Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Biophysics and Biomolecular Structure 22 (1993), S. 123-143 
    ISSN: 1056-8700
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0474
    Keywords: Schlüsselwörter Neugeborene ; Pulmonalatresie ; Interventionelle Perforation ; Ductus Stenting ; Key words Newborn ; Pulmonary atresia ; Interventional perforation ; Ductus stenting
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The surgical approach to the newborn with PAt-IVS is to establish an adequate source of pulmonary blood flow and, when possible, relieve right ventricular outflow obstruction. The selection of patients for pulmonary valvotomy, alone or in combination with a systemic-pulmonary arterial shunt, depends on the presence of a right-ventricular outflow tract and the adequacy of the right ventricular chamber. During the last years novel interventional approaches by heart catheterization have been developed, which allow perforation and subsequent balloon dilatation of an atretic pulmonary valve and/or stenting of the ductus arteriosus. We report our experience with these new interventional techniques in four neonates. In three patients highfrequency or mechanical perforation and subsequent balloon dilation of the atretic pulmonary valve was performed without complications. In one newborn with hypoplastic right ventricle and sinusoids with retrograde coronary perfusion the ductus arteriosus was stented via left arteria axillaris. Although no general conclusion can be drawn from our applications, interventional perforation of the pulmonary atresia and/or ductus stenting become an attractive interventional approach for the initial treatment of pulmonary atresia with intact ventricular septum.
    Notes: Zusammenfassung Die chirurgischen Möglichkeiten für Neugeborene mit Pulmonalatresie und intaktem Ventrikelseptum bestehen in der Etablierung eines adäquaten pulmonalen Blutflusses und, wenn möglich, in der Eröffnung des rechtsventrikulären Ausflußtrakts. Die Patientenauswahl für eine pulmonale Valvulotomie mit oder ohne Anlage eines systempulmonalarteriellen Shunts hängt vom Vorliegen eines rechtsventrikulären Ausflußtrakts und der Morphologie der rechten Kammer ab. In den letzten Jahren sind neue Herzkathetertechniken entwickelt worden, die eine Eröffnung und nachfolgende Ballondilatation der atretischen Klappe oder ein Stenting des Ductus arteriosus erlauben. Wir berichten über unsere Erfahrungen mit diesen neuen Interventionstechniken bei 4 Neugeborenen. Bei 3 Patienten wurde eine Hochfrequenz- bzw. mechanische Perforation und Ballondilatation der atretischen Pulmonalklappe ohne Komplikationen vorgenommen. Bei 1 Neugeborenen mit hypoplastischem rechtem Ventrikel und Sinusoiden mit retrograder Koronarperfusion wurde ein Stent in den Ductus arteriosus via A. axillaris implantiert. Obgleich das von uns gewählte Vorgehen keine generellen Schlußfolgerungen zuläßt, ist doch die interventionelle Perforation der Pulmonalatresie und/oder die Implantation eines Stents in den Ductus Botalli eine attraktive Alternative für die Primärbehandlung der Pulmonalatresie mit intaktem Ventrikelseptum.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1433-0474
    Keywords: Schlüsselwörter Hochfrequenzoszillationsbeatmung ; Hämodynamik ; Ebstein-Anomalie ; Gaumenspalte ; Key words High-frequency oscillatory ventilation ; Cardiopulmonary interactions ; Ebstein’s anomaly ; Cleft palate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Background: We report on the unsuccessful attempt to put a young patient with Ebstein’s anomaly on conventional ventilation for maxillofacial surgery. Reduced pulmonary bloodflow and cardiac output were followed by arterial hypotension and reduction of oxygen saturation. Spontaneous breathing without positive pressure ventilation normalized of the hemodynamic situation. Operation: Two years later, using a high-frequency oscillatory ventilator (SensorMedics 3100A), with relatively constant intrathoracic pressures and avoidance of high inspiratory pressures, the patient was adequately ventilated and oxygenated during the operation.
