the success of radiofrequency ablation (RFA) of typical atrial flutter (AFL). The aim of this study was to assess the utility of phased-array intracardiac echocardiography (ICE) for imaging the CTI and monitoring RFA of AFL. Methods and Results: Fifteen patients (mean age 64 ± 9 years) underwent ICE assessment (imaging frequency 7.5–10 MHz) before and after RFA of AFL. The ICE catheter was positioned at the inferior vena cava-right atrial junction and the following parameters were measured: (1) CTI length from the tricuspid valve to the eustachian ridge; (2) extent of CTI pouching; and (3) thickness pre/post RFA of the anterior, mid, and posterior CTI. CTI length was 35 ± 6 mm at end-ventricular systole but shorter (30 ± 6 mm) and more pouched at end-ventricular diastole (P = 0.02) . A pouch or recess was seen in 11 of 15 patients (mean depth6 ± 2 mm). The septal CTI was more pouched than the lateral CTI, but the latter had more prominent trabeculations. Trabeculations were seen in 10 of 15 patients, and at these locations the CTI was4.6 ± 1 mmthick. Anterior, mid, and posterior CTI thickness pre-RFA was4.1 ± 0.8, 3.3 ± 0.5, and2.7 ± 0.9 mm, respectively (P 〈 0.001by analysis of variance). ICE guided RFA away from unfavorable CTI features (recesses/thick trabeculations). RFA applications created discrete CTI lesions that coalesced, forming diffuse CTI swelling. Post-RFA thickness was as follows: anterior4.8 ± 0.8 mm (P = NSvs pre); mid3.8 ± 0.8 mm (P = 0.05 vs pre); and posterior3.8 ± 0.8 mm (P = 0.02 vs pre). Conclusion: Phased-array ICE permits novel real-time CTI imaging with excellent endocardial resolution and may facilitate RFA of AFL. (J Cardiovasc Electrophysiol, Vol. 14, pp. 591-597, June 2003)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...