Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    International journal of food science & technology 37 (2002), S. 0 
    ISSN: 1365-2621
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Summary There is a need for standard methods of testing domestic microwave ovens that relate to their reheating performance with chilled convenience meals. The investigations reported here have produced a simple procedure for comparing the three most important reheating characteristics of a domestic microwave oven: its ‘true’ power; heating variability; and repeatability. The tests are relatively simple to do, and require only a few additional items of equipment to those that a laboratory performing existing output power tests would already possess. Three identical tests are required: one with a liquid test material, one with a solid and one with a combination of the two components. One additional stage is done with the liquid test material. The data produced can be reduced to three numbers, which are measures of the true power, variability and repeatability of the oven. A further simple analysis, which weights the relative importance of each factor to the consumer, would produce a single value for the oven's relative reheating performance. Ovens with unusual or extreme performance characteristics can therefore be identified easily.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 22 (1950), S. 430-433 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    International journal of food science & technology 20 (1985), S. 0 
    ISSN: 1365-2621
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 664 (1992), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Materials Research 24 (1994), S. 359-408 
    ISSN: 0084-6600
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    International journal of food science & technology 20 (1985), S. 0 
    ISSN: 1365-2621
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: The effect of carbon dioxide chilling on drip, appearance and sarcomere length was investigated by cooling hot beef semifendinmu muscles from one end with solid carbon dioxide, thus obtaining a range of cooling rates covering carbon dioxide and conventional chilling within single muscles.Drip ranged from 3 to 12% and correlated with the chilling rate except where freezing and subsequent thawing occurred. Statistically significant differences in appearance were found but are commercially unimportant. Sarcomere length and cooling rate were found to be unrelated but this may be due to limitations in the apparatus used.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    International journal of food science & technology 39 (2004), S. 0 
    ISSN: 1365-2621
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: The microwave heating characteristics of foods vary with temperature, chemical composition, physical state and geometry. The purpose of the food simulates reported in this paper is to provide heating loads that will enable reliable and reproducible characterization of the heating performance of microwave ovens (2.45 GHz), specifically when heating chilled convenience meals. An extensive literature search was done to identify food simulants that had been used to mimic the heating responses of foods when heated both conventionally and in microwave fields. Each prospective food simulant was initially assessed against a set of criteria that included ease of manufacture, stability and formability. Four meals were chosen to represent the range of chilled convenience meals available in the UK. Tests, using continuous fibre-optic temperature measurement during heating, indicated that the meals could be separated into two broad categories according to heating times, i.e. ‘slow’ and ‘fast’ responders. Food simulants were developed for the two food categories. A good match between food simulant and meal was achieved for the main indicators, i.e. temperatures at central and intermediate locations and weight loss. A close match (a difference of 2% between food simulant and meal) was achieved for the centre location, which is important, as this is often the coolest area in the meal after heating in domestic microwave ovens.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 31 (2004), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  The present study examines the effect of a GoldbonderTM on the adhesion between titanium and porcelain as measured by the strain energy release rate (G) associated with the interfacial fracture of porcelain and titanium. The influence of surface treatment of titanium prior to GoldbonderTM application was also examined. The porcelain side of the specimens was notched to the interface with a thin diamond saw, and then a pre-crack was made at the metal–porcelain interface by a special jig. The samples were subjected to a four-point bending test resulting in stable crack extension from which G was calculated. Both the cracked cross-section of interface and peeled fracture surface were examined with scanning electron microscope (SEM). The mean G values were 81·57 ± 10·34, 46·01 ± 14·83, and 15·98 ± 1·76 J m−2 for the sandblasted surface with the GoldbonderTM, polished surface with the GoldbonderTM, and sandblasted surface with the PastebonderTM, respectively. The G values revealed significant differences (P 〈 0·01) between GoldbonderTM and PastebonderTM, and between the sandblasted and polished surfaces with GoldbonderTM. The SEM photographs and elemental analysis showed that GoldbonderTM developed both chemical and mechanical bonding to titanium and porcelain.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 32 (2005), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  The present study examines the influence of a goldbonder and pre-heat treatment of the titanium on the adhesion of porcelain. Three groups of titanium substrates were given various heat treatments, namely; none, 200 ° and 600 °C, respectively before applying goldbonder. The surfaces of the titanium specimens following heat treatment were examined with an electron spectroscopy for chemical analysis (ESCA). The adhesion strength was measured by the strain energy release rate (G), which was proposed by Suansuwan N and Swain MV (Int J Prosthodont. 1999;12:547). After bonding porcelain onto titanium substrates with the aid of the goldbonder, the porcelain side of specimens was notched to the interface with a thin diamond saw. Then the samples were subject to a four-point bending test. Following fracture testing, specimens were examined with a scanning electron microscope (SEM) and SEM with energy-dispersive spectroscopic analysis (EDS). The mean G-values were 38·87, 28·64 and 16·33 J m−2, respectively. ESCA analysis showed the composition of aluminium of the surface of 600 °C pre-heat treatment became richer than that of the others. SEM images of the fracture surfaces showed that for the 600 °C pre-heat treatment fracture occurred within the oxidation layer on the titanium. High temperature pre-heat treatment prior to bonding significantly reduces porcelain bonded to titanium with the goldbonder. The Influence of GoldbonderTM and Pre-heat Treatment on the Adhesion of Titanium Alloy and Porcelain.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A reliable measurement of the thermal expansion coefficient (α) value is required to achieve a positive thermal mismatch between metal and porcelain for porcelain-fused to metal crowns. Heating rate and specimen conditions may significantly influence the α value and the effects of these factors were studied. Commercially pure cast titanium rods, ‘as cast’ and sandblasted, were heated at various conditions. According to this study, the discrepancy of α values between heating and cooling conditions was insignificant when the heating (cooling) rate was reduced to 1 °C min–1. It was revealed that α values obtained from 1 °C min–1 cooling rates should be utilized. Dental porcelain with an α value lower than 8·5 × 10–6 °C will be suitable for titanium-ceramic applications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