    Notes: Zusammenfassung Hintergrund: Es wird über den zunächst nicht erfolgreichen Versuch der konventionellen Beatmung während eines kieferchirurgischen Eingriffs bei einer Patientin mit Ebstein-Anomalie berichtet. Verminderter pulmonaler Blutfluß und entsprechend verminderter linksventrikulärer Auswurf führten zu einer arteriellen Hypotonie mit Sauerstoffsättigungsabfall. Unter Spontanatmung normalisierte sich der kritische Zustand rasch. Operation: Der Einsatz eines Hochfrequenzoszillationsbeatmungsgeräts (SensorMedics 3100A) mit gleichbleibendem mittlerem Atemwegsdruck und Vermeiden inspiratorischer Spitzendrücke ermöglichte 2 Jahre später eine adäquate Ventilation und Oxygenierung der Patientin, so daß die Operation durchgeführt werden konnte.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1433-0474
    Keywords: Schlüsselwörter Epikarde Elektroden ; Steroideluierende Elektroden ; Autocapture ; Frühgeborene ; Säugling ; Key words Epicardial pacing ; Steroid eluting electrodes ; Autocapture ; Infant
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary A small pulse-generator is important in prematures and young infants. Objectives: Analysis of our experience with the smallest currently available pacemaker in the pediatric age group. Patients and methods: We report about the pacemaker therapy in two premature babies with symptomatic complete congenital AV-block and about an 8 year old boy with congenital AV-block and palliation of complex congenital heart disease by total cavo pulmonary connection. The currently smallest pulse generator was implanted for the first time with a steroid eluting epicardial bipolar lead. Due to the ’autocapture algorithm’ a smaller battery can be used with the same life span as a normal sized pulse generator. Results: A stable capture threshold with a high amplitude of the evoked response signal and regular function of the ’autocapture’ algorithm was documented during a followup of up to 1 year. This algorithm has been used so far only with endocardial leads. Conclusion: This new combination seems promising for pacemaker therapy in small children.
    Notes: Zusammenfassung Fragestellung: Für Säuglinge und Frühgeborene ist eine geringe Größe des Schrittmacheraggregats besonders wichtig. Unsere bisherigen Erfahrungen mit dem kleinsten, z.Z. verfügbaren Pulsgenerator bei Kindern wurden analysiert und hier vorgestellt. Methode: Bei 2 Frühgeborenen mit symptomatischem kompletten AV-Block und einem 8jährigen Patienten mit kongenitalem AV-Block bei komplexen Vitium und Palliation mittels totaler kavopulmonaler Anastomose wurde der kleinste z.Z. verfügbare Pulsgenerator erstmals mit bipolaren, epikardialen steroideluierenden Elektroden implantiert. Dieser Schrittmacher arbeitet durch den Autocapture-Algorithmus besonders energiesparend, so daß trotz geringerer Batteriekapazität eine Laufzeit wie bei einem normal großen Aggregat erzielt werden kann. Ergebnisse: Bei einer niedrigen Reizschwelle und einer hohen Amplitude des evozierten Potentials fand sich eine normale Funktion des Autocapture-Algorithmus des Schrittmachers bei einer Nachbeobachtung bis zu 1 Jahr. Ein solches Aggregat wurde bislang nur mit endokardialen Elektroden eingesetzt. Schlußfolgerung: Diese Schrittmacher-Elektroden-Kombination erscheint als neues Therapiekonzept insbesondere für Säuglinge gut geeignet zu sein.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1435-2451
    Keywords: Valve surgery ; Valve reconstruction ; Transoesophageal echocardiography ; Klappenchirurgie ; AV-Klappenrekonstruktion ; Transoesophageale Echokardiographie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 30 Patienten mit Mitral- bzw. Tricuspidalklappenfehlem (6 Mitralstenosen bzw. 13 -insuffizienzen, 12 Tricuspidalinsuffizienzen) wurde intraoperativ am schlagenden Herzen mittels transoesophagealer Echokardiographie (TEE) der Erfolg einer operativen Rekonstruktion überprüft. 1 ml eines Echokontrastmittels wurde nach Bypassende in den jeweiligen Ventrikel injiziert. Anhand des Ausmasses der Regurgitation des Kontrastmittels in den betreffenden Vorhof konnte das Rekonstruktionsergebnis beurteilt werden. Bei allen Tricuspidalklappen sowie bei 16/19 Mitralklappen konnte eine erfolgreiche Rekonstruktion belegt werden. Die Aufdeckung einer massiven Mitralinsuffizienz bei 3/19 Patienten durch die TEE nach Rekonstruktionsversuch gab intraoperativ den Entscheid zum Klappenersatz.
    Notes: Summary In 30 patients (6 mitral stenoses, 13 mitral insufficiencies, 12 tricuspid insufficiencies) intraoperative transoesophageal contrast echocardiography (TEE) was performed to examine the valve function after AV valve reconstruction. In the beating heart 1 ml of contrast medium was injected into the ventricle to assess the success of valve reconstruction by the extent of regurgitation into the left or right atrium respectively. In all 12 patients successful tricuspid valve reconstruction was detected. In 16/19 cases with mitral valve repair successful reconstruction has been demonstrated. In another 3 patients severe mitral insufficiency after valve repair was detected by TEE, finally intraoperative decision for valve replacement was made.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...