Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Biochemistry 11 (1972), S. 130-136 
    ISSN: 1520-4995
    Source: ACS Legacy Archives
    Topics: Biology , Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of the American Water Resources Association 18 (1982), S. 0 
    ISSN: 1752-1688
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Geography
    Notes: : The detection of change in a hydrologic varaible, particularly water quality, is a current problem. A method is presented for testing whether there has been a shift in the mean of a hydrologic variable based on the well established bivariate normal distribution theory. In this technique, the dependent, or target, and the independent, or control, variables are formed as weighted linear combinations of the mean values at a number of locations in a selected target and control area. The weighting factors are determined based on a mathematical programming technique which minimizes the conditional coefficient of variation thereby minimizing the number of observations required to detect a change of a preselected magnitude in the mean of the target area. The result is a situation where a savings in the number of observations required to detect a change is a consequence of adding more stations: the space-time tradeoff. Two applications of the technique are presented, the first using electrical conductivity (EC) data from two sets of river basins and the second using EC data from a set of basins as the target variable and annual discharge as the control. The results indicate that a significant savings in time can be achieved by using this method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of the American Water Resources Association 35 (1999), S. 0 
    ISSN: 1752-1688
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Geography
    Notes: Several published BOD data sets are examined to show that approximately half of them are described best in the least squares sense by treating the BOD equation as being of the three-halves order instead of first order. A dissolved oxygen (DO) sag equation for a stream is developed in which the BOD is described as a three-halves order reaction. The time when the minimum DO concentration occurs is calculated numerically. The DO sag model applied to example problems shows that an increase in the BOD reaction rate constant results in a smaller minimum DO concentration and a decrease in the time to reach the minimum DO.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of the American Water Resources Association 23 (1987), S. 0 
    ISSN: 1752-1688
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Geography
    Notes: : An investigation was conducted to determine the feasibility of applying thermodilution technology to discharge measurements in small open channels. A series of tests were performed in which the time-temperature dilution curves were recorded and analyzed. The independent variables included the channel discharge, the injectate drop height, the volume of tracer, and the mixing distance. Flows ranged from 0.67 cfs to 2.45 cfs with Froude numbers less than 0.30.The results indicated that the thermodilution technique is a feasible method for discharge measurement. It was determined that a heat content, 1°, of 40°C provides a design criteria in which the mixing distance was related to the flow depth and discharge in a rectangular channel. An empirical expression was derived to determine the approximate mixing distance as a function of the flow depth.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    facet.materialart.
    Unknown
    New York : Periodicals Archive Online (PAO)
    Foreign Affairs. 48:2 (1970:Jan.) 285 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...