Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    135 Bedford Road, PO Box 418 , Armonk , NY 10504-0418 USA . : Blackwell Science Inc
    Journal of cardiac surgery 18 (2003), S. 0 
    ISSN: 1540-8191
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract  Purpose: The purpose is to present results of endovascular exclusion (stent-graft treatment) of aneurysms of the descending thoracic aorta both in elective cases and in emergencies. Methods: Indications for stent-graft treatment were dependent on multislice angio-CT evaluation revealing a proximal neck of at least 10 mm between the left common carotid artery and the onset of aneurysm. All stent grafts were inserted in the operating room; 43 transfemoral, 2 transiliac. The stent grafts used were Corvita, Stenford, Vanguard, AneuRx, Talent, and Excluder. Deployment was achieved under fluoroscopic control, endoleaks were checked for with D S A on the operating table and postoperatively by angio-CT. Long-term follow-up consisted of evaluation with angio-CT after 6 and 12 months, and from there on once a year and with plain chest X-rays. Follow-up was achieved in all patients. Results: Mean follow-up is 21 months (1–66); 30-day mortality is 3/45, no permanent neurologic deficit. Thirty patients were treated electively, 15 with contained rupture. Left subclavian artery overstenting proved to be necessary in 12 patients for proper proximal sealing of the aneurysm, type I endoleaks were observed in 10 patients, one early conversion, 7 proximal extension cuffs, one sealed spontaneously, one still at risk. Among patients where LSA had been overstented only one wanted a transposition, all others did well without left-hand ischemia or subclavian steal syndrome. Conclusion: Endovascular treatment is less invasive and has reasonable mortality and morbidity but is limited to well-defined morphologies. Mid-term results are promising but it has to be observed whether these will translate into long-term durability. (J Card Surg 2003; 18:367-374)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-3932
    Keywords: Schlüsselwörter Endovaskuläre Operationen ; Stents ; Aortenstentprothese ; Bauchaortenaneurysma ; Komplikationen ; Keywords Endovascular surgery ; Stents ; Aortic stent prostheses ; Aneurysm ; Abdominal aorta ; Complications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract  Intraoperative complications can be divided into three categories on the basis of the time of their occurrence: Group I – Problems associated with access; group II: introduction of the endovascular stent (a: release of the main segment, b: anchoring the second limb); and group III: incidence of primary endoleaks. The objective of the present study was to describe the management of these complications. In a group of 130 patients undergoing endovascular treatment of aneurysms of the abdominal aorta, a total of 31 complications occurred in 26 patients (20.0%). The most frequently encountered complication in each group and its respective management was as follows: Group I: Correction was performed using dilatation and retroperitoneal stretching as well as surgical shortening of the external iliac artery with interposition; group IIa: overstenting the renal arteries was corrected either by conversion or tugging at the endograft; group IIb: the guide wire or docking system could not be placed. Such cases were managed either through conversion or use of fresh systems; group III: such complications were treated with repeated stent placement, postoperative coil embolizations, or conversion. The endovascular therapy of aortic aneurysms is associated with intraoperative complications in 20% of cases. Adequate management helps to keep both morbidity and mortality rates low.
    Notes: Zusammenfassung  Intraoperative Komplikationen können je nach Zeitpunkt des Ereignisses in 3 Gruppen definiert werden: Gruppe I – Zugangsprobleme, Gruppe II – Einbringen des endovaskulären Stents (a: Absetzen des Hauptteils, b: Andocken des 2. Schenkels), Gruppe III – Inzidenz primärer Endoleaks. Zielsetzung dieser retrospektiven Studie war es, das Management zur Behebung dieser Komplikationen darzustellen. Von 130 Patienten mit endovaskulärer Ausschaltung eines Aortenaneurysmas traten bei 26 Patienten 31 intraoperative Komplikationen auf (20,0%). Die führenden Komplikationen in jeder Gruppe sowie das daraus resultierende Management waren: Gruppe I: Die Korrektur erfolgte durch Dilatation, retroperitoneale Streckung, Kürzungsoperation der A. iliaca externa und Interponat. Gruppe II a: Bei Überstentung der Nierenarterien erfolgte die Konversion oder Zug am Endograft. Gruppe II b: Führungsdraht oder Andocksystem können nicht platziert werden. Die Behebung erfolgte durch Konversion und Anwendung neuer Systeme. Gruppe III: Hier wurden erneute Stentplazierungen, postoperativer Coil-Embolisationen und Konversionen durchgeführt. Die endovaskuläre Therapie aortaler Aneurysmen birgt eine Rate intraoperativer Schwierigkeiten von 20%. In 3,8% der Fälle musste eine Konversion durchgeführt werden. Durch adäquates Management konnten die Letalität (1/26) und Morbidität jedoch gering gehalten werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-3932
