Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 244 (1973), S. 303-304 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The apparatus was a vertically mounted electromagnetic solenoid, with a hemispherically-ended perspex indenter 3 mm in diameter attached rigidly to its core: weights were attached to the core above the solenoid. Specimens were mounted in a perspex bath containing Ringer's solution plus mycifradin ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 220 (1968), S. 1127-1128 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Fig. 1. Curves of nominal stress (load-original cross-sectional area) versus extension or all four layers of a specimen taken from a 60 ear old male. The prick lines were arallel to the load axis. Table 1. ULTIMATE TENSILE STRESS FOR TWO ORIENTATIONS Specimen Parallel Across (1) Female 67 160 47 ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Archives of orthopaedic and trauma surgery 92 (1978), S. 31-34 
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Häufigkeit von Lockerungen des femoralen Anteiles der ICLH-Knieprothese ist niedriger als die des tibialen Anteiles. Die Ursache dafür glaubte man in der Tatsache zu sehen, daß die Druckkräfte am distalen Femur höher sind als an der proximalen Tibia. Es konnte jedoch gezeigt werden, daß die Stärke des femoralen Anteiles durch Osteoporose, wie bei PCP, so stark gemindert werden kann, daß die Fixation der Prothese unzureichend wird.
    Notes: Summary The incidence of loosening of the femoral component of the ICLH knee has been found to be lower than that of the tibial component. This is thought to be due to the fact that the compressive strength of the distal femur has been found to be greater than that of the proximal tibia. It has further been shown that the strength of even the femur can be so reduced by the osteoporosis accompanying Rheumatoid Arthritis that it becomes insufficient for adequate prosthetic fixation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 13 (1975), S. 245-251 
    ISSN: 1741-0444
    Keywords: Joints ; Degeneration ; Cartilage ; Fatigue ; Stresses
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Nine cadaver human hips were loaded cyclically in a physiological direction and to maxima of about three times body weight. Deformations of the whole joint and of the cartilage only were measured. The tests were repeated after all cartilage had been removed. Hips with normal cartilage showed no permanent deformation after up to 2000 cycles of load, whereas hips with degenerate cartilage showed irrecoverable deformation in the bone. Loading after removal of cartilage produced permanent deformation, accompanied by fatigue cracks, in the bone of all joints. It is concluded that normal cartilage limits the stresses in subchondral bone to a safe level whereas degenerate cartilage does not.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 7 (1969), S. 347-348 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 9 (1971), S. 23-32 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Des expériences de fatigue du cantilever rotatoire ont été entreprises sur des échantillons extraits longitudinalement du cortex du fémur humain. On a trouvé le rapport inverse habituel entre l'amplitude de la force et la vie de la fatigue; la vie médiane était 1,3×104 cycles à une amplitude de force de 12 200 1bf/in2 (84,1 MN/m2) et 4,6×106 cycles à 6750 1bf/in2 (46,6 MN/m2). Des arguments sont avancés qui suggèrent que ces résultats sont compatibles avec ce qui est connu sur les forces appliquées dans la vie et les occurrences cliniques des fractures par fatigue.
    Abstract: Zusammenfassung Es wurden rotierende, freitragende Ermüdungsteste an Spezimen durchgeführt, die längsweise von der Rinde des menschlichen Oberschenkelknochens entfernt worden waren. Es zeigte sich die normale, Inversbeziehung zwischen Belastungsbreite und Ermüdungsdauer: die mittlere Dauer war 1,3×104 Perioden bei einer Belastungsbreite von 12 200 1bf/in2 (84,1 MN/m)2 und 4,6×106 Perioden bei 6750 1bf/in2 (46,6 MN/m2). Es werden Schlussfolgerungen gezogen, nach welchen diese Resultate mit der erfahrungsgemässen, tatsächlichen Belastungsbreite und den klinischen Vorfällen von Ermüdungsfrakturen vergleichbar sind.
    Notes: Abstract Rotating cantileverfatigue tests were performed on specimens extracted longitudinally from the cortices of human femora. The usual inverse relationship between stress amplitude and fatigue life was found; the median life was 1·3×104 cycles at a stress amplitude of 12,200 1bf/in2 (84·1 MN/m2) and 4·6×106 cycles at 6750 1bf/in2 (46·6 MN/m2). Arguments are advanced which suggest that these results are compatible with what is known of the stresses applied in life and the clinical occurrence of fatigue fractures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 4 (1966), S. 411-411 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 4 (1966), S. 433-438 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire On étudie l'hypothèse suivant laquelle l'os tubulaire ou bien trabéculaire doit sa résistance à l'hydrodynamique. En se basant sur les renseignements fournis dans la littérature, on conclut que l'os tubulaire ne doit pas sa résistance à l'hydrodynamique. D'après une étude expérimentale décrite dans cet article, on conclut aussi que l'os trabéculaire ne doit pas sa résistance à l'hydrodynamique.
