  • 1
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: Recent trials have demonstrated benefit of prophylactic defibrillator (ICD) implantation compared to conventional treatment in high-risk patients. However, many patients have rare or no sustained arrhythmias following implantation. Our study addresses the question, whether patients with prophylactic defibrillator implantation have a lower risk for life-threatening ventricular tachycardia (VT) or ventricular fibrillation (VF) compared to sudden cardiac death (SCD) survivors. Methods and Results: Over 7 years we enrolled 245 patients. Occurrence of spontaneous sustained VT/VF resulting in adequate ICD treatment was the endpoint. Incidence, type, and treatment of sustained arrhythmia in 43 previously asymptomatic ICD recipients (group B) were compared to data of 202 survivors of imminent SCD (group A). All patients had severely impaired left ventricular ejection fraction (〈45%). Group B patients had long runs (〉6 cycles, 〈30 s) of VT during Holter monitoring and inducible sustained arrhythmia. Incidence of rapid VT and VF (cycle length 〈240 ms/heart rate 〉250 bpm) after 4 years (35% in both groups, P = ns) and adequate defibrillator therapies (57% vs 55%, P = ns) were similar in both groups after univariate and multivariate analysis. Cumulative mortality tended to be lower in group B compared to group A, but the difference was not statistically significant. Conclusion: During long-term follow-up, incidence of sustained rapid ventricular arrhythmia in prophylactically treated patients is as high as that of SCD survivors. Benefit from defibrillator implantation for primary prevention (group B) appears to be comparable to that for survived cardiac arrest (group A).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 27 (2004), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This report describes the case of an 8-year-old boy with hypertrophic cardiomyopathy (HCM) who underwent ICD implantation for recurrent syncope. To avoid vascular complications and to minimize the surgical approach in this small child, a nonthoracotomy ICD system was chosen using a single subcutaneous array lead with only one finger, an abdominally placed active can, and epicardial dual chamber pacing and sensing electrodes. During an 8-month follow-up, DFT was confirmed and there were no ventricular tachycardia or complications. It appears to be a safe device for the prevention of sudden cardiac death in infants and small children. (PACE 2004; 27:117–119)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Atrial synchronous ventricular pacing seems to be the best pacing mode for patients with advanced AV block and impaired LV function. The long-term follow-up of single lead VDD pacing was studied in 33 patients with impaired LV function and compared to 42 patients with normal LV function. All patients received the same VDD lead and VDDR pacemaker. The lead model with 13-cm AV spacing between the atrial and ventricular electrode was implanted in 89% of the patients. Follow-ups were 1, 3, 6, and 12 months after implantation. The percentage of atrial sensing and the P wave amplitude were determined at each follow-up. Minimal P wave amplitude at implantation was 2.0 ± 1.4 mV in patients with impaired and 1.7 ± 0.9 mV with normal LV function (not significant). At the 12-month follow-up, 33 patients with normal and 23 patients with depressed LV function remained paced in the VDD mode. The remaining patients died in five (impaired LV function) and seven cases (normal LV function) or their pacemakers were programmed to the VVI/VVIR pacing mode in four (impaired LV function) and three cases (normal LV function). P wave amplitude did not differ in the two groups (e.g., at month 12: impaired: 1.17 ± 0.42 mV; normal: 1.09 ± 0.49 mV). The atrial sensitivity was programmed in most patients to sensitive settings with no differences between the two groups (e.g., at month 12: impaired: 0.13 ± 0.06 mV; normal: 0.13 ± 0.05 m V). The diagnostic counters indicated nearly permanent atrial sensing (e.g., at month 12: impaired: 99.3 ± 2.2%; normal: 99.0 ± 1.0 mV). In conclusions, single lead VDD pacing restored AV synchronous ventricular pacing in patients with normal and with impaired LV function indicating that it could be an alternative to DDD pacemakers, but not to dual-chamber pacing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...