    Keywords: Schlüsselwörter Femoropopliteale Verschlüsse ⋅ Endovaskulärer By-pass ⋅ Endopass ⋅ Ringsonden-TEA ; Key words Femoro-popliteal occlusive disease ⋅ Endovascular graft ⋅ Endopass ⋅ Ringstripper-TEA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Background: The implantation of a femoro-popliteal bypass graft represents the gold standard in the management of arteriosclerotic occlusive disease in the femoro-popliteal region. Application of interventional techniques has permitted the development of a novel, endovascular implantable bypass system. The device is placed within the lumen of the superficial femoral artery. The present study investigated the technical properties of the new system in cadavers, with subsequent evaluation of its application in humans. Methods: The endopass consists of a thin-wall polycarbourethane tube with a total length of 53 cm. The distal end is connected with a self-expanding stent prothesis 4 cm in length. Endovascular implantation is performed through a groin incision. Following antegrade ringstripper-TEA, the endopass is introduced into the femoral artery after placement of a guide wire. The proximal anastomosis is performed surgically. Results: The technical requirements and feasibility of the system were tested on 12 cadaver extremities. Implantation of the device proved technically successful in seven of eight extremities with significant occlusion of the superficial femoral artery. The most important problems included the complete ringstripper-TEA, the placement of the guide wire following the TEA, and the expansion of the endopass. Following approval by the ethics commission, the endopass was implanted in five patients between June 1997 and March 1998. In three patients, the endopass remained patent and has functioned well. One patient with poor vascular outflow suffered an early noncorrectable occlusion, while in the remaining case, perforation secondary to the ringstripper procedure forced us to abandon the attempt. Conclusion: Experience from the cadaver study and initial human applications confirm the feasibility of this method. Further development and methodological improvement, however, are necessary requiring additional, larger studies on patients.
    Notes: Zusammenfassung Fragestellung: Die Implantation eines femoropoplitealen Bypasses stellt heute den Goldstandard zur Behandlung der AVK bei Verschlußprozessen im femoropoplitealen Bereich dar. Durch Verwendung interventioneller Techniken konnte ein endovasculär implantierbares Bypassystem entwickelt werden. Im Rahmen einer Leichenstudie wurde die technische Funktionsfähigkeit des neuen Systems erprobt und danach die Evaluation in der humanen Anwendung begonnen. Methodik: Der Endopass besteht aus einer 53 cm langen, dünnwandigen Rohrprothese aus Polycarbourethan. Das distale Ende ist auf eine Länge von 4 cm mit einem selbstexpandierenden Stent armiert. Die Implantation erfolgt über eine Leisteninzision. Nach antegrader Ringsonden-TEA wird der Endopass über einem Führungsdraht in der A. femoralis superficialis plaziert. Die proximale Anastomose erfolgt chirurgisch. Ergebnisse: Die technische Durchführbarkeit und Funktionsfähigkeit wurde an 12 Leichenextremitäten erprobt. Bei 8 Extremitäten mit Verschlüssen der A. femoralis superficialis konnte das Verfahren in 7 Fällen technisch durchgeführt werden. Entscheidende Probleme sind die komplette Ringsonden-TEA, die Plazierung des Führungsdrahts nach TEA und die Entfaltung des Endopasses aus dem Introducer. Nach Änderung des Equipments und Freigabe der Anwendung durch die Ethikkommission wurde der Endopass von 6/97 bis 3/98 bisher bei 5 Patienten angewandt. Bei 3 Patienten ist der Endopass offen und zeigt eine gute Funktion. Ein Patient erlitt einen nicht korrigierbaren Frühverschluß bei schlechter Ausstrombahn und bei einem Patienten mußte das Verfahren bei Ringsondenperforation gewechselt werden. Schlußfolgerungen: Die Erfahrungen der Leichenstudie und der ersten humanen Anwendungen bestätigen die praktische Durchführbarkeit der Methode. Es sind jedoch weitere Entwicklungsarbeit und methodische Verbesserungen notwendig, die nur durch weitere Erfahrungen am Patienten gewonnen werden können.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Gefässchirurgie 5 (2000), S. 14-19 
