Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: High temperature and very low threshold current operation of a separate confinement heterostructure (SCH) AlGaInP/GaxIn1−xP (x=0.43) strained multiple quantum well (SMQW) lasers has been achieved. Continuous wave (cw) operation was observed up to at least 150 °C with an output power of more than 7 mW, which is the highest cw operating temperature ever reported for devices operating in the visible wavelength region. The characteristic temperature between 20 and 80 °C was 130 K. The threshold current and threshold current density at 25 °C were 13.9 mA for a 5×160 μm device and 430 A/cm2 for a 80×770 μm device.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical & experimental allergy 16 (1986), S. 0 
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Following the promotion of anti-air pollution measures in steam power stations using crude oil, atmospheric concentrations of sulphur dioxide, nitrogen dioxide and suspended particulates have declined. These changes in atmospheric concentrations were accompanied by a decline in the prevalence of respiratory symptoms among schoolchildren living near the power stations. In analysing the correlation between air pollutant concentrations and the prevalence of respiratory symptoms, those with positive skin reactions to house dust extract (the positive group) showed a more significant correlation coefficient compared to those who had never had a positive skin reaction (the negative group). In addition, schoolchildren more heavily exposed to air pollutants showed the higher prevalence of respiratory symptoms than the others. With regard to the kind of air pollutants, both sulphur dioxide and nitrogen dioxide were more closely associated with the prevalence of respiratory symptoms than suspended particulates. This study has therefore demonstrated that the positive group is a useful population for monitoring the health effects associated with low-degree air pollution of gaseous agents.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