    Abstract: Zusammenfassung Die Hypothese, daß tubulärer oder trabekulärer Knochen hydraulisch verstärkt wird, wird untersucht. (1) Tubulärer Knochen. Aufgrund von Angaben aus der Literatur wird geschlossen, daß tubulärer Knochen nicht hydraulisch verstärkt wird. (2) Trabekulärer Knochen. Aufgrund von experimentellen Studien im Rahmen dieser Untersuchung wird geschlossen, daß auch trabekulärer Knochen nicht hydraulisch verstärkt wird.
    Notes: Abstract The hypothesis that bone, either tubular or trabecular, is hydraulically strengthened is examined. (1) Tubular bone. On the basis of information available in the literature, it is concluded that tubular bone is not hydraulically strengthened. (2) Trabecular bone. On the basis of an experimental study reported in this paper, it is concluded also that trabecular bone is not hydraulically strengthened.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 9 (1971), S. 619-629 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire (1) Les contraintes qui ont lieu dans l'os subchondral de la tête femorale du cadavre humain ont été mesurées lorsque la tête était soumise à une charge de grandeur et de direction physiologique. (2) Les contraintes étaient en tension autour de la circonférence de la tête femorale et en compression dans le plan de la charge appliquée. (3) Dans la tête femorale intacte la grandeur des contraintes était telle que la fracture par fatigue de l'os subchondral ne serait pas envisagée au cours de la vie. (4) Lorsqu'un défaut cylindrique de 13 mm de long et 10 mm de diamètre a été pratiqué au centre de la tête femorale, les contraintes mesurées dans l'os subchondral augmentaient invariablement et dans certaines têtes fémorales les efforts calculés étaient suffisamment grands pour causer une fracture par fatigue. (5) Il est conclu que des kystes se formant dans la tête fémorale en ostéo-arthrose peuvent normalement mener à un accroissement des tensions dans l'os subchondral avec une revascularisation conséquente possible du cartilage superficiel soit par une craquelure de fatigue soit du fait des changements vasculaires qui accompagnent la guérison d'une craquelure de fatigue incipiente. La probabilité de l'un ou de l'autre de ces évènements ne peut être estimée avec précision avec les renseignements disponibles, mais elle semble être faible.
    Abstract: Zusammenfassung (1) Die Spannungen, welche in dem subchondralen Knochen im Leichnam eines menschlichen Oberschenkelkopfes vorkommen, wurden gemessen, als der Kopf einer Belastung physiologischen Ausmasses und Richtungsweise unterworfen wurde. (2) Es ergaben sich Zugspannungen rund um die Oberfläche des Oberschenkelkopfes und Druckspannungen in der Ebene der angewandten Belastung. (3) In dem unbeschädigten Oberschenkelkopf war die Grösse der Spannungen derart, dass Ermüdungsbruch in dem subchondralen Knochen nicht zu Lebzeiten zu erwarten gewesen wäre. (4) Als eine zylindrische 13 mm lange Beschädigung von einem Durchmesser von 10 mm im Mittelpunkt des Schenkelkopfs durchgeführt wurde, stiegen die gemessenen Spannungen in dem subchondralen Knochen beständig an, und in einigen Oberschenkelköpfen waren die berechneten Spannungen gross genug, um wahrscheinlich Ermüdungsbruch hervorzurufen. (5) Man kommt zu dem Schluss, dass Zysten, die sich bei Osteoarthrose entwickeln, gewöhnlich eine Steigerung der Spannungen in dem subchondralen Knochen hervorrufen können, mit einer möglicherweise folgenden Gefässneubildung des darüberliegenden Knorpels, entweder durch Ermüdungsbruch oder aus Gründen von Gefässänderungen, welche die Heilung eines beginnenden Ermüdungsbruchs begleiten. Die Wahrscheinlichkeit dieser beiden Vorkommnisse kann auf Grund der vorhandenen Kenntnisse nicht genau bestimmt werden, sie erscheint aber gering.
    Notes: Abstract (1) The strains occurring in the subchondral bone of the cadaver human femoral head were measured when the head was subjected to a load of physiological magnitude and direction. (2) The strains were tensile around the circumference of the femoral head and compressive in the plane of the applied load. (3) In the intact femoral head the magnitude of the strains was such that fatigue fracture of the subchondral bone would not be expected to occur in life. (4) When a cylindrical defect 13 mm in length and 10 mm in diameter was made in the centre of the femoral head, the measured strains in the subchondral bone invariably rose, and in some femoral heads the calculated stresses were high enough to be likely to cause fatigue fracture. (5) It is concluded that cysts developing in the femoral head in osteoarthrosis may usually result in a rise in the stresses in the subchondral bone, with a possible consequent revascularization of the overlying cartilage either via a fatigue crack or by reason of the vascular changes accompanying the healing of an incipient fatigue crack. The probability of either of these events cannot be assessed accurately with the information available, but it appears to be low.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 16 (1978), S. 113-115 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...