    ISSN: 1434-3932
    Keywords: Schlüsselwörter Stentgraft ⋅ TALENT-System ⋅ Aortenaneurysma ; Key words Stent graft ⋅ TALENT device ⋅ Aortic aneurysm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Introduction The TALENT system has made it feasible for the first time to use endovascular stent placement in the treatment of infrarenal aneurysms of the abdominal aorta with neck diameters greater than 26 mm. The following paper presents the experience of 29 German vascular surgical centers using the TALENT system. Materials and Methods Between October 1996 and September 1997, a total of 123 aortic aneurysms in 122 patients were treated endovascularly. Ninety-five infrarenal aneurysms of the abdominal aorta were treated using bifurcated stents, while in 28 cases tube stents were implanted. In nine cases, tube stents were used to treat aneurysm of the thoracic aorta. A total of 111 patients (112 aneurysms) presented for follow-up. The average proximal diameter of the bifurcated stents in infrarenal aneurysms was 30 mm (range 24–36 mm), while the average iliac stent diameter was 14 mm (range: 10–20 mm). In tube stents, diameters ranged from 24–30 mm in abdominal stents and from 32–40 mm in thoracic stents, respectively. In this series, each stent was individually manufactured for the patient on the basis of findings from computed tomography (CT) and calibrated angiography. Results Endovascular treatment of aneurysms was successful technically in 96% of patients. During a follow-up period averaging 4.3 months, the following complications were observed: 5 perioperative death (4.1%), 4 conversions to open surgical therapy (3.3%), 7 endoleaks (5.7%), 2 stent dislocations, 2 iliac stent thromboses, 2 perforations of iliac arteries, 1 inguinal hematoma, and 1 inguinal infection. Conclusions These preliminary findings show that aneurysms with larger neck diameters are amenable to endovascular treatment. Despite the wide distribution of participating vascular surgery centers with varying degrees of experience and many first-time implantations, the results of the present multicenter study hardly differed from those reported in larger series in established institutions. Through the use of larger-diameter stents, up to 50% of all infrarenal aneurysms of the abdominal aorta may be possibly successfully treated using endovascular methods.
    Notes: Zusammenfassung Mit dem TALENT-System war erstmals die Ausschaltung infrarenaler Aneurysmen mit einem Halsdurchmesser größer 26 mm möglich. Es werden zusammengefaßt die Erfahrungen mit dem TALENT-System in 29 deutschen Zentren vorgestellt. Material und Methode: Von Oktober 1996 bis September 1997 wurden insgesamt 123 Aortenaneurysmen bei 122 Patienten endovaskulär behandelt; 95 infrarenale Bauchaortenaneurysmen wurden mittels Y-Stents und 28 mittels Tube-Stents ausgeschaltet. In 9 Fällen wurde ein thorakales Aortenaneurysma mit 〈\d〉 Tube-Stent therapiert. Insgesamt 111 Patienten (112 Aneurysmen) konnten in diesen Nachuntersuchungen erfaßt werden. Der durchschnittliche proximale Stentdurchmesser der Y-Stents bei infrarenalen Aortenaneurysmen betrug 30 (24–36) mm, der iliakale Stentdurchmesser betrug 14 (10–20) mm. Bei Tube-Stents in abdomineller Position betrug der Durchmesser 24–30 mm und bei thorakaler Verwendung 32–40 mm. Jeder Stent in dieser Serie wurde noch individuell für den betreffenden Patienten auf der Grundlage von CT und kalibrierter Angiographie angefertigt. Ergebnisse: Die Aneurysmaausschaltung war in 96% der Patienten technisch erfolgreich durchführbar. In einer mittleren Follow-up-Zeit von 4,3 Monaten traten folgende Komplikationen auf: 5 perioperative Todesfälle (4,1%), 4 Konventionen zur chirurgisch offenen Therapie (3,3%), 7 Endoleaks (5,7%), 2 Stentdislokationen, 2 iliakale Stentthrombosen, 2 Perforationen von Beckenarterien, 1 Leistenhämatom, 1 Leisteninfekt. Schlußfolgerungen: Diese Frühergebnisse zeigen, daß auch Aneurysmen mit größeren Halsdurchmessern endovaskulär gut therapiert werden können. Trotz der großen Streuung der teilnehmenden Zentren mit unterschiedlicher Erfahrung und vielen Erstimplantationen unterscheiden sich die hier erzielten Ergebnisse kaum von größeren Serien etablierter Zentren. Es scheint möglich, durch den Einsatz großlumiger Stents bis zu 50% aller infrarenalen Aortenaneurysmen endovaskulär zu behandeln.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...